Carrier 50HQ User Manual

Browse online or download User Manual for Heat pumps Carrier 50HQ. Carrier 50HQ Product data

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Copyright 2010 Carrier Corporation Form 50HQP-1PD
Single-package horizontally mounted
water source heat pumps with elec-
tronic controls.
Puron
®
refrigerant (R-410A)
Performance certified to AHRI/ISO/
ASHRAE 13256-1
Wide application use with an
entering water operating
temperature range of 20 F to 110 F
Dual refrigerant circuits for 2-stage
operation
High-efficiency scroll compressors
Thermostatic expansion valve (TXV)
provides efficient and reliable
refrigerant flow
High-static capability available
Available mute package for quiet
operation
Available low temperature insulation
to prevent condensation
Easy service access
Flexible and reliable controls
accommodate all systems (LON and
PremierLink™ controls)
Features/Benefits
Carrier’s Aquazone™ large
capacity units offer low cost,
energy efficient solutions for
all challenging water source
heat pump applications.
Operating efficiency
Carrier’s Aquazone horizontal water
source heat pumps (WSHPs) are
designed for quality and high perfor-
mance over a lifetime of operation.
Aquazone units offer cooling EERs
(Energy Efficiency Ratio) to 20.0 and
heating COPs (Coefficient of Perfor-
mance) to 5.0. Efficiencies stated are in
accordance with standard conditions
under ISO (International Organization
for Standardization) Standard 13256-1
and provide among the highest ratings
in the industry, exceeding ASHRAE
(American Society of Heating, Refriger-
ant and Air Conditioning Engineers)
90.1 Energy Standards.
AQUAZONE
50HQP072-120
Large Capacity Horizontal
Water Source Heat Pumps
with PURON
®
Refrigerant (R-410A)
6 to 10 Nominal Tons
Product
Data
TM
Page view 0
1 2 3 4 5 6 ... 33 34

Summary of Contents

Page 1 - Features/Benefits

Copyright 2010 Carrier Corporation Form 50HQP-1PDSingle-package horizontally mounted water source heat pumps with elec-tronic controls.• Puron® refrig

Page 2 - Table of contents

10(RIGHT)(LEFT)(BACK)(BACK)CONDENSAT EDRAINCONDENSATE DRAINC50HQP072-120NOTES:1. All dimensions in inches, unless indicated.2. Access is required for

Page 3 - Carrier’s PremierLink™ con

11I Determine the actual cooling and heatingloads at the desired dry bulb and wet bulbconditions.Assume cooling load at desired dry bulb 80 F andwet b

Page 4 - Model number nomenclature

12For example, using the Corrected Heat of Rejectionfrom the last step:If the units selected are not within 10% of the loadcalculations, review what e

Page 5 - AHRI/ISO capacity ratings

13CORRECTION FACTORS — ANTI-FREEZE LEGENDCORRECTION FACTORS — ENTERING AIRCORRECTION FACTORS — NOMINAL CFMNOTE: 400 CFM per ton is Nomina

Page 6 - Physical data

1450HQP0722400 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions are

Page 7 - Options and accessories

1550HQP0963200 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions are

Page 8

1650HQP1204000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions are

Page 9 - CARRIER AQUAZONE THERMOSTATS

1750HQP072 BLOWER DATA LEGENDNOTES:1. Units factory shipped with standard static sheave and drive at 2.5 turns open(

Page 10 - Dimensions

1850HQP096 BLOWER DATA LEGENDNOTES:1. Units factory shipped with standard static sheave and drive at 2.5 turns open(

Page 11 - Selection procedure

1950HQP120 BLOWER DATA LEGENDNOTES:1. Units factory shipped at ISO/AHRI setting with standard staticsheave and drive

Page 12 - Selection procedure (cont)

2High quality construction and testingAll units are manufactured to meet extensive quality control protocol from start to finish through an automated

Page 13 - Performance data

2050HQP120 BLOWER DATA (CONT) LEGENDNOTES:1. Units factory shipped at ISO/AHRI setting with standard staticsheave an

Page 14 - Performance data (cont)

2150HQP072-120 (STANDARD UNITS)50HQP072-120 (DUAL POINT UNITS) LEGEND*Time-delay fuse or HACR circuit breaker.UNIT50HQP

Page 15 - 50HQP096

22ThermostatWiringInsulated supply duct withat least one 90 deg elbowto reduce air noiseReturn AirSupply Air3/8” Threaded rodsUnit PowerDisconnectPowe

Page 16

23Complete CComplete C 2Complete C 1Complete CComplete C 2Complete C 1BC — Blower ContactorCB — Circuit BreakerCC — Compressor ContactorCO — Sensor, C

Page 17 - 50HQP072 BLOWER DATA

2450HQP072-120 WITH DELUXE D CONTROL (TYPICAL)See legend and notes on page 23.Deluxe DDeluxe DDeluxe DDeluxe DDeluxe D 2Deluxe D 2Deluxe D 1Deluxe D 1

Page 18

25YWOGRCAL1AL2ACRCMP1FANPWRHS1/EXH/RVSPREMIERLINKCRCOMPLETECCONTROLJ4J6J5J8J1PWRSPSALWCMPSAFETTTY1GRCAL1CMP1FANPWRPREMIERLINKDELUXEDCONTROLJ4J8J1PWRCM

Page 19 - 50HQP120 BLOWER DATA

26Aquazone™ water source heat pump products are availablein a flexible, efficient array of models, which can be used inall types of water loop, ground

Page 20

27Vertical ground loop — This system is used in verticalborehole applications. This design is well suited for retrofitapplications when space is limit

Page 21 - Electrical data

28Acoustical design goals are desirable sound pressure lev-els within a given conditioned space and are representedby noise criteria (NC) curves. Nois

Page 22 - Typical piping and wiring

2920. If return air is drawn through a ceiling plenum, pro-vide an acoustically lined return duct elbow or “L”shaped boot at the WSHP to eliminate lin

Page 23 - Complete C 1

3compressor section from 3 sides. Additional panels are provided to access the blower and control box sec-tions.The blower housing assembly can be se

Page 24 - Deluxe D 1Deluxe D 1

30Commercial Horizontal Water Source Heat Pump UnitsHVAC Guide SpecificationsSize Range: 70,000 to 120,000 Btuh Cooling CapacityCarri

Page 25

31h. Unit shutdown on high or low water temper-ature (selectable for antifreeze solutions).i. Option to reset unit at thermostat or discon-nect. Fault

Page 26 - Application data

32I. Sound Attenuation Package (Mute Package):Consists of attenuation material that is applied tothe cabinet to reduce noise. Attenuating materialshal

Page 27 - Acoustical design

3312. Extended Range:Extended range units provide an insulated watercircuit for the coaxial coil and refrigerant circuitto prevent condensation, and t

Page 28 - Application data (cont)

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 3

Page 29 - Freeze protection

4Size – Nominal Tons072 –6096 –8120 –10Water Circuit Options- – None50HQP 096 K C C 5 - 1 1 -50HQP – Horizontal Large Ca

Page 30 - Guide specifications

550HQP072-120 UNITS LEGEND NOTES:1. Cooling capacities based upon 80.6 F db, 66.2 F wb entering airtemperature.2. Heating capacitie

Page 31

650HQP072-120 UNITS LEGEND *All units have grommet and spring compressor mountings, and 1/2-in.and 13/4-in. electrical knockouts.†Two-inch f

Page 32 - Guide specifications (cont)

7Factory-installed optionsCupronickel heat exchangers are available for highercorrosion protection for applications such as open tower,geothermal, etc

Page 33

8includes occupied comfort settings with lights on, unoccu-pied energy savings with lights off.Programmable 7-day flush-mount thermostat offers thesam

Page 34 - Ta b 6 a

9PREMIERLINK™ COMMUNICATING CONTROLCOOLHEATAUTOR5-DAY PROGRAMMABLE/NON-PROGRAMMABLEAUTOPmCOOLHEATCarrier®CARRIER AQUAZONE THERMOSTATS7-DAY PROGRAMMABL

Comments to this Manuals