Manufacturer reserves the right to discontinue,or change at any time, specifications or designs without notice and without incurring obligations.
Printed in Mexico 10-06 79BC560010-01_C
OWNER’S MANUAL
MIRACOOL™ GLASS DOOR MERCHANDISER
2000L
Sales Office:
P.O. Box 5932
Spartanburg, S.C. 29304-5932
Technical Service: 1-800-558-7627
Parts Order Fax: 1-800-262-9381
Page view 0
1 2 3 4 5 6 ... 13 14

Summary of Contents

Page 1 - OWNER’S MANUAL

Manufacturer reserves the right to discontinue,or change at any time, specifications or designs without notice and without incurring obligations. Pri

Page 2 - INSTALLATION

10 TABLE 3 – REFRIGERATION SYSTEM SERVICE AND ANALYSIS CHART REFRIGERATION SYSTEM MALFUNCTION POSSIBLE CAUSE SOLUTION 1. Line cord not plugged in.

Page 3

11 FIGURE 12 – WIRING DIAGRAM

Page 4 - LEVEL UNIT

12 MAINTENANCE LAMP REPLACEMENT DANGER Before servicing unit, disconnect electrical service. Failure to disconnect electrical service could result

Page 5 - INSTALL SHELVES

13 TABLE 4 –METHODS FOR CLEANING STAINLESS STEEL TASK CLEANING AGENT* METHOD OF APPLICATION EFFECT ON FINISH Routine Cleaning Soap, ammonia or de

Page 6 - START-UP

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Pr

Page 7 - INITIAL START-UP

2 CONTENTS Page GENERAL...2 UNIT INSPECTION ...2

Page 8 - SYSTEM SERVICE

3 FIGURE 1 - MIRACOOL™ BOTTLE COOLER UNIT COMPONENTS (MC2000H SHOWN)

Page 9

4 LEVEL UNIT To provide adequate condensate drainage and proper door alignment and operation of unit, the unit cabinet must be level. Leveling feet a

Page 10 - REFRIGERATION SYSTEM

5 INSTALL SHELVES Product shelves and a bag containing shelf support clips are packed inside the unit. Refer to Table 1 to verify quantity of shelves

Page 11

6 START-UP PRELIMINARY CHECKS BI-PIN FLUORESCENT LAMP INSTALLATION / VERIFICATION Before applying power to the unit, verify that all lamps have bee

Page 12 - MAINTENANCE

7 TABLE 2 – UNIT DATA UNIT MC2000H / MC2000S Voltage (V) Nominal 115 Range 105-125 Frequency (Hz) 60 Total Amps 11.3 Refrigerant Type R-134A Cha

Page 13

8 REFRIGERATION SYSTEM SERVICE COMPONENTS The Carrier Miracool™ refrigeration system consists of a hermetically sealed compressor and finned evaporat

Page 14

9 EVAPORATOR COMPARTMENT SERVICING DANGER Before servicing unit, disconnect electrical service. Failure to disconnect electrical service could r