Carrier GAPAA Instruction Manual

Browse online or download Instruction Manual for Air filters Carrier GAPAA. Carrier GAPAA Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
GAPAB
Infinity™ Air Purifier for Fan Coils
Sizes 1620, 2020 and 2420
Installation Instructions
NOTE: Read the entire instruction manual before starting the
install.
TABLE OF CONTENTS
PAGE
INTRODUCTION 1...................................
HOW IT WORKS 1...................................
SAFETY CONSIDERATIONS 1.........................
APPLICATION CONSIDERATIONS 2....................
INSTALLATION 3....................................
START--UP AND OPERATION 6........................
MAINTENANCE 6....................................
TROUBLESHOOTING 8...............................
SPECIFICATIONS AND DIMENSIONS 9.................
WARRANTY 11......................................
INTRODUCTION
Congratulations for selecting the Infinity Air Purifier for your
home comfort system! The Infinity Air Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Infinity Air Purifier is a cornerstone
of Carrier’s Healthy Home Solutions for providing healthier,
cleaner air in your home.
HOW IT WORKS
The Infinity Air Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Infinity Air Purifier treats
the entire air--stream through a state of the art, three--stage process,
exclusive to Carrier.
In stage one, the particles are electrically charged by a
precision--point ionization array as they enter the Infinity Air
Purifier.
In stage two, the charged particles are electrically attracted to the air
purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
The Infinity Air Purifier is CSA certified for shock and electrical
fire hazard only.
La Infinity Air Purifier certification CSA vise uniquement les
risques de choc electrique et.
A06377
Fig. 1 -- GAPAB Unit
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property
damage. Consult a qualified installer, service agency or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings and cautions
included in literature and attached to the unit. Consult local
building codes and the current edition of the National Electrical
Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. When you see this symbol
on
the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING,andCAUTION. These words are used with the
safety--alert symbol. DANGER identifies the most serious hazards,
which will result in severe personal injury or death. WARNING
signifies hazards, which could result in personal injury or death.
CAUTION is used to identify unsafe practices, which may result
in minor personal injury or product and property damage. NOTE
is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Installation Instructions

GAPABInfinity™ Air Purifier for Fan CoilsSizes 1620, 2020 and 2420Installation InstructionsNOTE: Read the entire instruction manual before starting th

Page 3 - Adapters (x4)

11 39004DP452 01/10 Limited Warranty for Air Purifier FOR WARRANTY SERVICE OR REPAIR: Contact the installer. You may find the installer’s name o

Page 4

12 39004DP452 01/10 WARRANTY CONDITIONS: 1. To obtain the longer warranty periods as shown in the table under original owner, for the original pu

Page 5

2PERSONAL INJURY HAZARDFailure to follow this caution may result in personal injury.Ozone in concentrations above 0.05 PPM may be hazardousto health.D

Page 6 - Maximizing Performance

3INSTALLATIONStep 1 — Check Infinity Air Purifier ComponentsPERSONAL INJURY HAZARDFailure to follow this caution may result in personal injury.Sheet m

Page 7 - Tip of point after cleaning

4A06392Fig. 6 -- Use of Return Duct AdaptersELECTRIC SHOCK AND UNIT DAMAGE HAZARDFailure to follow this warning could result in personal injuryor deat

Page 8 - TROUBLESHOOTING

5ELECTRICAL SHOCK HAZARDFailure to follow this warning could result in personalinjury or death.Before installing or servicing system, always turn off

Page 9 - SPECIFICATIONS AND DIMENSIONS

6START--UP AND OPERATIONChecking Air Purifier OperationELECTRICAL SHOCK AND HIGH VOLTAGEHAZARDFailure to follow this warning could result in personal

Page 10

7Step 5 — Slide out the enhancement module assembly and safetyscreen.PERSONAL INJURY HAZARDFailure to follow this caution may result in personal injur

Page 11 - 39004DP452

8TROUBLESHOOTINGSAFETY HAZARDFailure to follow this caution may result in personal injury orequipment damage.The following instructions are for use by

Page 12

9SPECIFICATIONS AND DIMENSIONSTable 1 – Specifications and DimensionsSPECIFICATIONS GAPABXCC1620 GAPABXCC2020 GAPABXCC2420Color Taupe Metallic Taupe M

Comments to this Manuals