Carrier AIR COOLED SPLIT SYSTEM 38AQS008 Specifications

Browse online or download Specifications for Heat pumps Carrier AIR COOLED SPLIT SYSTEM 38AQS008. Carrier AIR COOLED SPLIT SYSTEM 38AQS008 Specifications [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation, Start-Up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS .................1
INSTALLATION ............................1-9
Step 1 Complete Pre-Installation Checks ..1
UNCRATE UNIT
INSPECT SHIPMENT
CONSIDER SYSTEM REQUIREMENTS
Step 2 Rig and Mount the Unit ............2
RIGGING
MOUNTING
COMPRESSOR MOUNTING
Step 3 Complete Refrigerant Piping
Connections .............................2
SIZE REFRIGERANT LINES
FILTER DRIER AND MOISTURE INDICATOR
LIQUID LINE SOLENOID VALVE
SAFETY RELIEF
SUCTION PIPING AT INDOOR COIL AND
TXV SENSING BULB LOCATION
Step 4 Make Electrical Connections .......3
FIELD POWER SUPPLY
ACCESSORY ELECTRIC HEAT
FIELD CONTROL WIRING
START-UP ...............................10,11
Preliminary Checks ........................10
Evacuate and Dehydrate ...................10
Refrigerant Charge ........................ 10
Refrigerant Service Ports ..................10
Sequence of Operation ....................10
Checking Cooling and Heating Control
Operation ...............................11
Malfunction ...............................11
SERVICE .................................11-13
Cleaning ..................................11
Lubrication ................................11
Outdoor-Fan Adjustment ...................11
Compressor Removal ......................11
Cooling Mode Operation ...................12
Heating Mode Operation ...................12
TROUBLESHOOTING CHART ..............14,15
START-UP CHECKLIST ................CL-1,CL-2
SAFETY CONSIDERATIONS
Installing and servicing air-conditioning equipment can be
hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install or service air-conditioning equipment.
When working on air-conditioning equipment, observe pre-
cautions in literature and on tags and labels attached to unit.
Follow all safety codes. Wear safety glasses and work gloves.
Use quenching cloth for brazing operations. Have fire ex-
tinguisher available. Read these instructions thoroughly. Con-
sult local building codes and National Electrical Code U.S.A.
(NEC) for special installation requirements.
Before installing or servicing system, always turn off
main power to system. There may be more than one dis-
connect switch. Electrical shock can cause personal
injury.
INSTALLATION
The 38AQS008 unit uses a semi-hermetic compressor. See
Tables 1A and 1B for physical data.
The 38AQS008 is approved by Carrier for use only with
40RMQ008 fan cooling units. Use only approved far coils.
The 38AQS008 (60 Hz) is Underwriters’Laboratories (UL)
and Canadian Underwriters’ Laboratories (CUL) approved
for use with the 40RMQ008 fan coil only.
Step 1 Complete Pre-Installation Checks
UNCRATE UNIT (See Fig. 1) Remove unit packaging
except for the top skid assembly and wood bumpers, which
should be left in place until after unit is rigged into place.
INSPECT SHIPMENT File claim with shipping com-
pany if shipment is damaged or incomplete.
Fig. 1 38AQS008 Unit
38AQS008
Air-Cooled Split System Heat Pump
50/60 Hz
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 5a 5a
PC 111 Catalog No. 533-887 Printed in U.S.A. Form 38AQS-4SI Pg 1 6-95 Replaces: 38AQS-3SI
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - Service Instructions

Installation, Start-Up andService InstructionsCONTENTSPageSAFETY CONSIDERATIONS ...1INSTALLATION ...1-9Step 1 —

Page 2

START-UPPreliminary Checks1. Check that all internal wiring connections are tight andthat all barriers, covers, and panels are in place.2. Field elect

Page 3

Should room temperature continue to fall, circuit R-W ismade through second-stage thermostat bulb. If optional elec-tric heat package is used, a relay

Page 4 - Fig. 2 — Dimensions

5. Remove crankcase heater from compressor base.6. Remove compressor holddown bolts and lift compres-sor off basepan.7. Remove compressor from unit.8.

Page 5

Fig. 16 — Cooling Mode OperationFig. 17 — Heating Mode Operation13

Page 6

TROUBLESHOOTING CHART, COOLING CYCLELEGENDTXV — Thermostatic Expansion Valve14

Page 7 - Table 4 — Electrical Data

TROUBLESHOOTING CHART, HEATING CYCLELEGENDN.C. — Normally Closed15

Page 10

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Page 11

START-UP CHECKLISTA. Preliminary InformationOUTDOOR: MODEL NO. SERIAL NO.INDOOR: AIR HANDLER MANUFACTURERMODEL NO. SERIAL NO.ADDITIONAL ACCESSORIESB.

Page 12

Table 1A — Physical Data (English)UNIT 38AQS008 60 Hz 50 HzOPERATING WEIGHT (lb)Aluminum Coils (Standard) 540 594Copper Coils (Optional) 608 662RIGGIN

Page 13

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Page 14

Table 2 — Refrigerant Piping SizesLINEAR LENGTH OF PIPING — ft (m)UNIT38AQS0-25(0-7.6)25-50(7.6-15.2)50-75(15.2-22.9)75-100(22.9-30.5)Line Size (in. O

Page 15 - N.C. — Normally Closed

UNIT38AQS008UNITW/ALUMINUM COILUNITW/COPPER COILWEIGHT CHART (WITH ALUMINUM COIL) WEIGHT CHART (WITH COPPER COIL)Std Unit Corner W Corner X Corner Y C

Page 16

All field wiring must comply with NEC (U.S.A.) and lo-cal requirements.Install field wiring as follows:1. Install conduit through side panel openings.2.

Page 17

LEGENDNEC — National Electrical CodeTXV — Thermostatic Expansion Valve*Accessory item.†Field supplied.NOTES:1. All piping must follow standard refrige

Page 18 - Ta b 5 a 5 a

Table 4 — Electrical DataUNIT38AQSNOMINAL VOLTAGE(V-Ph-Hz)VOLTAGE RANGE COMPRESSOR OFM POWER SUPPLY MINIMUM DISCONNECTMin Max RLA LRA FLA MCAMAX FUSE

Page 19

Table 5A — Accessory Electric Heater Data (60 Hz)UNIT40RMQHEATERPART NO.V-PH-Hz NOMINAL kWHEATERAMPSMCA* MOCP*008CAELHEAT001A00 240-3-60512.0 25.6 30C

Page 20 - C. Start-Up

2CORNERPOSTRACEWAY THERMOSTATFIELD CONNECTIONPOWER WIRINGCONNECTIONSFig. 6 — Fusible Plug LocationsLEGENDNOTE: The 8 o’clock position is shown above.F

Comments to this Manuals

No comments