Carrier AIRSTREAM 42BHC User Manual

Browse online or download User Manual for Household fans Carrier AIRSTREAM 42BHC. Carrier AIRSTREAM 42BHC Product data

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
© Carrier Corporation 2014 Form 42WKN-5PD
Hydronic ceiling cassette units offer:
6 chilled water cooling models to
properly match job
Optional electric heat or hot water
coil
Wall-mounted thermostat
Installation cost savings through
use of exisiting piping and/or wiring
Low noise level construction
Optional microprocessor based
controller with infrared transmitter
Features/Benefits
Ceiling cassette units make
each served area an
independent controlled
temperature zone to suit
diverse requirements.
Construction
Cases are constructed of lightweight
galvanized sheet steel with integral fan
mounting rails for added strength. Fire
resistant foam insulation (rated to
UL94 VO) is fitted internally to provide
both thermal and acoustic insulation.
The pearl-gray fascia is constructed
of high-impact polystyrene.
Chilled water coil
Units use large surface area coils posi-
tioned to optimize heat transfer and
airflow. Each coil is manufactured from
copper tubes with mechanically bond-
ed aluminum fins and is circuited from
headers to ensure low water pressure
drops.
Airstream™
42WKN08-36
Hydronic Ceiling Cassettes
50/60 Hz
3
/
4
to 3 Nominal Tons
(2.6 to 10.6 kW)
Product
Data
UNIT SIZES 08-12
UNIT SIZES 18-36
a42-4013
a42-4014
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Features/Benefits

© Carrier Corporation 2014 Form 42WKN-5PDHydronic ceiling cassette units offer:• 6 chilled water cooling models to properly match job• Optional electr

Page 2 - Table of contents

10CHILLED WATER UNIT COOLING CAPACITIESLEGEND NOTES:1. All duties based on high fan speed except where stated otherwise.2. Cooling capacities are gros

Page 3 - Physical data

11CHILLED WATER UNIT — TWO-PIPE CHANGEOVER HEATING CAPACITIESLEGENDNOTES:1. All duties based on high fan speed except where stated otherwise.2. Pressu

Page 4 - Options and accessories

12LEGEND*Standard unit fitted with optional electric heating elements. Availablewith 208/220/230-v model units only.Typical wiring schematicNOTE: Refe

Page 5

13Sequence of operationElectro-mechanical controls — A 24-v signal from thethermostat to terminal G supplies power to the blowermotor(s), condensate p

Page 6 - Dimensions

14Commercial Hydronic Cassette Fan CoilHVAC Guide SpecificationsSize Range: ¾ to 3 Tons7,000 to 36,000 Btuh,Nominal Cooling15,000 to 66,000 Btuh,Nomin

Page 7 - 42WKN18 AND 42WKN20 UNIT

153. Thermostat:The thermostat shall be commercial grade tocontrol unit operation and shall provide singlespeed fan capability. Automatic changeoverfr

Page 8 - Dimensions (cont)

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 1

Page 9

2FanThe backward-curved, centrifugal fans are statically and dynamically balanced for quiet operation. Fan impellers are made from either aluminu

Page 10 - Performance data

3LEGEND NOTES:1. Cooling capacity based on 80 F dry bulb/67 F wet bulb indoor anda 45 F entering/55 F leaving chilled water temperature.2. Heating cap

Page 11 - SOUND DATA

4Factory-installed optionsElectro-mechanical controls include an electro-mechanical controller with a 24-v transformer. The con-troller requires a 24-

Page 12 - Electrical data

5a total of four knockouts are available and are arranged inpairs along two of the unit sides (two per side).NOTE: On the 08,12 size units, it is reco

Page 13 - Controls

6Dimensions 25 3/1625 3/161 11/1622 1/211 1/42 3/410 11/1619 9/1619 1/2 12 9/161 7/1622 15/167/822 1/2 8 13/1611 5/164 11/163 11/162 5/8O5 3/166 1/25

Page 14 - Guide specifications

7 373711/1632 3/82 3/49 1/22 5/828 11/1631 3/828 9/16 12 9/161 13/164 5/868 5/81 5/85 5/167 3/42 3/42 3/44 7/84 15/1632 5/165 3/83 3/161 5/163 8 13/1

Page 15

8Dimensions (cont)AAVIEW A-A49 3/1637 2 1/432 3/84 3/411 1/22 5/828 11/16 12 9/1628 9/16 1 7/843 1/27/8 8 13/1619 5/812 7/166 3/83 5/83 3/8364 5/87

Page 16 - Replaces: 42WKN-4PD

9I Determine job requirements.Given:Room Sensible Cooling Load . . . . . . . .8,200 BtuhRoom Total Cooling Load . . . . . . . . .11,000 BtuhEntering-A