HEATING« COOLING
58DP,DR
Downflow Gas-Fired Natural-Draft Furnaces
58DP Series 150 and 160
58DR Series 130
Installation, Start-Up and Service Instructions
NOTE: Read the entire instructions before starting the
installation.
INTRODUCTION
Before installing the furnace, refer to “Procedures for
Natural-Draft Gas-Fired Furnaces” (packaged with the
equipment) for information concerning combustion, venting,
piping, and other standeird installation practices. Further
reference is made to the current edition of the National Fuel
Gas Code NFPA No. 54-1988/ANSI Z223.1-1988.
Reference should also be made to the regulations of the
serving gas supplier and the local building, heating, plumb
ing, or other codes in effect in the area in which the installa
tion is made.
SAFETY CONSIDERATIONS
Installation and servicing of heating equipment can be haz
ardous due to gas and electrical components. Only trained
and qualified personnel should install, repair, or service
heating equipment.
Untrained personnel can perform basic meuntenance func
tions such as cleaning and replacing air filters. AU other
operations must be performed by trained service personnel,
when working on heating equipment, observe precautions in
the literature, tags, and labels attached to or shipped with
the unit and other safety precautions that may apply.
Follow all safety codes, including NFPA No. 54/ANSI
Z223.1-1988, National Fuel Gas Code. Wear safety glasses
and work gloves. Have fire extinguisher available during
startup and adjustment procedures and service call.
Recomized safety information: This is the safety-alert sym
bol A. When you see this symbol on the furnace and in
instructions or manueils, be alert to the potential for per
sonal injury.
Understand the signal word—DANGER, WARNING, or
CAUTION. These words are used with the safety-alert sym
bol. DANGER identifies the most serious hazards which
will result in severe personal injury or death. WARNING
on the other hand could result in personal injury or death.
CAUTION is used to identify unsafe practices, which would
result in minor personal injury or product and property
damage.
Each furnace is shipped from the factory completely assem
bled with multispeed direct-drive blower and wired ready for
downflow indoor heating installation only. AU sizes feature
a printed-circuit board control center with easy-to-read, 24-
volt terminal strip to ensure proper connections.
Fig. 1—Model 58DP
Table 1—Clearances (In Inches)
(From Combustible Materials)
Sizes
050 075 thru 150
Sides—Single-Wall Vent
1 1
Type-B Double-Wall Vent 0
1
Back 0 0
Top of Plenum 1
1
Vent Connector—Single-Wall 6 6
Type-B Double-Wall
1 1
Front—Combustion Air* 6 6
Service
30 30
*The 6-inch front clearance is needed for combustion-air entry and
drafthood relief.
»■NOTE: The furnaces covered by these instructions are
design-certified for use with the vent damper specified on
the furnace rating plate. See instructions packaged with the
vent deunper for its installation.
A CAUTION
Application of this furnace should be indoors with spe
cial attention given to vent sizing and material, gas
input rate, air temperature rise, and unit sizing.
Improper installation or misapplication of the furnace
can require excessive servicing or cause premature com
ponent failure.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
'' I ^ PC 101 Catalog No. 565-873 Printed in U.S.A. Form 58DP,DR-4Si 5/89 Pg 1 Replaces: 58DP,DR-2SI
Tab I6al8a
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - A CAUTION

HEATING« COOLING58DP,DRDownflow Gas-Fired Natural-Draft Furnaces58DP Series 150 and 160 58DR Series 130Installation, Start-Up and Service Instructions

Page 2

Table 6—Trouble Analysis ChartA WARNINGTo avoid possibility of fixe, explosion, electric shock, personal injury or death, turn off gas

Page 3 - - FIELD24-VOLTWIRlNC

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Book

Page 4 - 314296-401 REV. A

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.I PC

Page 5 - 310471-402 REV. B

15. ^r'/8 THERMOSTAT CONN— -?>•o:aKNOCKOUT AUX GAS INLETTable 2—Dimensions (In Inches)SizeAD E Vent050-BA14^6 12"/,e 12”/,64075-AA17^21

Page 6

Fig. 5—Furnace, Plenum, and Base Installed on a Combustible FloorA CAUTIONDo not insteill furnace in a damp, corrosive, or contaminated atmosphere. M

Page 7 - ,-INSTALLATION

FUSED DISCONNECT SW ITCH (WHEN REQ'D)ILK SWITCHTRANCAP(WHEN USED)TO THERMOSTATBREAKAWAY TAB REMOVED WHEN CONNECTING VENT DAMPER (SEE INSTALLATION

Page 8 - Table 5—Speed Selector

FUSED DISCONNECT- D3-FU2D)ILK SWITC^l^BLKBLKWHT)JHTGRNGRN^AUX. J-BOXBLKTRANREDCWHEN USED)BRNCAPCWHEN USED)TO THERMOSTATBREAKAWAY TAB REMOVED WHEN CONN

Page 9 - Housing and Wheei Removed

B. Installation on a combustible floor1. Read Installation Instructions packaged with accessory combustible floor base.2. Cut eind frame h

Page 10 - A WARNING

3. Blower CircuitWith power through the solid-state time-delay circuit on printed-circuit board PCB and heat relay HFR, blower motor MT

Page 11 - Tab I6al8a

To change motor speed taps, remove the motor tap lead (See Table 5.) and relocate it on the desired terminal on the plugin terminal block/speed selec

Page 12

PILOTADJUSTMENT-IN LE' PRES TAPOUTLETPRESSURE TAPA87230Fig. 14—White Rodgers Model 36EA. Air FilterEach furnace accommodates two filters wh