WALL THERMOSTAT INSTALLATION
The following instructions apply to RC and RP units
only.
NOTE: Carrier thermostats are recommended. See
Accessories section.
INSTALL THERMOSTAT —
All remote control
units.
1. Check to be sure power to unit is disconnected.
2. Remove terminal board cover from control box
cover by removing screw (see Figure 12).
NOTE: Terminal connector can be removed and re-
placed to simplify thermostat wiring.
3. Connect wires from terminals on the thermostat
to terminals on chassis terminal board connector.
See Figures 13 and 14.
4. Reinstall cover.
5. Restore power to unit.
NOTE: Refer to thermostat installation instructions
for details on installing thermostat.
NOTE: Fan speed is user-selectable from the control
panel on the unit.
IMPORTANT: Only trained, qualified personnel
and service mechanics should install electrical
accessories on Carrier 52C and 52P series products
per Carrier’s installation instructions. Please con-
tact your local electrical contractor, dealer, or dis-
tributor for assistance.
TYPICAL
WALL
THERMOSTAT
R
G
Y
W
O
C
TERMINAL
BLOCK
SEE
NOTE #1
SEE
NOTE #2
R
G
Y
W
O
C
NOTES:
1. Use terminal “O” for heat pump connection only.
2. Terminal C (common) typically is only required for digital thermostats.
3. See table below for terminal descriptions.
FIGURE 13 — WIRING CONNECTIONS
TERMINAL DESIGNATION
R
24 VAC
G
Fan
Y
Compressor
W
Electric Heat
O
Reversing Valve
C
Common
FIGURE 14 — TERMINAL CONNECTOR
REMOVAL AND REPLACEMENT
POWER
CORD
THERMOSTAT
TERMINAL
COVER
SCREW
FAN SPEED
SELECTOR
SWITCH
FAN SPEED
HI
LO
FIGURE 12 — CONTROL BOX TERMINAL COVER