Carrier INFINITY 48XL-A User Manual

Browse online or download User Manual for Split-system air conditioners Carrier INFINITY 48XL-A. 48XL---09PD - County Heating & Air Conditioning Inc [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
48
X
L --- A
Infinity
®
15 SEER Sing le---Package d Air Co ndit ione r and
Gas F ur nace System with Puro n
®
(R---410A) Refrig er ant
Single Phase
2 --- 5 N o m i n a l To n s ( S i z e s 2 4 --- 6 0 )
Product Data
A09032
Fig. 1 -- Unit 48XL-- A
Single--Packaged Products with Energy -- Saving Features and
Puron
®
refrigerant.
S Direct Spark Ignition
S Up to 15.5 SEER
S Up to 12.0 EER
S Meets Energy Star requirements
S Up to 80.1% AFUE
S Low Sound Levels
S Variable--Speed Blower (Standard)
S Factory Installed TXV
S Stainless Steel Heat Exchanger
S Two Stage Cooling and Heating
S Advanced Dehumidification Feature
FEATURES/BENEFITS
One--piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
Puron
®
Environmentally-- Sound Refrigerant is Carrier’s unique
refrigerant designed to help protect the environment. Puron
refrigerant is an HFC refrigerant which does not contain chlorine
that can harm the ozone layer. Puron refrigerant is in service in
millions of systems proving highly reliable, environmentally sound
performance.
IdealHumidityt Technology featuring Infinityr control and
Variable--Speed Blower motor and two--stages of cooling and
heating provide greater comfort, humidity control, and energy
efficiency .
Innovative Unit Base Design
On the inside a high--tech composite material will not rust and
incorporates a sloped drain pan which improves drainage and helps
inhibit mold, algae and bacterial growth. On the outside metal base
rails provide added stability as well as easier handling and rigging.
Variable--Speed Blower motors provide better comfort and
energy efficiency. Economical constant airflow which provides
improved indoor air quality and more even temperatures from
room to room; and reduced indoor noise due to lower air velocity.
In addition, you’ll realize improved installation flexibility with 3
different airflow choices for best overall comfort.
Easy installation
Factory--assembled package is a compact, fully self--contained,
combination gas heating/electric cooling unit that is pre-- wired,
pre-- piped, and pre--charged for minimum installation expense.
These units are available in a variety of standard and optional
heating/cooling size combinations. Units are lightweight and install
easily on a rooftop or at ground level. The high tech composite unit
base eliminates rust problems associated with ground level
applications.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal
applications. Each unit is converted from horizontal to downflow
and includes horizontal duct covers. Downflow operation is
provided in the field to allow vertical ductwork connections. The
basepan seals on the bottom openings to ensure a positive seal in
the vertical airflow mode.
Efficient operation
High--efficiency design with SEERs (Seasonal Energy Efficiency
Ratio) of up to 15.5 and AFUE (Annual Fuel Utilization
Efficiency) ratings as high at 80.1%.
Energy -- saving, direct spark ignition saves gas by operating only
when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low--cost field installed kit
for propane conversion is available for all units.
48XLN-- A units are dedicated Low NOx units designed for
California installations. These models meet the California
maximum oxides of nitrogen (NOx) emissions requirement of 40
nanograms/joule or less as shipped from the factory and MUST be
installed in California Air Quality Management Districts or any
other location where a Low NOx rule exists.
Durable, dependable components
Compressors have two stages of cooling and are designed for high
efficiency . Each compressor is hermetically sealed against
contamination to help promote longer life and dependable
operation. Vibration isolation provides quiet operation.
Compressors have internal high--pressure and overcurrent
protection.
Monoport inshot burners produce precise air-- to--gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if ever,
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1 - Product Data

148XL --- AInfinity®15 SEER Sing le---Package d Air Co ndit ione r andGas F ur nace System with Puro n®(R---410A) Refrig er antSingle Phase2 --- 5 N o

Page 2

10ACCESSORY DIMENSIONSRETURN AIR SMALLBASE UNITSUPPLYAIRLARGEBASE UNITUNIT PLACEMENT ON COMMON CURBLARGE CURBSMALL OR LARGE BASE UNITSMALL/COMMON CURB

Page 3 - MODEL NUMBER NOMENCLATURE

11SELECTION PROCEDUREDetermine cooling and heating requirements at designconditions:Given:REQUIRED COOLING CAPACITY (TC) 34,500 BTUH...SENSIBLE HEA

Page 4 - AHRI* CAPACITIES

12PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL-- A24 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F

Page 5 - PHYSICAL DATA

13PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL-- A30 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F

Page 6 - PHYSICAL DATA (CONT)

14PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL-- A36 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F

Page 7 - FILTER RACK

15PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL-- A42 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F

Page 8 - 48XL--A24--30 UNIT DIMENSIONS

16PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL-- A48 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F

Page 9 - 48XL--A36--60 UNIT DIMENSIONS

17PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL-- A60 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F

Page 10 - ACCESSORY DIMENSIONS

18PERFORMANCE DATA (CONT)LEGENDBF— Bypass Factoredb— Entering Dry---BulbEwb — Entering Wet---BulbkW — Total Unit Power Inputldb— Leaving Dry---Bulblwb

Page 11 - SELECTION PROCEDURE

19PERFORMANCE DATA (CONT)High Altitude Compen sation: Natural GasNameplateInput, HighStage(Btu/hr)Rated Heating Input (Btu/hr), Natural Gas at Install

Page 12 - 48XL-- A24 Low Cool

2requires cleaning. All gas furnace components are accessible in onecompartment.Turbo--tubulart heat exchangers are constructed of 409stainless steel

Page 13 - 48XL-- A30 Low Cool

20PERFORMANCE DATA (CONT)Wet/Dry Coil Air Delivery (CFM)-- Low Stage208/230 VOLTUNITSIZESYSTEM SETTINGEXTERNAL STATIC PRESSURE (IN. W.C.)0.1 0.2 0.3 0

Page 14 - 48XL-- A36 Low Cool

21TYPICAL PIPING AND WIRINGROOFRETURN-AIRFLEXIBLE DUCTCEILINGCONCENTRIC DIFFUSER BOX(FIELD-SUPPLIED)SUPPLY-AIRFLEXIBLE DUCTROOF-MOUNTINGCURBA09226A092

Page 15 - 48XL-- A42 Low Cool

22APPLICATION DATACondensate trap — A 2 -- in. (51 mm) condensate trap must be fieldsupplied.Ductwork — Secure downflow dischargeductwork to roof curb

Page 16 - 48XL-- A48 Low Cool

23CONNECTION WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 040, 060, 090 kBtu/hrA10217C48XL--A

Page 17 - 48XL-- A60 Low Cool

24LADDER WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 040, 060, 090 kBtu /hrA10217L48XL--A

Page 18 - PERFORMANCE DATA (CONT)

25CONNECTION WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 115, 130 kBtu/hrA10219C48XL--A

Page 19

26LADDER WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 115, 130 kBtu/hrA10219L48XL--A

Page 20

27CONTROLSSequence of OperationCooling Operation—With a call for first stage cooling, the outdoorfan and low-- stage compressor are energized. If low-

Page 21 - TYPICAL PIPING AND WIRING

28GUIDE SPECIFICATIONSSINGLE-- PACKAGED AIR CONDITIONER AND GASFURNACE SYSTEM CONSTANT VOLUME APPLICATIONHVAC GUIDE SPECIFICATIONSSIZE RANGE: 2 TO 5 T

Page 22 - ELECTRICAL DATA

29GUIDE SPECIFICATIONS (CONT)M. Low NOx (Natural Gas only) Option (48XLN-- A Models):Shall provide NOx reduction to values below 40 nanograms/joule to

Page 23

3TABLE OF CONTENTSFEATURES/BENEFITS 1--2...MODEL NUMBER NOMENCLATU

Page 24

30Copyright 2010 Carrier Co rp. D 7310 W. Morris St. D Indianapoli s, IN 46231 Printed in U.S.A. Edition Date: 09/10Manufacturer reserves the right to

Page 25

4AHRI* CAPACITIESCooling Capacities, EfficienciesUnit 48XL--A Nominal TonsStandard CFM(High / Low Stage)Net CoolingCapacities (Btuh)(High / Low Stage)

Page 26

5PHYSICAL DATAUNIT SIZE 24040 24060 30040 30060 36060 36090 42060 42090NOMINAL COOLING CAPACITY (ton) 2 2 2 --- 1 / 2 2 --- 1 / 2 3 3 3 --- 1 / 2 3 --

Page 27 - CONTROLS

6PHYSICAL DATA (CONT)UNIT SIZE 48090 48115 48130 60090 60115 60130NOMINAL COOLING CAPACITY (ton) 4 4 4 5 5 5NOMINAL HEATING INPUT (Btu/hr) 90,000 115,

Page 28 - GUIDE SPECIFICATIONS

7OPTIONS AND ACCESSORIESITEM DESCRIPTIONFACTORYINSTALLEDOPTIONFIELDINSTALLEDACCESSORYCoil Options Base unit with tin plated indoor coil hairpins XCorp

Page 29 - GUIDE SPECIFICATIONS (CONT)

848XL--A24--30 UNIT DIMENSIONSA0952148XL--A

Page 30 - Catalog No: 48XL---09PD

948XL--A36--60 UNIT DIMENSIONSA0952248XL--A