7
STARTING THE UNIT -- STANDBY OPERATION
WARNING
Make sure the power plug is clean and dry before con-
necting to any power source.
Do not attempt to connect or remove power plug or
perform service and/or maintenance before ensuring
the unit RUN/STOP Switch is in the STOP position and
the I/O switch is in the “O” position.
BOX TEMPERATURE
AUTO START/STOP
I
UNIT DATA
PRETRIP
ALARM/FAULT
STANDBYBUZZER OFF
MAN
DEFROST
CITY
SPEED
ROAD
FUNCTION
ENTER
SETPOINT
O
i
-20 35° F
2. Connect unit to appropriate power source.
(See table on page 39)
4. Press Standby key.
1. Place the unit RUN/STOP switch in the
“STOP” position and the I/O switch in the “O”
position.
3. Place the unit RUN/STOP switch in the
“RUN” position and the I/O switch in the “I”
position.
Under normal circumstances this is all that is required to run the unit
in standby power. The unit will then perform a complete diagnostic
check on the microprocessor controller and start automatically.
Complete the Pre-Trip Inspection described in the previous section.