Carrier Supra 950 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
The new SUPRA Silent leads its class in low-noise emission,
and retains the temperature management and reliability of
conventional diesel technology.
Designed for 24/7 deliveries, even in noise-sensitive residential
areas, the Silent system is available on a range of 3 units:
SUPRA 950 Silent
SUPRA 850 Silent
SUPRA 750 Silent
in 3 different versions:
– Standard single-temperature
– Multi-temperature, for total flexibility in
multi-product deliveries
Nordic, with electrical & hot water heating, for
extreme low ambient temperatures.
SUPRA Silent
CMJKPMS072(11-03) 62-00000-00
Weight Dimensions Required opening
Ambient temperature at + 30 °C (per A.T.P. procedure)
SUPRA 950 Silent 10 770 6450 10 030 6190 2770
SUPRA 850 Silent 7810 4910 6400 4040 2500
SUPRA 750 Silent 6765 3825 5235 3045 2200
Operation (watts)
Road Standby
0°C-20°C0°C-20°C m
3
/h
Evaporator return
air temperature
SUPRA 950 596 625
Nordic 604 – 633 1995 x 940 x 684 1245 x 350 100 x 100
Mt° 561 – 590
SUPRA 850 455 – 477
Nordic 463 – 485 1823 x 856 x 629 1245 x 350 90 x 90
Mt° 443 – 465
SUPRA 750 423 – 445
Nordic 431 – 453 1823 x 856 x 629 1245 x 310 90 x 90
Mt° 405 – 427
Required opening
Single temp. Multi-temp.
Refrigeration capacity Airflow
500 CARRIER SERVICE STATIONS
in EUROPE, RUSSIA, MIDDLE EAST and AFRICA.
Specifications are subject to change
without notice.
Carrier Transicold Europe S.A.S. au capital de 16 090 700 euros
R.C.S. Pontoise B 410 041 776 - Code APE 518M - VAT: FR52410041776
The information contained in this document is not contractually binding,
and may not be reproduced without prior approval.
Printed in France (11-03) 62-00000-00
CARRIER TRANSICOLD EUROPE S.A.S.
10, boulevard de l’Oise
F-95031 CERGY PONTOISE CEDEX
Phone: +33 (0)1 34 43 48 00 - Fax: +33 (0)1 34 43 48 48
www.carrier-transicold-europe.com
SUPRA Silent has been the object of extensive acoustic research:
n Noise identified and eliminated at the source (new exhaust
mechanism, air filter, muffler, silentblock platform)
n Residual sound trapped inside the unit (new sound-absorbing
materials in doors, skins, improved air canalisation).
n
up to 90 m
3
n
up to 75 m
3
n
up to 66 m
3
Airflow
n Sound levels that are unheard of!
Noise levels are reduced by over 4dBA compared to previous
generation models. That means 60% less noise!
n New internal design features
The Silent system integrates a design exclusive to
Carrier Transicold.
n Exceptional reliability
Superior efficiency and enhanced product protection, even with
frequent door openings.
n With all the ease of use, service accessibility and
exceptional cooling capacities associated with the renowned
SUPRA range.
SUPRA Silent
Weight Dimensions
Kg mm
Page view 1
1 2

Comments to this Manuals

No comments