Copyright 1998 Carrier Corporation Form 58MSA-2PD
Product
Data
58MSA
4-Way Multipoise
Fixed-Capacity Condensing
Gas Furnace
Series 110
Input Capacities: 40,000 thru 120,000 Btuh
*High Efficiency and
Flexibility Designed to Meet
the Needs of New Homes
The model 58MSA combines high
efficiency with flexibility to meet the
changing needs of new home
construction. The unique 4-way,
multipoise design of the 58MSA
allows for installation in upflow,
downflow, horizontal left, and
horizontal right orientations,
meaning it is perfect for a variety
of installation applications. The
furnace is factory configured for
upflow application but can easily be
made ready for downflow or
horizontal installation.
Horizontal applications offer the
advantage of reduced space
requirements by locating the furnace
in an attic or crawlspace, freeing
space formerly dedicated to a furnace
or utility room.
The 58MSA is specifically
designed to meet the needs of home
builders and new home owners.
Home builders benefit from the
58MSA’s unmatched flexibility and
by building a reputation of using
quality appliances in homes. Home
owners benefit by energy savings
from 1 of the most important home
appliances.
The components of the 58MSA
represent the finest in the industry.
Hot surface ignition (HSI) and an
integrated control center provide
reliable and efficient ignition. The
inducer and inducer motor are unique
in that efficient operation is achieved
in any type of installation. Standard
PVC pipe is used to provide
combustion air to the furnace and
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Gas Furnace

Copyright 1998 Carrier Corporation Form 58MSA-2PD ProductData 58MSA4-Way MultipoiseFixed-Capacity CondensingGas Furnace Series 110Input Capacities: 4

Page 2 - BENEFITS

10Vent pipingMAXIMUM ALLOWABLE VENT PIPE (1 PIPE SYSTEM) LENGTH (FT)See notes on pg. 11.ALTITUDE ABOVE SEA LEVEL (FT) UNIT SIZEVENT PIPEDIA(IN.)NUMBER

Page 3 - Carrier accessories*

11MAXIMUM ALLOWABLE VENT PIPE (1 PIPE SYSTEM) LENGTH (FT) Continued * Wide radius elbow.† Vent sizing for Canadian installations above 4500 ft (1370m)

Page 4

12MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH INSULATIONIN WINTER DESIGN TEMPERATURE AMBIENT* * Pipe length (ft) specified for maximum vent pi

Page 5 - Physical data

13Clearance to combustiblesA97609323857-101 REV. C (LIT)MINIMUM INCHES CLEARANCETO COMBUSTIBLE CONSTRUCTION*Mimimum front clearance for service 30inch

Page 6 - Dimensions

14A96203A/C COILOUTDOOR UNITVENT PIPEHUMIDIFIERGAS-FIREDWATER HEATERELECTRONICAIR CLEANERAIRFLOWAIR INCOMBUSTION-AIR INLETA96202Typical installatio

Page 7 - CONDENSATE TRAP

15A96204ELECTRONICAIR CLEANERFURNACECONDENSATEDRAINREFRIGERATIONPIPINGAIR CONDITIONINGCOILAIRFLOWVENT PIPECOMBUSTION–AIR INLETAttic — Horizontal

Page 8 - 1075 — 3 1075 — 4 1075 — 3

Carrier Corporation • Syracuse, New York 13221 6-98Manufacturer reserves the right to discontinue, or change at any time, specifications or designs w

Page 9 - Typical wiring schematic

2 vent the exhaust outdoors. The primary and secondary heat exchangers are backed by a 20-year Limited Warranty.The 58MSA is a standard part of a qua

Page 10 - Vent piping

3 Model number nomenclature A93067 RETURN-AIRPLENUM Custom-made return-air plenum can be mounted on either side of the furnace. Two framedwashable fi

Page 11

4 NOTES: 1. The 58MSA Furnaces are for use with natural gas, but can be field-converted for propane gas with a factory-authorized and listed accessor

Page 12

5 Physical data * Capacity in accordance with U.S. Government DOE test procedures.† Gas input ratings are certified for elevations to 2000 ft. For el

Page 13 - TO COMBUSTIBLE CONSTRUCTION

6 Dimensions A98307 DIMENSIONS (In.) UNIT SIZE A D E040-08 17-1/2 15-7/8 16 040-12 17-1/2 15-7/8 16 060-08 17-1/2 15-7/8 16 060-12 17-1/2 15-7/8 16 0

Page 14 - Closet — Downflow Application

7 1⁄2 ODINDUCER HOUSINGDRAIN CONNECTION1⁄4 ODCOLLECTOR BOX TOTRAP RELIEF PORT5⁄8 ODCOLLECTOR BOXDRAIN CONNECTION1⁄2-IN. PVC OR CPVCSCREW HOLE F

Page 15

8 Performance data PSC — Permanent Split Capacitor EFFICIENCY * Capacity and AFUE in accordance with U.S. Government DOE test procedures.ICS — Isolat

Page 16 - SERVICE TRAINING

9Electrical data* Permissible limits of the voltage range at which the unit will operate satisfactorily.† Unit ampacity = 125% of largest operating co