HEATING A COOLING
38EN
Air-Cooled Condensing Units
THERMOSTAT SUBBASE
THERMOSTAT SUBBASE
ARRANGEMENT B-ONE TRANSFORMER
(COOLING AND ONE-STAGE HEATING)
THERMOSTAT SUBBASE
99TZ90036I20
(COOLING AND TWO-STAGE HEATING)
*IFR and IFM are located In furnace on heating-cooling applica
tions If accessory IFR is required for cooling-only applications,
locate (IFR) in fan coil
C — Contactor (12-va)
HC — Heating Control
IFM — Indoor Fan Motor
IFR — Indoor Fan Relay
Trans — Transformer
NOTE Refer to unit wiring label for wire colors: C to G andCto Y
connections
Field Splice
________
Field Wiring
________
Factory Wiring
Table 5 — 38EN Chargemaster® Charging
Chart (AccuRater™ System)
OUTDOOR
TEMP
(F)
EVAPORATOR TEMPERATURE (F)
21 I 25 I 28 I 31 I 34 I 37 I 4045 | 48
Suction Line Temperature ^)
60 32 40 51
62 30 38 39
64 28 37 47 60
66
27
35 45 57
68
34 43 54
67
70
32 41 52
64
72 31 39 50
61 72
74
30 37 48 58 69
76
29 36
46 56
66
78
27 35
44 54 63
75ii
80
26 33 42
52
61
72::
82
32 40 50 59 68
86
29 37
46
55 63 73
85
88
35
44
53 61
70 81
90
34
42 51
59 68
78 90
92
33
41
49 57
65 75
86
94
39 47
55 63 72
83
96
38
45 53 61
70 80
98
36
44
51 59
67 77
100
42
49 57
65 75
102
41
48 55
63
73
104 39 46
53 61
70
106 45 51
59 68
108 43
49 57
65
110 41
47
55 63
112
46
53 61
114
50
59
Example
Fig. 5 — Control Circuit Connections
Fig. 6 — 38EN Charging Chart
(AccuRater™ System)
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book II 14 PC 101 Catalog No 563-825 Printed inUS A Form38EN-3SI Pg 5 12-84 Replaces: 38EN-2SI