Carrier 38BYC User Manual

Browse online or download User Manual for Heat pumps Carrier 38BYC. 38BYC 018–060 60 Hertz Wiring Diagrams

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
38BYC
018–060
60 Hertz
Wiring Diagrams
Fig. 1—38BYC024-042 (31)
208-230v, 1 Phase, 60 Hertz
A99427
*CH
CONNECTION DIAGRAM
RED or BLK
BLK
YEL
COMP
BLK
CAP
YEL
BLU
*SR
*SC
OFM
BRN
BLK
BLK
208/230 1Ø
POWER
SUPPLY
INDOOR THERMOSTAT (NOTE #5)
FACTORY POWER WIRING
FIELD POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
CONDUCTOR ON CIRCUIT BOARD
COMPONENT CONNECTION
1/4-INCH QUICK CONNECT
TERMINALS
FIELD SPLICE
JUNCTION
CAP CAPACITOR (DUAL RUN)
*CH CRANKCASE HEATER
-LEGEND-
CONT
L1
11
21
SCHEMATIC DIAGRAM
(LADDER FORM)
EQUIP
GND
GND
EQUIP
*SR
*SC
H
COMP
C
F
CAP
OFM
CONT
23
L2
DR
OF2OF1
OO
W2
RR
DR
RVS
C
DFT
DFT
YY
DR
*LPS
*DTS
*HPS
C
T1
CTD
T2
CONT
C
NOTES:
1. COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT THERMAL
PROTECTION.
2. TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.) AND
LOCAL CODES.
3. N.E.C. CLASS 2, 24 V CIRCUIT, MIN. 40 VA REQUIRED.
4. USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT.
5. MUST USE THERMOSTAT AND SUB-BASE AS STATED IN PRE-SALE LITERATURE.
6. IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED SECONDARY,
CONNECT THE GROUNDED SIDE TO "C" ON THE CIRCUIT BOARD.
7. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE
SAME OR EQUIVALENT WIRE.
8. CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX FOR TIGHTNESS.
9. DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES HAVE BEEN OPENED.
10. WHEN DTS, LPS AND HPS ARE NOT REQUIRED, A JUMPER WILL BE INSTALLED
BETWEEN Y AND T1 ON THE DEFROST BOARD.
11. USE CONDUCTORS SUITABLE FOR AT LEAST 75°C (167°F).
90
50
30
FIELD SELECTED TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)
CONT
322851-101 REV. D
COMP COMPRESSOR
CTD COMPRESSOR TIME DELAY
CONT CONTACTOR
CB CIRCUIT BOARD
DFT DEFROST THERMOSTAT
DR DEFROST RELAY AND CIRCUITRY
*DTS DISCHARGE TEMP. SWITCH
*HPS HIGH PRESSURE SWITCH
*LPS LOW PRESSURE SWITCH
OFM OUTDOOR FAN MOTOR
RVS REVERSING VALVE SOLENOID
*SC START CAPACITOR
*SR START RELAY
RED or BLK
RED
L1
L2
RED
BRN
YEL
*CH
S
C
R
LOGIC
LOGIC
BLU
11
21
23 23
*LPS
*HPS
YEL
BLU or YEL
YEL
90
50
30
BLUBLK
*DTS
BLK
BRN
BLU or YEL
CYO
W2
REL
W3
G
RW2OYC
OF2
OF1
LOGIC
DFT
C
C
CB
BLK
YEL
ORN
WHT
RED
INDOOR UNIT
TERMINAL BLOCK
CYO
W2
REL G
T1
R
O
Y
YEL
BLK
T2
LOGI C
BLK
BRN
or
ORN
ORN
or
BLK
RVS
CTD
or
PNK
PNK
or
BLK
DFT
YEL
DR
1
2
5
S
C
R
23
* MAY BE FACTORY OR FIELD INSTALLED
JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE
HEAT CYCLE: 90 MIN. ACCELERATED TO 21 SEC.
50 MIN. ACCELERATED TO 12 SEC.
30 MIN. ACCELERATED TO 7 SEC.
DEFROST CYCLE: 10 MIN. ACCELERATED TO 2 SEC.
1
2
5
NOTE
THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE SHORT CYCLE PROTECTOR.
A FIVE MINUTE DELAY WILL OCCUR BETWEEN COMPRESSOR OFF/ON CYCLES.
YEL
SPEED
UP
SPEED
UP
Visit www.carrier.com
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 5a 5a
PC 101 Catalog No. 533-771 Printed in U.S.A. Form 38BYC-2W Pg 1 12-99 Replaces: 38BYC-1W
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Wiring Diagrams

38BYC018–06060 HertzWiring DiagramsFig. 1—38BYC024-042 (31)208-230v, 1 Phase, 60 HertzA99427*CHCONNECTION DIAGRAMRED or BLKBLKYELCOMPBLKCAPYELBLU*SR*S

Page 2 - -LEGEND

Fig. 2—38BYC018 (32), 048 (32) 208-230v, 1 Phase, 60 HertzA99431CAP*CH*CHSCOMPCONTCBDFTDR*DTS*HPS*LPSOFMRVS*SC*SR*ST* MAY BE FACTORY OR FIELD INSTALLE

Page 3

Fig. 3—38BYC060 (32) 208-230v, 1 Phase, 60 HertzA99428FACTORY POWER WIRINGFIELD POWER WIRINGFACTORY CONTROL WIRINGFIELD CONTROL WIRINGCONDUCTOR ON CIR

Page 4 - Tab 5a 5a

Copyright 1999 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 38byc2wManufacturer reserves the right to discontinue, or change at any tim