Downflow/Horizontal Induced-Draft
Gas Furnace
GENERAL
Before starting installation of this furnace, read
these instructions carefully and completely. After
installation is complete, remove the Energy Guide
tag from the furnace. Also read the Procedures for
Induced-Draft Gas-Fired Furnaces (packaged with
furnace) for important information concerning
combustion, venting, piping and other standard
installation practices. Further reference can be made
to the current edition of the American National
Standard Z223.1 National Fuel Gas Code.
The induced-draft vent system of this furnace is
designed to operate at zero or negative pressure at
the vent connector outlet. This furnace, therefore,
complies with the National Fuel Gas Code (NFPA
54-1980 or ANSI Z223.1-1980), Part 7.14.3.b. This
furnace is also listed by AGA for use with the type
B1 gas vent, as described in the National Fuel Gas
Code, Part 7.3.2.
Each furnace is shipped from the factory com
pletely assembled with multispeed direct-drive
blower, and wired ready for indoor heating installa
tion. All sizes feature a blower control center with
easy-to-read low-voltage terminal strip to ensure
proper connections.
The output capacity and any representations of
efficiency for this product are based on standard
Department of Energy test procedures. The installed
operation may vary, depending on installation,
weather and other factors.
( \l NON Ddik'I II Mall liiinaCL
111
a >.ono
^l^.c III i.iiiilaminali.d atmnMilu n. Xdlicu lo.ill
combustion and ciiculatmg air requirements
listed in Procedures foi Induced-Dratt (ias-
I ii..d liiiiiai.is ()h'^eI\l. all loi.al Lodes and
Fig. 1 — Furnace in Downflow Position
Fig. 2 — Furnace in Horizontal Position
The design of the downflow/horizontal (Fig. 1
and 2) gas-fired furnace is AGA certified for in
stallation on combustible flooring (with optional
floor base), in alcoves, attics, crawl spaces, base-
ments, closets or utility rooms. The design of this
furnace line is not AGA certified for installation in
mobile homes, recreation vehicles or outdoors.
Carrier Corporation 1984 Form 58DH-3SI
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - Gas Furnace

Carrier Corporation • Syracuse. N.Y. 13221aEPFICIENCYRATINGCERTIFIEDamaDownflow/Horizontal Induced-DraftGas FurnaceGENERALBefore starting installati

Page 2 - Table 2 — Dimensions (in.)

Fig. 18 — Cleaning Heat Exchanger Cell2) Insert brush end of cable into upper opening of cell and slowly rotate with drill. Do not force

Page 3

S -H THERMOSTAT „„WIRE ENTRY 13..-4"-2lllll HF"1o.. f__ ’ jr__Ì1" 7““'2S POWER ENTRYl^DIA KO.RH.GASENTRYM► ---i"=^ORIBOLTS

Page 4 - (See Table 5.)

Table 3 — Ratings and Performance*FURNACESIZETEMPRISERANGE (F)HEATING COOLINGAPPROX SHIP. WT (lb)INPUT(Btuh)CAPACITY(Btuht)Ext Static Pressure (in. w

Page 5

THorizontal Attic Installation — The Model 58DH furnace can be installed horizontally on either the left-hand or right-hand side. A typic

Page 6

Crawl Space Installation — The Model 58DH furnace can be installed horizontally with either the left-hand or right-hand side up. In

Page 7 - ADJUSTMENT CONTROL

See Fig. 12 for wiring diagram showing proper field high- and low-voltage wiring. Use separate fused branch electrical circuit contai

Page 8

Fig. 14 — Amp Draw Check With AmmeterBLOWER CONTROL CENTER — Furnace features a blower control center. This aids installer and serviceman

Page 9 - Blower Motor Wheel

START-UP AND ADJUSTMENTIn addition to the following information, refer to Procedures for Induced-Draft Gas-Fired Furnaces packaged with the

Page 10 - MMp cirui

3. Check electrical connections for tightness and controls for proper operation each heating season. Service as necessary.\\ \n wiili .m\