Carrier 38/40GRQ Owner's Manual

Browse online or download Owner's Manual for Split-system air conditioners Carrier 38/40GRQ. Carrier 38/40GRQ Owner's Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
40GRQ /
38GRQ
High --Wall Ductless Split S
yste
m
Sizes 09 to 18
Owner' s
Manual
NOTE TO EQUIPMENT OWNER:
Please read this Owners Information Manual carefully before installing and using this appliance
and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the
spaces provided. This information, along with the installation data and dealer contact information,
will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model #
Serial #
DEALERSHIP CONTACT INFORMATION
Company Name:
Address:
INSTALLATION INFO RMATION
Date Installed
Phone Number:
Technician Name:
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
2SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . .
SYSTEM REQUIREMENTS 2. . . . . . . . . . . . . . . . . . . . . . . . . . .
Wo
Model numbers
rking temperature range 3
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Instructions - programming remote and air conditioner 5. . . . . . .
Parts name 4. . . . . . . . . . . . . . . . . . . . . .
. .....................................
. .......
. . . . . . . . . . . . . . . . . . ..
Remote controller 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Lost or damaged remote control 16. . . . . . . . . . . . . . . . . . . . . . . . .
CLEANING AND MAINTENANCE 17. . . . . . . . . . . .
. . . . . . . .
Troubleshooting 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installatio
n diagram 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tools for installation
24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INDOOR UNIT INSTALLATION 26. . . . . . . . . . . . . . . . . . . . . .
OUTDOOR UNIT INSTALLATION FOR SINGLE ZONE APLICATIONS
(REFER TO THE 38GJ OWNER'S MANUAL FOR MULTIZONE)
31
Vacuum pumping
34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Leakage detection 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Checking installation 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing unit operation 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring connection pipe 36. . . . . . . . . . . . . . . . . . . . . . . . . . .
Pipe expanding method 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
the environmentally sound refrigerant
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Owner' s

40GRQ / 38GRQHigh --Wall Ductless Split SystemSizes 09 to 18 Owner' s Manual NOTE TO EQUIPMENT OWNER:Please read this Owner’s Info

Page 2 - SYSTEM REQUIREMENTS

REMOTE CONTROL FUNCTIONSFNote:no display9(horizontal louvers stopsat current position) buttonutton can turn on ( display " " icon) or

Page 3 - Model Number Reference

T-ON button “T-ON” button can set the time for timer on. After pressing this button, " " icon disappears and the word “ON"

Page 4 - Parts name

SLEEP button15Pressing this button can select Sleep 1, Sleep 2,Sleep 3, Sleep 4 or cancel Sleep circularly as below: cancelREMOTE CONTROL FUNCTIONSPre

Page 5 - Programming remote control

temperature curves. In Sleep 1 and Sleep 2, the air conditioner will run according to a group of presetting Sleep 3 - the sleep curve setting under DI

Page 6 - Remote controller

REMOTE CONTROL FUNCTIONS - COMBINATION KEYSX-FAN This function indicates moisture levels will blow away after unit stops to prevent mold.1.When X-FAN

Page 7 - Matching Remote Control

1.After initializing unit, press the ON/OFF button on remote control to turn on air conditioner.2.3. Press "+" or " - " button to

Page 8

Lost or damaged remote controlIf the remote control is lost or damaged, the air conditioner can be turned off directly from the unit. Lift the display

Page 9

CLEANING AND MAINTENANCE1234Open panel..WARNINGClean filter every three months. If dust accumulates quickly, clean filter more frequently.113°F (45°C)

Page 10 - REMOTE CONTROL FUNCTIONS

CLEANING AND MAINTENANCENotice for recovery1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit.2.

Page 11

TroubleshootingPlease identify problems and possible solutions for requesting maintenance assistance. If problem can not be resolved by following the

Page 12

3SAFETY CONSIDERATIONSInstalling, starting up, and servicing air-- conditioning equipmentcan be hazardous due to system pressures, electrical componen

Page 13

Troubleshooting burnt out? after stopping operation? Is remote control function setting correct? on the unit again. air switch or fuse.Air

Page 14 - COMBINATION KEYS

Problems Possible causes SolutionsFoul odorsSources of foul odors: furniture, cigarettes, etc.Air conditioner suddenly operates normally without repai

Page 15 - Operating unit

Note: If there are other error codes, please contact qualified professionals for service.WARNINGError codeE5E8E6U8H6C5F1F2TroubleshootingIt c

Page 16 - CLEANING AND MAINTENANCE

Installation diagramDrainage pipeAt least 8.2 ft (250cm)At least 4.9 ft (15cm)At least 1.64 ft (50cm)At least 1.64ft (50cm)At least 0.98 ft (30cm)At l

Page 17

1. There should be no obstruction near air inlet and air outlet.2. Select a location where the condensat- ion water can be dispersed easily and

Page 18

Grounding requirement The Air conditioner must be properly grounded to avoid electric shock.2. The yellow-green wire in air conditioner is groundin

Page 19 - Troubleshooting

INDOOR UNIT INSTALLATIONStep one: choosing installation locationStep two: install wall-mounting framerm it with the client.1. Hang the wall-mounting f

Page 20

1. Aim the pipe joint at the corresponding bellmouth.2. Pretightening the union nut with hand.3. Adjust the torque force by referring to the follow

Page 21

4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.Step six: install drain hoseINDOOR UNIT

Page 22

INDOOR UNIT INSTALLATIONNote:All wires of indoor unit and outdoor uniIf the length of power connection wire is insufficient, please contact the suppli

Page 23 - Installation diagram

Working temperature rangeIndoor side DB/WB( )°F/°C(°F/°C)Outdoor side DB/WBMaximum cooling115/75(46.1/23.9)Maximum heating80/-(26.7/-)75/64.9(2

Page 24 - INSTALLATION TIPS

INDOOR UNIT INSTALLATIONStep eight: bind up pipe1. Bind up the connection pipe, power cord and drain hose with the band.indoor unitgaspipeindoor a

Page 25 - Grounding requirement

OUTDOOR UNIT INSTALLATION FOR SINGLE ZONE APLICATIONS (REFER TO THE 38GJ OWNER'S MANUAL FOR MULTIZONE)CAUTION NOTE (select it acc

Page 26 - INDOOR UNIT INSTALLATION

OUTDOOR UNIT INSTALLATION FOR SINGLE ZONE APLICATIONS (REFER TO THE 38GJ OWNER'S MANUAL FOR MULTIZONE)Step four: connect indoor and outdoor pipes

Page 27

Step six: neaten the pipes1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pi

Page 28

Leakage detection6. Tighten the screw caps of valves and refrigerant charging vent.7. Reinstall the handle.1. With leakage detector: Check if there

Page 29

Checking installationTesting unit operationItems to be checked Possible problemThe unit may drop, shake or emit noise.Has the refrigerant leakage been

Page 30

1. Standard length of connection pipe4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe s

Page 31 - CAUTION NOTE

Additional refrigerant charging amount for R410A Liquid pipe(in/mm) Gas pipe(in/mm)__Cooling only(oz/ft (g/m)) Cooling and heating(oz/ft (g/m))0.2 oz

Page 32 - Indoor unit

Pipe expanding methodNote:Improper pipe expanding is the main cause of refrigerant leakage. Please expandthe pipe according to the following steps:A:

Page 34 - Vacuum pumping

air inletair outletConnection wireParts nameIndoor UnitOutdoor Unitair inletpanelfilterpower wirehorizontal louverremote controllerair outlettem.displ

Page 35 - Testing unit operation

Copyright 2014 Carrier Corporation S 7310 W. Morris St. S Indianapolis, IN 46231Manufacturer reserves the right to change, at any time, specifications

Page 36 - Configuring connection pipe

Instructions - programming remote and air conditionerProgramming remote controlSynch remote controls within 6.5ft (2m) from air conditioning unit. Wh

Page 37

Remote controllerIntroduction for icons on display screen326510111491613121587411 ON/OFF button2+/- button3Cool button4Heat button6 I FEEL button7up d

Page 38 - Pipe expanding method

Matching Remote ControlProgramming remote controlSynch remote controls within 6.5ft (2m) from air conditioning unit. While synching, the remote contr

Page 39

Press the FAN button to adjust the fan circulation speed: low( ), low medium( ), medium( ), medium high( ), high( ), supe

Page 40 - 66129916984

REMOTE CONTROL FUNCTIONS7 buttonno display(stops at current position)between simple swing mode and fixed swing mode. During switching time,“ ”

Comments to this Manuals

No comments