62-61107-02
18
CD10 BATT Battery voltage
CD11 SBY Standby (electric motor) hours
CD12 MOD V Future expansion
CD13 REV Software revision
CD14 SERL Serial number low
CD15 SERU Serial number upper
CD16 2RA Compartment 2 – return air temperature
CD17 3RA Compartment 3 – return air temperature
CD18 MHR1 Maintenance hour meter 1
CD19 MHR2 Maintenance hour meter 2
CD20 SON Switch on hour meter
*SAS and REM are options. SAS is displayed when the SUP PROBE function is
selected. REM is displayed when the REM PROBE function is selected.
7.8. To change a function
1. Press the FUNCTION CHANGE key (3.) until the function you want to change appears on the
display.
2. Press the ENTER key (17.).
3. Press the UP or DOWN ARROW key (2.) until the function setting you want appears on the
display.
4. Press the ENTER key (17.) to validate new setting.
FUNCTION PARAMETERS
CODE ENGLISH AVAILABLE SELECTIONS
FN0 DEFR Defrost interval 1.5, 3, 6 or 12hr
FN1 ON CITY SPEED Low speed only
FN1 OFF HIGH SPEED Low and high speed
FN2 OFF T Minimum Off-time 10, 20, 30, 45 or 90mn
FN3 ON T On-time 4 or 7 mn
FN4A REM PROBE
FN4B SUP PROBE
Controlling probe
FN5 F/C DEGREES F/C Standard unit selected (default C)
FN6 ON TIME STRT
FN6 OFF TEMP STRT
Maximum Off time
FN7 0 MOP SDT
FN7 -5 MOP -
FN7 +4 MOP +
Mop selection
FN10 ON AUTO OP
FN10 OFF MAN OP
Start mode
FN11 T RANGE Out of range (A=2°C / B=3°C / C=4°C)
CODES / ENGLISH Code or english display format
NORM / ADD GLOW Manual glow override. Normal of add 30 seconds
ALARM RST / CLR
Alarm RST = Alarm reset required
Alarm CLR = No alarm active
Selection in bold are factory settings.