Carrier GAS FURNACE 58MXA User Manual

Browse online or download User Manual for Water heaters & boilers Carrier GAS FURNACE 58MXA. Product Data - HVACpartners

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Copyright 1994 Carrier Corporation Form 58MXA-2PD
Product
Data
58MXA
Deluxe 4-Way Multipoise
Fixed-Capacity Condensing
Gas Furnace
Series 111
Input Capacities: 40,000 thru 120,000 Btuh
HEATING & COOLING
4-way Multipoise Design
Allows More Applications . . .
The model 58MXA is a must for your
product line. This high-efficiency
furnace allows more applications with
its reliable 4-way multipoise design.
The model 58MXA is available in 10
heat/airflow combinations and with the
4-way multipoise design can be
installed in upflow, downflow, or
horizontal positions covering up to 40
different applications. The furnace is
factory configured for upflow
application.
This versatile unit utilizes hot surface
ignition (HSI) which ignites the burners
directly. HSI eliminates gas waste that
typical continuous-pilot designs can
bring. Hot surface ignition provides
reliable start-up and operation.
Take a look at the control center on
the model 58MXA. Control of the
ignition, inducer, and blower operation
is all handled in 1 central printed circuit
board. The status indicator on the
control signals when a fault has
occurred and identifies where the
problem is. This, along with the
component test feature, makes the
58MXA one of the easiest gas furnaces
to troubleshoot.
High efficiency is achieved by
maximizing heat transfer. The model
58MXA uses 100% outdoor air for
combustion in a sealed combustion
system. The result is energy-saving
efficiency, 92% Annual Fuel Utilization
Efficiency (AFUE), and reduced
operational noise. The model 58MXA
is 1 of the quietest furnaces in the
industry.
A unique feature of this unit is the
patented polypropylene-laminated heat
exchanger. This secondary heat
exchanger ensures that all available heat
is properly transferred to the airstream
This document was created with FrameMaker 4.0.4
Page view 0
1 2 ... 14

Summary of Contents

Page 1 - Gas Furnace

Copyright 1994 Carrier Corporation Form 58MXA-2PD ProductData 58MXADeluxe 4-Way MultipoiseFixed-Capacity CondensingGas Furnace Series 111Input Capaci

Page 2 - HUM COM

10 Combustion-air and vent piping MAXIMUM ALLOWABLE PIPE LENGTH (FT) See notes on pg. 11. ALTITUDE ABOVE SEA LEVEL (FT) UNIT SIZE TERMINATION TYPE

Page 3 - Model number nomenclature

11 MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued * Disk usage—Unless otherwise specified, use perforated disk assembly (factory supplied in loose part

Page 4

12 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* * Pipe length (ft) specified for maximum ven

Page 5 - Clearance to combustibles

13 Typical installations Basement — Upflow Application A93063 Closet — Downflow Application A93064

Page 6 - Dimensions

Carrier Corporation • Syracuse, New York 13221 7-94 Manufacturer reserves the right to discontinue, or change at any time, specifications or desig

Page 7 - CONDENSATE TRAP

2 and throughout the home. Using the exclusive flow-through design, the secondary heat exchanger reduces the pressure drop in the furnace which leads

Page 8 - Performance data

3 Carrier accessories* * Factory authorized and field installed. Gas conversion kits are A.G.A. recognized.† For 16 and 20 sizes only and in upflow a

Page 9 - Typical wiring schematic

4 NOTES: 1. The 58MXA Furnaces are for use with natural gas, but can be field-converted for propane gas with a factory-authorized and listed accessor

Page 10 - See notes on pg. 11

5 Physical data * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4% for each 1000 ft above s

Page 11

6 CONCENTRIC VENT Dimensions DIMENSIONS (In.) UNIT SIZE A D E040-08 17-1/2 15-7/8 16 040-12 17-1/2 15-7/8 16 060-12 17-1/2 15-7/8 16 060-16 17-1/2

Page 12

7 CONDENSATE TRAP MEETS DOE RESIDENTIAL CONSERVATION SERVICESPROGRAM STANDARDS.Before purchasing this appliance, read importantenergy cost and effici

Page 13 - Typical installations

8 Performance data PSC—Permanent Split Capacitor EFFICIENCY * Capacity and AFUE in accordance with U.S. Government DOE test procedures.ICS—Isolated

Page 14 - Carrier Corporation

9 Electrical data * Length shown is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.† Permissible limits