Carrier EACB1614 Instruction Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4
AIR
CLEANER
OPENING
MAX 4"/102 mm DROP
PER LINEAL 12"/305mm
FURNACE
OPENING
AIR FLOW
FURNACE
AIR CLEANER
AIR FLOW
20
TRANSITION SECTION
o
A07682
Fig. 5 -- Transition to Unit
Turning Vanes
If the air cleaner is installed adjacent to a 90_ duct elbow, add
turning vanes (see Fig. 6) inside the duct to improve air
distribution across the face of the air cleaner . Failure to follow this
recommendation can reduce the efficiency of the Electronic Air
Cleaner .
TURNING VANES
C02038
Fig. 6 -- Turning Vanes
Select Location for Air Cleaner
Remember to select a location that is readily accessible for periodic
inspection and cleaning of this air cleaner. Allow a minimum of
24 (610 mm) clearance in front and 12 (305 mm) clearance
above the air cleaner for component removal and service space.
Planning the Installation
Application
Air cleaners are used in forced air heating cooling and ventilating
systems. The air cleaner should be installed in the system so that all
the system air is circulated through the air cleaner. The air cleaner
will only remove the airborne contaminants delivered to it.
Maximum performance is obtained when the system blower is set
for continuous operation.
Installation Requirements
The best location for the air cleaner is in the return air duct next to
the blower compartment. In this location, the blower motor and
cooling coils will be kept clean.
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this caution may result in reduced airflow
and potential operating problems.
Do not install the air cleaner in the discharge air duct.
CAUTION
!
Before installing the air cleaner, consider the application and type
of HVAC system present. See Fig. 7 for the most common types. If
a transition between the ductwork and air cleaner is required, refer
to section entitled Transitions and Fig. 5. The unit must be readily
accessible for periodic inspection and cleaning of the prefilters and
electronic cells to maintain maximum efficiency and trouble--free
operation.
Air Conditioning
The air cleaner should be installed upstream of the cooling coil.
This will keep the coil clean and reduce air conditioning coil
maintenance. Improved cooling efficiency is the result and directly
affects energy costs. A clean coil will reduce utility costs.
Humidifiers
An evaporative humidifier can be mounted upstream of the air
cleaner . It is best to install an atomizing humidifier downstream of
the air cleaner because hard water salt deposits and water droplets
may damage the air cleaner.
AIR FLOW
UPFLOW FURNACE
WITH TRANSITION
HORIZONTAL
DOWNFLOW
AIR FLOW
UPFLOW FURNACE
NO TRANSITION
UPFLOW FURNACE
WITH TURNING VANES
AIR FLOW
AIR FLOW AIR FLOW
A98179
Fig. 7 -- Typical Installations