Carrier 58CTA/CTX User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
Table1–Dimensions
FURNACE SIZE
A
CABINET
WIDTH
IN (mm)
D
SUPPLY ---AIR
WIDTH
IN (mm)
E
RETURN---AIR
WIDTH
IN (mm)
F
C.L. TOP AND
BOTTOM FLUE
COLLAR
IN (mm)
FLUE
COLLAR*
IN (mm)
SHIP WT
LB (KG)
FILT ER
MEDIA
CABINET
IN (mm)
045---08/024045 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9--- 5/16 (237) 4 (102) 104 (47) 16 (406)
045---12/036045 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9--- 5/16 (237) 4 (102) 107 (48) 16 (406)
070---08/024070 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9--- 5/16 (237) 4 (102) 111 (50) 16 (406)
070---12/036070 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9--- 5/16 (237) 4 (102) 115 (52) 16 (406)
070---16/048070 17--- 1/2 (445) 15--- 7/8 (403) 16 (406) 11--- 9/16 (294) 4 (102) 126 (57) 16 (406)
090---14/042090 17--- 1/2 (445) 15--- 7/8 (403) 16 (406) 11--- 9/16 (294) 4 (102) 127 (58) 16 (406)
090---16/048090 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 (102) 140 (64) 20 (508)
090---20/060090 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 (102) 146 (66) 20 (508)
110---12/036110 17--- 1/2 (445) 15--- 7/8 (403) 16 (406) 11--- 9/16 (294) 4 (102) 135 (61) 16 (406)
110---16/048110 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 (102) 146 (66) 20 (508)
110---22/066110 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 (102) 152 (69) 20 (508)
135---16/048135 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 (102) 149 (68) 20 (508)
135---22/066135 24--- 1/2 (622) 22--- 7/8 (581) 23 (584) 15--- 1/16 (383) 4 (102) 163 (74) 24 (610)
155---20/060155 24--- 1/2 (622) 22--- 7/8 (581) 23 (584) 15--- 1/16 (383) 4 (102) 170 (77) 24 (610)
* 5 ---in. or 6 ---in. (127 or 152 mm) vent connector may be required in some cases.
{ 135 and 155 size fur naces require 5---in. (127 mm) or larger vents. U se a 4 to 5 or 4 to 6---in. (102 to 127 or 102 to 152 mm) vent adapter between furna ce and
vent connector.
product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
1. Use only with type of gas approved for this furnace. Refer
to the furnace rating plate 2. Install this furnace only in a
2. Install this furnace only in a location and position as spe-
cified in the “Location” section of these instructions.
3. Provide adequate combustion and ventilation air to the
furnace space as specified in “Air for Combustion and
Ventilation section.
4. Combustion products must be discharged outdoors. Con-
nect this furnace to an approved vent system only, as spe-
cified in the “Venting section of these instructions.
5. Never test for gas leaks with an open flame. Use a com-
mercially available soap solution made specifically for the
detection of leaks to check all connections, as specified in
the “Gas Piping section.
6. Always install furnace to operate within the furnace’s in-
tended temperature--rise range with a duct system which
has an external static pressure within the allowable range,
as specified in the “Start--Up, Adjustments, and Safety
Check section. See furnace rating plate.
7. When a furnace is installed so that supply ducts carry air
circulated by the furnace to areas outside the space con-
taining the furnace, the return air shall also be handled by
duct(s) sealed to the furnace casing and terminating out-
side the space containing the furnace. See “Air Ducts” sec-
tion.
8. A gas--fired furnace for installation in a residential garage
must be installed as specified in the warning box in the
“Location” section.
9. The furnace may be used for construction heat provided
that the furnace installation and operation complies with
the first CAUTION in the LOCATION section of these in-
structions.
10. These Multipoise Gas--Fired Furnaces are CSA (formerly
A.G.A. and C.G.A.) design--certified for use with natural
and propane gases (see furnace rating plate) and for install-
ation in alcoves, attics, basements, closets, utility rooms,
crawlspaces, and garages. The furnace is factory--shipped
for use with natural gas. A CSA (A.G.A. and C.G.A.) lis-
ted accessory gas conversion kit is required to convert fur-
nace for use with propane gas.
11. See Fig. 2 for required clearances to combustible construc-
tion.
12. Maintain a 1--in. (25 mm) clearance from combustible ma-
terials to supply air ductwork for a distance of 36 inches
(914 mm) horizontally from the furnace. See NFPA 90B
or local code for further requirements.
13. These furnaces SHALL NOT be installed directly on car-
peting, tile, or any other combustible material other than
wood flooring. In downflow installations, factory access-
ory floor base MUST be used when installed on combust-
ible materials and wood flooring. Special base is not re-
quired when this furnace is installed on manufacturer’s
Coil Assembly Part No. CAR, CAP, CNRV, CNPV or
when Coil Box Part No. KCAKC is used. See Fig. 2 for
clearance to combustible construction information.
INTRODUCTION
The Series 130/D 4--way multipoise Category I fan--assisted
furnace is CSA (formerly A.G.A.. and C.G.A.) design--certified.
A Category I fan--assisted furnace is an appliance equipped with
an integral mechanical means to either draw or force products of
combustion through the combustion chamber and/or heat
exchanger. The furnace is factory--shipped for use with natural
gas. This furnace is not approved for installation in mobile
homes, recreational vehicles, or outdoors.
These furnaces shall not be installed directly on carpeting, tile, or
any other combustible material other than wood flooring. For
downflow installations, a factory accessory floor base must be
used when installed on combustible materials and wood flooring.
This special base is not required when this furnace is installed on
the manufacturers coil assembly, or when the manufacturer’s coil
box is used. See Fig. 2 for clearance to combustible material
information.
This furnace is designed for minimum continuous return--air
temperature of 60_F(16_C) db or intermittent operation down to
55_F(13_C) db such as when used with a night setback
thermostat. Return--air temperature must not exceed 80_F(27_C)
db. Failure to follow these return--air temperature limits may
affect reliability of heat exchangers, motors, and controls. (See
Fig. 3.)
For accessory installation details, refer to the applicable
instruction literature.
NOTE: Remove all shipping brackets and materials before
operating the furnace.
58CT
Page view 2