This symbol indicates a change since the last issue.
Index Page
SAFETY CONSIDERATIONS..................................................1-2
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE...........................................................................2
CARE AND MAINTENANCE..................................................2-7
Air Filter Arrangement..........................................................2-3
Blower Motor and Wheel......................................................3-4
Cleaning Heat Exchanger......................................................4-6
Electrical Controls and Wiring .............................................6-7
Troubleshooting...................................................................7-10
Unit Wiring Diagram................................................................8
Service Label ............................................................................9
Troubleshooting Guide ...........................................................10
SAFETY CONSIDERATIONS
Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified person-
nel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in the literature, tags, and
labels attached to or shipped with the unit and other safety
precautions that may apply.
Follow all safety codes. In the United States, follow all safety
codes including the National Fuel Gas Code NFPA No. 54-
1992/ANSI Z223.1-1992. In Canada, refer to the current edition of
the National Standard of Canada CAN/CGA-B149.1- and .2-M91
Natural Gas and Propane Gas Installation Codes. Wear safety
glasses and work gloves. Have fire extinguisher available during
start-up and adjustment procedures and service calls.
Recognize safety information. This is the safety-alert symbol
.
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage.
Fig. 3—Model 58TUA Upflow
A94085
Fig. 2—Model 58TMA
Downflow
A94086
Fig. 1—Model 58TMA Horizontal
A94087
®
ama
CANADIAN GAS ASSOCIATION
A P P R O VED
R
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 6a 8a
PC 101 Catalog No. 565-845 Printed in U.S.A. Form 58T-3SM Pg 1 1-95 Replaces: 58T-2SM
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - Induced-Combustion Furnace

58TMA, 58TUADeluxe 2-Speed Gas-FiredInduced-Combustion FurnaceService and Maintenance InstructionsFor Sizes 040-135, Series 100NOTE: Read the entire i

Page 2 - Information (In.)

A93386If inducer and burners continue to operate, check for 24v at the gas valve. If 24v are present, verify that the thermostat is open across R and

Page 3 - Fig. 6—Model 58TUA Upflow

The ability to properly perform maintenance on this equip-ment requires certain expertise, mechanical skills, tools, andequipment. If you do not posse

Page 4 - Fig. 7—Model 58TMA Downflow

1. Horizontal and Downflow.Each furnace requires 2 filters which are installed in thereturn-air duct. (See Fig. 4 and 5.) To remove filters forcleanin

Page 5

Lubricate motor every 5 years if motor is used on intermittentoperation (thermostat FAN switch in AUTO position), or every 2years if motor is in conti

Page 6 - Condensing Units

g. Flame-sensing electrode.h. Wiring connectors leading to control.6. Remove 8 screws that secure flue collector box to centerpanel. Be careful not to

Page 7

18. Check for gas leaks.19. Replace control door.Never use a match or other open flame to check for gas leaks.Use a soap-and-water solution. A failure

Page 8 - Fig. 12—Unit Wiring Diagram

replacement is required, use ONLY a 3-amp fuse. The control willdisplay code 24 when the fuse needs replacement.The control in this furnace is equippe

Page 9 - LED CODE STATUS

Fig. 12—Unit Wiring DiagramA94232FUSED DISCONNECTSWITCH (WHEN REQ'D)NOTE #1JBWHTBLKGRNGRNFU2COMPONENT TESTTo initiate the component test sequen

Page 10 - TROUBLESHOOTING

Fig. 13—Service LabelA94169SERVICEEACH OF THE FOLLOWING STATUS CODES IS A TWO-DIGIT NUMBER WITHTHE FIRST DIGIT DETERMINED BY THE NUMBER OF SHORT FLASH