PERFORMANCE AND ELECTRICAL DATA
MODEL 52SQ (265V)
MODEL
NUMBER
CAPACITY* (Btuh)
HEATER
kW
EER COP†
VOLT
RANGE
AMPS WATTS
Cooling
Heating
Cooling Heating** Cooling Heating
Rev. Cycle Electric
52SQD207---4 7,100 6,000 7,800 2.3 10.5 2.9
292-239
2.9 9.3 675 2435
52SQD307---4 7,100 6,000 11,600 3.4 10.5 2.9 2.9 13.4 675 3535
52SQD209---4 8,800 7,900 7,800 2.3 9.5 2.8 3.9 9.4 938 2435
52SQD309---4 8,800 7,900 11,600 3.4 9.5 2.8 3.9 13.5 938 3535
52SQC212---4 12,000 11,000 7,800 2.3 9.0 2.8 5.2 9.5 1333 2508
52SQC312---4 12,000 11,000 11,600 3.4 9.0 2.8 5.2 13.6 1333 3608
52SQC512---4 12,000 11,000 17,000 5.0 9.0 2.8 5.2 19.7 1333 5208
52SQC214---4 13,500 11,000 7,800 2.3 8.8 2.7 5.9 9.5 1535 2505
52SQC314---4 13,500 11,000 11,600 3.4 8.8 2.7 5.9 13.6 1535 3605
52SQC514---4 13,500 11,000 17,000 5.0 8.8 2.7 5.9 19.7 1535 5205
MODEL
NUMBER
POWER
FACTOR
%
FAN MOTOR
MAX. FUSE
SIZE
(Amps)
MIN.
CIRCUIT
AMPS
RECEP-
TACLE
TYPE††
R-22
CHARGE
(oz)
DEHUMIDI-
FICATION
(Pints/Hr)
APPROX.
CHASSIS
SHIP WT
(lb)
Horsepower
Full
Load
Amps
Indoor
CFM
HI/LO
52SQD207---4
97 1/15 0.56 280/200
15 11.6 A
26 3.00 125
52SQD307---4 20 16.8 B
52SQD209---4
98 1/8 0.7 350/300
15 11.6 A
26 2.33 128
52SQD309---4 20 16.8 B
52SQC212---4
98 1/6 0.8 380/310
15 11.8 A
34 3.40 12952SQC312---4 20 16.9 B
52SQC512---4 25 24.5 C
52SQC214---4
98 1/8 0.7 350/300
15 11.7 A
37 4.20 13052SQC314---4 20 16.8 B
52SQC514---4 25 24.5 C
LEGEND
EER — Energy Efficiency Ratio
*Rated in accordance with ARI Standard 310/380-93.
†Coefficient of Performance (COP) at 47 F outdoor ambient temperature.
**Electric resistance heater power and fan motor power.
††All 265V units require either the Accessory Hard-Wire Kit or the Accessory
Cord-Connected Kit for installation. Use of the Accessory Cord-Connected
Kit requires the installation of the Subbase along with a field-supplied recep-
tacle. Receptacle configurations of the Accessory Cord-Connected Kit are
shown at right.
RECEPTACLES AND FUSE TYPES
UNIT NAMEPLATE VOLTAGE 265
OUTLET RATED VOLTS/AMPS 277/15 277/20 277/30
OUTLET BLADE CONFIGURATION
A
B C
FEMALE RECEPTACLE MANUFACTURER’S
PART NO.
Arrow-Hart
Hubbell
Eagle
5302
—
834B-BOX
7621
—
384B-BOX
5795N
9315
—
NEMA CONFIGURATION 7-15R 7-20R 7-30R
TIME DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
15 20 30
HEATER (KILOWATTS) 2.3 3.4 5.0
LEGEND
HACR — Heating, Air Conditioning, and Refrigeration
NEMA — National Electrical Manufacturers Association