PROGRAMMABLE
DIGITAL THERMOSTAT
TST-EEPC06111SCS00 / TST-EEPD06111SCS01
TST-EEPC06121SCS00 / TST-EEPD06121SCS01
-7 Day Programmable
-CoolHeat and Ventilation
-Large, Easy To Read Display
-Blue Backlight
-Fahrenheit or Centigrade
Specification
Set-Point Range: 5-35(41-95)
Operating difference: ± 1
Switch current rating: < 2A
Sensing element : NTC
Display: LCD
Power supply:
TST-EEPC06111SCS00: AC85V~220V 50Hz/60Hz
TST-EEPD06111SCS01: AC85V~220V 50Hz/60Hz
TST-EEPC06121SCS00: AC24V ±10% 50Hz/60Hz
TST-EFPD06121SCS01: AC24V ±10% 50Hz/60Hz
Dimensions: 86 × 86 × 29.5 mm(W×H×D)
Housing: ABS Flame Retardant
Basic Operation
Power ON/OFF
To turn the thermostat on, press “ ”. Mode symbol ( , or ),
“RT”, and room temperature will be displayed.
To turn the thermostat off, press “ ” again. There is no any display on
LCD and no any output.
Select Mode:
Cool Setting:Press “M”, until the “ ” is displayed, it will be confirmed
automatically after 6 seconds.
Heat Setting:Press “M”, until the “ ” is displayed, it will be confirmed
automatically after 6 seconds.
Ventilation Setting:Press “M”, until the “ ” is displayed, it will be
confirmed automatically after 6 seconds.
Fan Setting:
Fan speed select: press the fan button to select “ Hi Med
Low Auto”. In mode“ Auto”, the fan-speed changed
automatically. Auto LOW-speed When the difference between
room-temperature and setting-temperature exceed 1(2), Auto
MED-speed When exceed 2(4), Auto HI-speed When exceed 3(6
).
Select Current Stage Temperature
TST-EEPC06111SCS00 / TST-EEPC06121SCS00:
Press”5” or ”6” until the desired temperature set point is displayed.
TST-EEPD06111SCS01 / TST-EEPD06121SCS01:
Press ”5” or ”6 until the desired heating or cooling temperature set
point is displayed.
Press the MODE button to select the second temperature setting(either
HEAT or COOL)
Set Current Time
Press the clock button. The hour of the time will flashing. Press the 5
and 6 buttons until the correct time is shown. Press the clock button
once,the minute of the time will flashing. Press the 5and 6buttons
until the correct time is shown. Press the clock button once,the day will
flashing. Press the “5” and “6” buttons to the day.
Error Codes
TST-EEPC06111SCS00 / TST-EEPC06121SCS00:
E1 — If the thermostat cannot properly read room temperature, and it
needs to be adjusted, E1 will be displayed.
TST-EEPD06111SCS01 / TST-EEPD06121SCS01:
E2 — If the thermostat cannot properly read outdoor temperature, and it
needs to be adjusted, E2 will be displayed.
Set Thermostat Configuration
Configuration options are intended to be selected at installation and
normally should not be modified by the home owner. These options are
not discussed in the Homeowner’s Guide and therefore must be made
as part of the installation. A special procedure allows entry in to the
configuration mode. The thermostat will automatically exit this if no
button is pressed for 90seconds.
An explanation for each of these and how to enter the configuration
mode follows.
To enter the configuration mode:
To enter the configuration mode, hold the fan button down for
approximately 15 seconds. After 15 the second periof,Option”01” will
appear in the display.
OPTION 01 –LOW TEMPERATURE PROTECTION (FROST
PROTECTION)
In the low temperature protection mode, When the thermostat is off , and
the room temperature is lower than 5, it will be turned on automatically
and in heating mode; When the room temperature is higher than 7, it
will be turned off automatically.
TO ADJUST:
Enter configuration mode (if not already there).
Use 5and 6buttons to display Option 01.The SET icon should be
off.
Press” M ” button once. The SET icon will be come on. The display now
shows Option 01 setting.
Use 5 and 6 buttons to move between the available Option 01
choices of 00(disable) or 01(enable). Factory default is 00.
Press” M ” button again to return to Option 01. The SET icon will now be
off.
Use “5” and “6” buttons to select another Option, or press” “button
to exit configuration mode.
OPTION 02 –FAHRENHEIT/CELSIUS SELECTION
This option selects Fahrenheit or Celsius operation.
TO ADJUST:
Enter configuration mode (if not already there).
Use 5and 6buttons to display Option 02.The SET icon should be
off.
Press” M ”button once. The SET icon will be come on. The display now
shows Option 02 setting.
Use 5 and 6 buttons to move between the available Option 02
choices of F (Fahrenheit) or C (Celsius). Factory default is C.
Press” M ”button again to return to Option 02. The SET icon will now be
off.
Use “5” and 6” buttons to select another Option, or press “button
to exit configuration mode.
OPTION 3ROOM TEMPERATURE OFFSET
This option allows calibration (or deliberate miscalibration) of room
temperature sensor. There are various reasons why the home owners
want to adjust the displayed temperature. The selected number is the
number of degrees, plus or minus, which will be added to the actual
temperature. The number can range between -5 and +5. Factory default
is 0. This adjusted value will be used as actual temperature for both
display and control action.For example, if 2 is selected, 72F actual will
read 74F. If setpoint is 72, the room will control to an actual value of 70
which will be displayed and acted upon as if it were 72. The effect is that
a positive number selection will make the room temperature lower and
vice versa. This thermostat is factory calibrated within an accuracy of
plus or minus 1F, so this adjustment will provide the best accuracy when
set to 0.
TO ADJUST:
Enter configuration mode(if not already there).
Use 5and 6buttons to display Option 03.The SET icon should be
off.
Press” M ”button once. The SET icon will be come on. The display now
shows Option 03 setting.
Use 5 and 6 buttons to move between the available Option 01
choices of -5 through +5 in 1 step. Factory default is 0.
Press” M ”button again to return to Option 03. The SET icon will now be
off.
Use “5” and 6” buttons to select another Option, or press “button
to exit configuration mode.
OPTION 04 –SAVE CONFIGURATION DATA
This option can be used to choose Save configuration data
TO ADJUST
Enter configuration mode (if required).
Use up and down buttons to display Option 04.The SET icon should be
off.
Press” M ” button once. The SET icon will come on. The display now
shows Option 04 setting.
Use 5 and 6 buttons to move between the available Option 04
choices of 00(disable) or 01(enable). Factory default is 01.
Press ” M” button again to return to Option 04. The SET icon will now be
off.
Use “5” and 6” buttons to select another Option, or press
“button
to exit configuration mode.
Programming Thermostat Schedules
Before programming the thermostat, plan the thermostat daily schedule. The
schedule is divided into 7 days (Monday through Sunday). Each day has 4
time periods (1,2, 3, 4). Each time period has a start time, heating
set point, and cooling set pointFill in Table 1 as an aid to programming
the daily schedules.
NOTE: TST-EEPC06111SCS00 / TST-EEPC06121SCS00has single
temperature set point.
To program the daily schedules,perform the following procedure:
1. Enter programming mode by hold the clock button down for 5 seconds.
“Wen” and ”--:--” will be displayed. Use 5” and 6” buttons to select the day
of the schedule. Press The clock button TIME annunciator will flash.
NOTE: If a programming button is not pushed for 90 seconds, the
thermostat will exit programming mode.
2. Press the 5and 6buttons to set the start time for the schedule day
and period shown.
3. Press the clock button once, The heating set point and the
heat
annunciator will be displayed. Press the 5” and 6buttons to set heating
set point.
4. Press the clock button once, The cooling set point and the cool
annunciator will be displayed. Press the 5and 6 buttons to set cooling
set point.
5. Press the clock button to advance to the next time period.
6.
Perform Steps 2 through 5 until the times and temperature set points have
been entered for the entire day. Press the clock button and display”copy”,use
5 and 6 buttons to select the day for copy, press the clock button to
confirm.
7.
Repeat Steps 2 through 6 to program the remaining schedule days.
SCHEDULE
1 2 3 4
DAY OF
WEEK
Tim/Heat/Cool Tim/Heat/Cool Tim/Heat/Cool Tim/Heat/Cool
Monday / / / / / / / / / / / /
Tuesday / / / / / / / / / / / /
Wednesday / / / / / / / / / / / /
Thursday / / / / / / / / / / / /
Friday / / / / / / / / / / / /
Saturday / / / / / / / / / / / /
Sunday / / / / / / / / / / / /
TST-EEPC06111SCS00/ TST-EEPC06121SCS00:
TST-EEPD06111SCS01/ TST-EEPD06121SCS01:
Table 1 Daily Schedule Planner
Power button
Mode button Fan button Down button Up button
Shows room temperature,
desired temperature, and
other feature information
as required.
Room temperature
Set
desired temperature
Change mode
Cool mode
Heat mode
Fan indicator
SET
Clock button
Current Time
Ventilation mode
Wire Diagram
L(R)
Val
Low
Med
Hi
N(C)
L(R)
Val
Low
Med
Hi
N(C)
Thermostat
Fan coil
L(R)
Val
Low
Med
Hi
N(C)
S1
S2
OUTDOOR SENSOR
CONNECTION
L(R)
Val
Low
Med
Hi
N(C)