Installation Instructions
Part Numbers 33CS2PPRH-01 and 33CS2PP2S-01
CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
PACKAGE CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION CONSIDERATIONS . . . . . . . . . . . . . .1,2
Control Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Outdoor Temperature Sensor . . . . . . . . . . . . . . . . . . . . 2
Remote Indoor Temperature Sensor. . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Thermostat Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Wiring Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Two-Piece Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Single-Piece Installation . . . . . . . . . . . . . . . . . . . . . . . . . 5
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Humidification Equipment and Connections
(33CS2PPRH-01 Model Only). . . . . . . . . . . . . . . . . . . . 5
Dehumidification Equipment and Connections. . . 5
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
To Enter and Exit Configuration Mode. . . . . . . . . . . . 5
Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SYSTEM START-UP AND CHECKOUT . . . . . . . . . .9,10
Installer Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Final Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Default Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting the Clock, Calendar, Daily Schedule,
and Holiday Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Humidity Control Features
(33CS2PPRH-01 Only). . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Holiday. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10,11
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Heat/Cool Set Points (Desired Temperature). . . . . 11
Equipment On Indicators. . . . . . . . . . . . . . . . . . . . . . . . 11
Humidification and Dehumidification
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Auto Changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Emergency Heat Mode . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dry Contact/Economizer Input . . . . . . . . . . . . . . . . . . 11
TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . 11-19
THERMOSTAT CONFIGURATION RECORD . . . . CL-1
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Fol-
low all local electrical codes during installation. All wiring
must conform to local and national electrical codes. Improper
wiring or installation may damage sensor.
Recognize safety information. This is the safety alert sym-
bol . When the safety alert symbol is present on equipment
or in the instruction manual, be alert to the potential for person-
al injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.
GENERAL
Carriers 7-day, 5/2-day, or 1-day programmable commer-
cial thermostat control is a wall-mounted, low-voltage control
which provides temperature control in either a single unit or a
two-piece unit. The 33CS2PPRH-01 will provide both temper-
ature and humidity control. In two-piece configuration, the re-
lays are located near the equipment and a two-wire connection
is used between the display module (user interface) and the
equipment control module. Single-piece installation requires
more wiring and results in a higher profile. The thermostat has
no need for batteries to store user-configured settings in memo-
ry. During power loss its internal memory saves settings for un-
limited time, and the clock continues to run for at least
24 hours.
In the programmable configuration, different heating and
cooling set points and times are programmable for 4 periods
per day or 2 periods per day. Programming can be done for
7 days per week, 5 and 2 days per week, or 1 day. The pro-
grammable control can also be user configured as a non-
programmable control.
PACKAGE CONTENTS
1 — Display module
1 — Stand-off for equipment control module
2 — Screws and anchors
1 — Pigtail
1 — Equipment control module with cover
INSTALLATION CONSIDERATIONS
There are two types of thermostats available. The
33CS2PP2S-01 provides temperature control and the
33CS2PPRH-01 provides both temperature and humidity con-
trol. Both models can be configured for air conditioner or heat
pump installations and may be configured as non-programma-
ble if user desires.
Control Configuration — The thermostat can be in-
stalled in one of two configurations. The thermostat may be in-
stalled as a single-piece or it may be split into two pieces and
mounted in separate locations.
IMPORTANT: Read entire instruction before installing
the thermostat.
EDGE
®
Pro
Programmable
Commercial Thermostat
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Installation Instructions

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Cata

Page 2

10Fig. 12 for outdoor temperature/indoor humidity relationship inauto humidification mode.Humidification Off — The humidification function can beturne

Page 3

11defeated for one cycle by simultaneously pressing the OCCU-PIED and UP buttons.TEN-MINUTE STAGING TIMER — In multistage heatingor cooling, this ti

Page 4 - CONTACT

12Fig. 13 — Thermostat Wiring — 48/50HE003-006, 48/50HJ004-028, 48/50TF004-014, 48/50TJ016-028,48/50TM004-028, 50HEQ003-006, and 50HJQ,TFQ004-012 Roof

Page 5

13Fig. 15 — Thermostat Wiring — 48/50HG,PG,PM Rooftop UnitsFig. 16 — Thermostat Wiring — 48/50TC Rooftop UnitsRcRhW1GY2CO/W2/BY1OATRRSSRTNHUMD1D2V+VgR

Page 6 - Configuration Options

14Fig. 17 — Thermostat Wiring — 50HJQ014,016 Heat Pump UnitsFig. 18 — Thermostat Wiring — 50EJQ,EWQ024,028 Heat Pump UnitsRcRhW1GY2CO/W2/BY1OATRRSSRTN

Page 7

15Fig. 19 — Thermostat Wiring — 38ARD Commercial Split System UnitsFig. 20 — Thermostat Wiring — 38 Series and 40 Series Split System UnitsRcRhW1GY2CO

Page 8

16Fig. 21 — Thermostat Wiring — 50HQL, KQE, KQL, PC, PEC, PS, PSW, PT, RHC, RHE, RHR, RHS, RTG, RVC, RVE, RVR, RVS, RWS, VQL Water Source Heat Pump U

Page 9

17Fig. 23 — Thermostat Wiring — 50PS, PT, RHS, RVS, VQL Water Source Heat Pump Units with Deluxe DControls and Factory-Installed Reheat OptionFig. 24

Page 10 - OPERATION

18Fig. 25 — Thermostat Wiring — Space Temperature Sensor Averaging WiringCOMMERCIALTHERMOSTATSENSOR 4SENSOR 1SENSOR 1SENSOR 1SENSOR 8SENSOR 7SENSOR 5

Page 11

19Fig. 26 — Thermostat Wiring — Humidifier and DehumidifierFig. 27 — Thermostat Wiring — Humidifier and Blower FanRcRhW1GY2CO/W2/BY1OATRRSSRTNHUMD1D

Page 12 - Humidi-MiZer™ FIOP

2As a single-piece unit, all required wiring must be broughtto the equipment control module for connection to the terminalstrip. In two-piece configur

Page 13 - COMMAND CENTER

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Cata

Page 17 - TERMINAL BOARD

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Cata

Page 18 - COMMERCIAL

3Fig. 3 — Mounting Plate Installation6. Secure rear plastic mounting base to wall with 2 screwsand anchors provided. Additional mounting holes areavai

Page 19 - HUMIDIFIER

4Fig. 7 — Equipment Control Module MountingFig. 8 — Standoff Installed on Equipment Control Module16. Match and connect equipment wires to proper term

Page 20

5Single-Piece Installation — For single-piece installa-tion, perform the following procedure.1. Turn off all power to equipment.2. If an existing ther

Page 21

6event of the 3-minute timeout or when installer exits from con-figuration menu. See Table 1.Table 1 — Configuration Options LEGEND*

Page 22

7non-programmable. Allowable selections are OF (off), 30, 60,and 90. The default is 90.OPTION 13 — SPACE TEMPERATURE OFFSETADJUSTMENT — This configura

Page 23

8The default is OF (off).OPTION 24 — PROGRAMMABLE/NON-PROGRAM-MABLE — This selection allows the installer to configurethe thermostat as either progra