HORIZONTAL LEFT -
RIGHT VENT CONFIGURATION*
*Requires Accessory Internal Vent Kit
See Product Data for Current Kit Number
HORIZONTAL LEFT -
VERTICAL VENT CONFIGURATION
HORIZONTAL LEFT -
LEFT VENT CONFIGURATION
Attach vent pipe adapter with gasket to furnace casing.
Align notches in rubber coupling over standoffs on adapter. Slide clamps over the coupling.
Slide vent pipe through adapter and coupling into vent elbow.
Insert vent pipe into vent elbow.
Torque all clamps 15 lb.-in.
Attach combustion air pipe to adapter with silicone. Pilot drill a 1/8-in.
hole in adapter and secure with a #7 x 1/2-in sheet metal screw.
1
2
3
4
5
6
7
Attach combustion air pipe adapter with gasket to furnace.
A11340
Fig. 40 -- Horizontal Left
(Appearance May Vary)