SPECIFICATIONS
Heating Capacity and Efficiency 060-14 080-14 100-20 120-22
Input
Maximum Heat (BTUH) 60,000 80,000 100,000 120,000
Intermediate Heat (BTUH) 39,000 52,000 65,000 78,000
Minimum Heat (BTUH) 24,000 32,000 40,000 48,000
Output
Maximum Heat (BTUH) 59,000 78,000 97,000 117,000
Intermediate Heat (BTUH) 38,000 51,000 63,000 76,000
Minimum Heat (BTUH) 24,000 31,000 39,000 47,000
Efficiency AFUE % (ICS) 97.4 97.4 97.1 97.2
Certified Temperature
Rise Range ºF (ºC)
Maximum Heat
35 - 65
(19-36)
40 - 70
(21-38)
45 - 75
(25-41)
45 - 75
(25-41)
Intermediate Heat
50 - 80
(27-44)
50 - 80
(27-44)
50 - 80
(27-44)
50 - 80
(27-44)
Minimum Heat
35 -65
(19-36)
35 - 65
(19-36)
35 - 65
(19-36)
35 - 65
(19-36)
Airflow Capacity and Blower Data 060-14 080-14 100-20 120-22
Certified External Static
Pressure (in. w.c.)
Heating 0.12 0.15 0.20 0.20
Cooling 0.5 0.5 0.5 0.5
Airflow Delivery
@RatedESP(CFM)
Maximum Heat 1075 1510 1515 1815
Intermediate Heat 530 750 905 1100
Minimum Heat 415 620 725 900
Cooling 1335 1375 2030 2185
Cooling Capacity (tons)
@ 400, 350 CFM/ton
400 CFM/ton 3 3.5 5 5.5
350 CFM/ton 3.5 4 5.5 6
Direct-Drive Motor Typ e Electronically Commutated Motor (ECM)
Direct-Drive Motor HP 1/2 1/2 1 1
Motor Full Load Amps 7.7 7.7 12.8 12.8
RPM Range 300 - 1300
Speed Selections Variable (Communicating)
Blower Wheel Dia. X Width in. 11 x 8 11 x 8 11 x 10 11 x 11
Air Filtration System
Factory Supplied Media Cabinet
FieldSuppliedFilter
Filter Used for Certified Watt Data KGAWF1306UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR
Electrical Data 060-14 080-14 100-20 120-22
Input V oltage Volts-Hertz-Phase 115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Input Amps Amps 9.7 9.7 14.8 14.8
Unit Ampacity Amps 12.7 12.7 19.1 19.1
Minimum Wire Size AWG 14 14 12 12
Maximum Wire Length
@ Minimum Wire Size
Feet 29 29 30 30
(M) (8.8) (8.8) (9.1) (9.1)
Maximum F use/Ckt Bkr
(Time-Delay Type Recommended)
Amps 15 15 20 20
Transformer Capacity (24vac output) 40 VA
External C ontrol Power
Available
Heating 27.9 VA
Cooling 27.9 VA
Controls 060-14 080-14 100-20 120-22
Gas Connection Size 1/2” - NPT
Burners (Monoport) 3 4 5 6
Gas Valve (Redundant)
Manufacturer White Rogers
Minimum Inlet Gas
pressure (in. W.C.)
4.5
Maximum Inlet Gas
pressure (in. W.C.)
13.6
Gas Conversion Kit - Natural to Propane KGANP5201VSP
Gas Conversion Kit - Propane to Natural KGAPN4401VSP
Manufactured (Mobile) Home Kit not approved for MH use
Ignition Device Silicon Nitride
Limit Control 180 170 160 160
Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay) 90 seco nds
Communication System Infinity; Infinity Zoning
Thermostat Connections W2,Y1,DHUM,G,COM24V,W/W1,Y/Y2,R
Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)