Copyright 2003 Carrier Corporation Form 48/50HG-3PD
Ultra High Performance, Single
Package Rooftop Units with:
Cooling EERs up to 11.6
IPLV’s up to 13.7
Easy fit up to previously installed
Carrier DP, DR, HJ, or TJ roof curbs
Dedicated vertical or side-by-side
horizontal airflow units
Communicating
Comfort
Link con-
trols with Scrolling Marquee display
Slide-out indoor fan system
assembly
Service access panels with double
wall construction, stainless steel
hinges, tiebacks, and quick turn
latches
Low outdoor sound levels of
8.2 bels (8.5 bels on 028)
Scroll compressors with crankcase
heaters
Three mechanically and electroni-
cally independent refrigerant circuits
on 016, 020, and 024 units and two
mechanically and electronically
independent refrigerant circuits on
014 and 028 units
TXV refrigerant metering devices
Cabinet made of pre-painted galva-
nized steel with baked enamel finish
and fully insulated
0° to 125 F ambient cooling opera-
tion capability standard
Standard one-year parts warranty,
5-year compressor warranty,
10-year gas heat exchanger war-
ranty and 5-year factory-installed
electric heater warranty with many
options
Internally sloped condensate pan
ensures proper drainage and helps
eliminate any condensate build-up
in the pan
48HG014-028
50HG014-028
Single Package
Rooftop Units
with ComfortLink™ Control
13 to 25 Nominal Tons
Product
Data
48/50HG014-028
CENTURION UNIT
Page view 0
1 2 ... 80

Summary of Contents

Page 1 - Rooftop Units

Copyright 2003 Carrier Corporation Form 48/50HG-3PDUltra High Performance, Single Package Rooftop Units with:• Cooling EERs up to 11.6• IPLV’s up to 1

Page 2 - Features/Benefits

10LEGENDUNIT 50HG 014 016 020VOLTAGE208/230and 460575208/230and 460575208/230and 460575NOMINAL CAPACITY (Tons)13 13 15 15 17.5 17.5OPERATING WEIGHT (l

Page 3

11LEGENDUNIT 50HG 024 028VOLTAGE208/230and 460575 ALLNOMINAL CAPACITY (Tons)20 20 25OPERATING WEIGHT (lb)50 SERIES (Cooling Only)2187 2187 2446COMPRES

Page 4 - Features/Benefits (cont)

12*Factory-installed. †Field-installed.NOTE: Refer to 48/50HG price pages or contact your local representative for accessoryand option package informa

Page 5 - ARI* capacity ratings

13Base unit dimensions — 48HG014-028

Page 6 - ARI capacity ratings (cont)

14Base unit dimensions — 50HG014-028

Page 7 - OUTDOOR SOUND POWER

15Accessory dimensionsROOF CURB — FULL PERIMETER CURB

Page 8

16Accessory dimensions (cont)1’-7 7/8” (505)1’-0 7/16”(316)1’-4 5/16”(415)6 1/8” (155)2 1/8” (53)1’-3” (381)7/8-IN. K.O.3-IN. K.O.EXISTING APPLICATION

Page 9

17I Determine cooling and heating requirementsat design conditions.Given:Required Gross CoolingCapacity (TC) . . . . . . . . . . . . . . .229,000 Btu

Page 10

18I Determine cooling and heating requirementsat design conditions.Given:Required Gross CoolingCapacity (TC) . . . . . . . . . . . . . . .168,000 Btu

Page 11

19COOLING CAPACITIESSee Legend and Notes on page 21.48/50HG014 (13 Tons)TemperatureAir EnteringCondenser(Edb) (F)Evaporator Air Quantity — Cfm/BF3750/

Page 12 - Options and accessories

2Every compact one-piece unit arrives fully assembled, charged, tested, and ready to run.Cooling EERsThe 48/50HG014 (13 tons) units pro-vide ARI (Air

Page 13

20COOLING CAPACITIES (cont)48/50HG020 (171/2 Tons)TemperatureAir EnteringCondenser(Edb) (F)Evaporator Air Quantity — Cfm/BF5400/0.03 6300/0.04 7200/0.

Page 14

21COOLING CAPACITIES (cont) LEGEND AND NOTES FOR COOLING CAPACITY TABLESLEGENDNOTES:1. Direct interpolation is permissible. Do not extrapolate.2. The

Page 15 - Accessory dimensions

22FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return)LEGEND*For standard motor with standard drive, the drive range is 485 to613 rpm (208/23

Page 16 - Accessory dimensions (cont)

23FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 485 to613 rpm

Page 17

24FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 618 to789 rpm

Page 18

25FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 618 to789 rpm

Page 19 - Performance data

26FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rpm.

Page 20 - Performance data (cont)

27FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rpm.

Page 21 - COOLING CAPACITIES (cont)

28FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rpm.

Page 22

29FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rpm.

Page 23

3Durable, dependable constructionDesigned for durability in any climate, the weather-resistant cabinets are con-structed of galvanized ste

Page 24

30FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 799 to965 rpm.

Page 25

31FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 799 to965 rpm.

Page 26

32FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 485 to613 rpm

Page 27

33FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 618 to789 rpm

Page 28

34FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rpm.

Page 29

35FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rpm.

Page 30

36FAN PERFORMANCE — 48/50HG014-028 (Vertical Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 799 to965 rpm.

Page 31

37FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return)LEGEND*For standard motor with standard drive, the drive range is 485 to613 rpm (208/

Page 32

38FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 485 to613 rp

Page 33

39FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 618 to789 rp

Page 34

4switch also deenergizes the gas valve in the event of a flame rollout.ComfortLink™ controlThe ComfortLink control is your link to a world of simple a

Page 35

40FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 618 to789 rp

Page 36

41FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rp

Page 37

42FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rp

Page 38

43FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rp

Page 39

44FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rp

Page 40

45FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 799 to965 rp

Page 41

46FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 799 to965 rp

Page 42

47FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 485 to613 rp

Page 43

48FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 618 to789 rp

Page 44

49FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rp

Page 45

5LEGEND*Air Conditioning and Refrigeration Institute.†IPLV values are calculated based on control configuration T.CTL = 2(2 Stage Y1).**Size 028 unit

Page 46

50FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 658 to808 rp

Page 47

51FAN PERFORMANCE — 48/50HG014-028 (Horizontal Supply and Return) (cont)LEGEND*For standard motor with standard drive, the drive range is 799 to965 rp

Page 48

52POWER EXHAUST FAN PERFORMANCE — 48/50HG014-028LEGENDESP — External Static PressureALTITUDE COMPENSATION* — 48HG014-028(Natural Gas)*As the height ab

Page 49

53ACCESSORY/FIOP ELECTRIC HEAT STATIC PRESSURE (in. wg) — 50HG014-028 UNITS LEGENDNOTES:1. Heaters are rated at 240 v, 480 v, and 600 v

Page 50

54FAN RPM AT MOTOR PULLEY SETTINGS**Approximate Rpm shown.EVAPORATOR FAN MOTOR SPECIFICATIONSLEGENDBkW — Brake kilowatts48/50HG MOTOR AND DRIVETURNS O

Page 51

5548HG014-028 WITHOUT OPTIONAL CONVENIENCE OUTLETSee Legend and Notes on page 57.UNITSIZE48HGNOMINAL VOLTAG E (3 Ph, 60 Hz)VOLTAGERANGECOMPRESSOROFM I

Page 52

5648HG014-028 WITH OPTIONAL CONVENIENCE OUTLETSee Legend and Notes on page 57.UNITSIZE48HGNOMINAL VOLTAGE (3 Ph, 60 Hz)VO LTAG ERANGECOMPRESSOROFM IFM

Page 53

5750HG014-028 WITHOUT OPTIONAL CONVENIENCE OUTLETLEGEND AND NOTES FOR ELECTRICAL DATA TABLESLEGEND*Fuse or HACR circuit breaker.†208/230 v 75-kW Elect

Page 54

5850HG014-028 UNITS WITHOUT OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 U

Page 55 - Electrical data

5950HG014-028 UNITS WITHOUT OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 U

Page 56 - Electrical data (cont)

6VERTICAL SUPPLY UNITS WITH FIELD-INSTALLED LIQUID PROPANE KIT*All units are 2-stage heat.†Minimum heating cfm must be maintained to ensure proper hea

Page 57

6050HG014-028 UNITS WITHOUT OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 U

Page 58

6150HG014-028 UNITS WITHOUT OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 U

Page 59

6250HG014-028 UNITS WITH OPTIONAL CONVENIENCE OUTLETSee Legend and Notes on page 57.UNITSIZE50HGNOMINAL VOLTAGE (3 Ph, 60 Hz)VO LTAG ERANGECOMPRESSORO

Page 60

6350HG014-028 UNITS WITH OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 UNIT

Page 61

6450HG014-028 UNITS WITH OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 UNIT

Page 62

6550HG014-028 UNITS WITH OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 UNIT

Page 63

6650HG014-028 UNITS WITH OPTIONAL CONVENIENCE OUTLET (cont)ELECTRIC HEAT BRANCH CIRCUIT FOR 208/240 75-kW ELECTRIC HEATFEEDER CIRCUIT FOR 208/230 UNIT

Page 64

67Typical wiring schematicLOW VOLTAGE CONTROL SCHEMATIC — 48HG

Page 65

68Typical wiring schematic (cont)LOW VOLTAGE CONTROL SCHEMATIC — 50HG

Page 66

69POWER SCHEMATIC — 48/50HG

Page 67 - Typical wiring schematic

7OPERATION AIR QUANTITY LIMITS*7000 cfm recommended for operation above 1.0 in. wg external static pressure.MULTIPLICATION FACTORSNOTE: The following

Page 68

70Typical wiring schematic (cont)FIOPSSMOKE DETECTOR WIRING

Page 69 - POWER SCHEMATIC — 48/50HG

71Typical component arrangement---.A —Circuit AAUX —Auxiliary Contact---.B —Circuit B---.C —Circuit CC —Compressor, ContactorCAP —CapacitorCB —Circuit

Page 70 - SMOKE DETECTOR WIRING

72Operating sequenceHeating48HG UnitsNOTE: The 48HG units have 2 stages of gas heat.When the thermostat calls for heating, power is sent to Won the IG

Page 71 - Typical component arrangement

73If the indoor fan is not operating, the economizer will beclosed.The 48/50HG units can also be equipped with optionalCO2 sensors for additional indo

Page 72 - Controls

74DuctworkDuctwork should be attached to the curb on all units. Inte-rior installation may proceed before unit is set in place onroof. If ductwork wil

Page 73

75Indoor air qualityAn indoor air quality sensor, which senses CO2, is afactory-installed option. The sensor in conjunction with theeconomizer is used

Page 74 - Application data

76Packaged Rooftop Electric CoolingUnit with Gas or Electric Heat —Constant Volume ApplicationHVAC Guide SpecificationsSize Range:13 to 25 Tons, Nomin

Page 75 - Fan status

773. Induced-draft blower shall be of the direct-driven, single inlet, forward-curved, centrifugaltype. It shall be made from steel with acorrosion-re

Page 76 - Constant Volume Application

78c. Unit control with standard suction pressuretransducers and condensing temperaturethermistors.d. Shall provide a 5 F temperature differencebetween

Page 77

79* 3. Barometric Relief Damper Package:a. Package shall include damper, seals, hard-ware, and hoods to relieve excess internalpressure.b. Damper shal

Page 78

8LEGENDUNIT 48HG 014 016 020VOLTAG E208/230 and 460575208/230 and 460575208/230 and 460575NOMINAL CAPACITY (Tons)13 13 15 15 17.5 17.5OPERATING WEIGHT

Page 79

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.New

Page 80

9LEGENDUNIT 48HG 024 028VOLTAG E208/230 and 460575 ALLNOMINAL CAPACITY (Tons)20 20 25OPERATING WEIGHT (lb)48 SERIES (Low Heat)2272 2272 2526COMPRESSOR

Comments to this Manuals

No comments