50SZ
SINGLE-PACKAGED
HEAT PUMP UNITS
2 to 5 Nominal Tons
Product Data
Single-Packaged Heat Pump for
Residential and Light Commercial
Applications
• Low Sound Levels
• 13 SEER
Features/Benefits
One-piece heat pump with optional
electric heater, low installation cost,
dependable performance and easy
maintenance.
Efficient operation
High-efficiency design
with SEERs
(Seasonal Energy Efficiency Ratios)
of 13.0 and HSPFs (Heating Seasonal
Performance Factors) of up to 7.7.
Easy Installation
Factory-assembled package
is a
compact, fully self-contained, heat
pump unit that is pre-wired, pre-piped,
and pre-charged for minimum
installation expense. 50SZ units are
available in a variety of standard
capacity ranges with voltage options to
meet residential and light commercial
requirements. Units install easily on a
rooftop or at ground-level.
Durable, dependable
components
Scroll Compressors
are designed for
high efficiency. Each compressor is
hermetically sealed against
contamination to help promote longer
life and dependable operation.
Vibration isolation provides quiet
operation. Compressors have internal
high-pressure and overcurrent
protection.
Direct-drive multi-speed, PSC
(permanent split capacitor) blower
motor
is standard on all 50SZ models.
Direct-drive, PSC condenser-fan
motors
are designed to help reduce
energy consumption and provide for
cooling operation down to 40°F outdoor
temperature. Motormaster® II low
UNIT 50SZ
(STANDARD)
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Product Data

50SZSINGLE-PACKAGEDHEAT PUMP UNITS2 to 5 Nominal TonsProduct Data Single-Packaged Heat Pump for Residential and Light Commercial Applications• Low Sou

Page 2 - Table of contents

1050SZ50SZ Corner weights ( In Pounds)I Determine cooling and heating requirements at design conditions:Given:Required Cooling Capacity (TC) . . . .

Page 3 - ARI* capacities

1150SZPerformance dataCOOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60See Legend an

Page 4 - Physical data

1250SZPerformance data (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60See Le

Page 5 - Options and accessories

1350SZPerformance data (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60See Le

Page 6 - ECONOMIZER

1450SZPerformance data (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60See Le

Page 7 - NEC. REQUIRED CLEARANCES

1550SZPerformance data (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60See Le

Page 8

1650SZPerformance data (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60See Le

Page 10

1850SZPerformance data (cont)ECONOMIZER 1-in. FILTER PRESSURE DROP (in. wg)MULTIPLICATION FACTORSExample: 20 kW (at 240v) heater on 230v= 20.0 (.92 mu

Page 11 - Performance data

1950SZWET COIL AIR DELIVERY UNIT 50SZ024-060**Air delivery values are based on operating voltage of 230 v, wet coil, without filter or electric heater

Page 12 - Performance data (cont)

250SZ ambient kit is available as a field-installed accessory and does not require a special motor. Corporate thermostats work with Carrier’s small p

Page 13

2050SZINDOORTHERMOSTATDISCONNECTPER NECFROMPOWERSOURCERETURNAIRTOP COVERTypical piping and wiring

Page 14

2150SZCondensate trap — A 2-in. condensate trap must be fieldsupplied.Ductwork — Secure downflow discharge ductwork to roofcurb. For horizontal discharg

Page 15

2250SZElectrical Data*Heater capacity (kW) based on heater voltage of 208v, 240v, & 480v. If power distribution voltage to unit varies from rated

Page 16

2350SZElectrical Data Legend452=5v457=7v455=2vLEGENDFLA — Full Load AmpsLRA — Locked Rotor AmpsMCA — Minimum Circuit AmpsMOCP — Maximum Overcurrent Pr

Page 17

2450SZ

Page 18

2550SZSequence of operationWhen power is supplied to unit, the transformer (TRAN) isenergized.On units with crankcase heater, heater is also energized

Page 19 - FILTER PRESSURE DROP (In. wg)

2650SZPackaged Heat PumpsConstant Volume ApplicationHVAC Guide SpecificationsSize Range: 2 to 5 Tons, Nominal CoolingCarrier Model Number: 50SZPart 1—

Page 20 - Typical piping and wiring

2750SZ2. All fan motors shall have permanently lubricatedbearings, and inherent, automatic reset, thermaloverload protection.3. Condenser fan motor sh

Page 21 - Application data

Copyright 2005 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06Manufacturer reserves the right to cha

Page 22 - Electrical Data

350SZ Model number nomenclatureARI* capacities COOLING CAPACITIES AND EFFICIENCIES 50SZ 024Model No. 50SZ – Single Packaged Heat Pump Nomi

Page 23 - Electrical Data Legend

450SZ OUTDOOR SOUND: OCTAVE BAND DATA—DECIBELS Physical data * Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg. UNIT 50S

Page 24

550SZ Factory-installed optionsLouvered grille provides hail and vandalism protection. A wire grille is standard on all models. See model number nom

Page 25 - Controls

650SZECONOMIZERFILTER RACK MANUAL OUTSIDE AIR DAMPERDAMPERBLADEMANUAL OUTSIDEAIR HOODREPLACEMENTPANEL

Page 26 - Guide specifications

750SZBase unit dimensions—50SZ024-030REQUIRED CLEARANCE FOR OPERATION AND SERVICINGINCHES [mm]EVAP. COIL ACCESS SIDE...

Page 27 - Guide specifications (cont)

850SZBase unit dimensions—50SZ036-060REQUIRED CLEARANCE FOR OPERATION AND SERVICINGINCHES [mEVAP. COIL ACCESS SIDE...

Page 28

950SZAccessory dimensionsNOTES:1. Roof curb must be set up for unit being installed.2. Seal strip must be applied, as required, to unit being installe