Date: Supersedes:
48TM16-028
SINGLE-PACKAGE COOLING UNIT
WITH FACTORY-INSTALLED GAS HEAT
48TM Rev.:
JOB NAME: LOCATION:
BUYER: BUYER P.O. # CARRIER #
UNIT NUMBER: MODEL NUMBER:
UNIT DESIGNATION:
PERFORMANCE DATA CERTIFIED BY: DATE:
ARI STANDARD
360
DESCRIPTION
48TM units are one-piece rooftop cooling units with gas heat. All units are pre-wired and
pre-charged with R-22 at the factory. Units are factory tested in both heating and cooling modes.
The 48TM units have bottom air openings for separate supply and return ductwork. The 48TMD
model is low heat and the 48TMF model is high heat. The 48TMM model is low heat with
stainless steel heat exchangers and the 48TMN model is high heat with stainless steel heat
exchangers. The 48TM unit is intended for installation on an accessory curb (ordered separately).
Horizontal supply and return connections are also possible with a factory-preassembled,
high-static regain, horizontal conversion adapter roof curb accessory (ordered separately).
Bottom discharge on concentric applications requires a transition duct (field-supplied) external to
the unit.
FEATURES
All units meet ASHRAE Standard 90.1.
Standard one-year product warranty.
Five-year non-prorated warranty on Alumagard™ coated Turbo-
tubular™ gas heat exchanger.
Five-year warranty on the compressor (48TM016). One year warranty
on the compressor (48TM020-028).
Units are rated in accordance with ARI standard 360. Standard unit is
certified and listed by ETL and ETL, Canada.
Low outdoor temperature cooling operation to 40 F (4 C) as standard.
Dual freezestat protection is provided as standard.
Dual scroll compressors with internal linebreak protection.
Indoor and outdoor coils constructed of aluminum fins mechanically
bonded to seamless internally grooved copper tubes.
Dual TXVs (thermostatic expansion valves) metering devices.
Liquid line filter driers provided in each refrigeration circuit.
Optional gear-driven EconoMi$er equipped with microprocessor
controller that includes CO
2
ventilation control capability.
Manually adjustable outside air intake for up to 25% outside air.
Automatic changeover (when used with an auto-changeover
thermostat).
Single point gas and electric connections. Disconnect in accordance
with NEC must be field-supplied and installed.
All units utilize 2-stage cooling.
Belt drive adjustable evaporator fan.
Choice of low-medium or high-static indoor fan drive capability.
Cabinet made of pre-painted, galvanized steel with baked enamel
finish.
Cooling systems have low and high-pressure switches. Two-inch
disposable type return air filters are factory installed.
Provision for alternate end return in base unit. Horizontal supply
available by using accessory curb. EconoMi$er may be used with
horizontal supply and return.
Direct drive propeller condenser fans with vertical discharge.
2-stage gas heat in a single 2-stage gas valve.
Induced draft combustion system with Hall effect sensor to detect
proper operation of induced-draft motor.
Heavy Alumagard coated heat exchangers with aluminized steel
burners.
Optional stainless steel heat exchangers.
Heating controls with solid-state direct spark ignition system (pilotless
system) and redundant gas valve. High temperature limit switches and
auto-reset flame rollout switch are standard.
Reliable IGC (integrated gas unit controller) with built in diagnostics
to determine error codes and control fan on/off delays for energy
savings and maximum comfort control.
Integrated gas unit controller provides anti-cycle protection for gas
heat operation.
PERFORMANCE DATA
Unit Operating Weight ___________________________________lb
COOLING
Gross Total Capacity _________________________________ Btuh
@ Condenser Air Temperature ___________________________ F
Gross Sensible Capacity _______________________________ Btuh
Compressor Power Input _______________________________ kW
Indoor Entering db _____________ F wb _______________ F
Airflow ___________ External Static Pressure ___________ in. wg
Indoor Fan Motor Size _________________________________ Hp
Exhaust Fan Motor Size ________________________________ Hp
Curb Weight ___________________________________________lb
HEATING
Heating Capacity:
Stage 1 ____________________________________________ Btuh
Stage 2 ____________________________________________ Btuh
Heating Capacity Total ________________________________ Btuh
Stage 1 _____________________________________________ kW
Stage 2 _____________________________________________ kW
Heating Capacity Total _________________________________ kW