Carrier 48XL User Manual

Browse online or download User Manual for Split-system air conditioners Carrier 48XL. Product Data - HVACpartners

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
48XL/ 48XLN
Infinityt 15 SEER Single---P ackaged
Air Conditioner and Gas Furnace System
w/PuronR (R---410A) Refrige rant
2---5 Nominal Tons (Sizes 024---060)
Product Data
A05307
Fig. 1 -- Unit 48XL
Single--Packaged Products with Energy --Saving Features and
Puron
®
refrigerant.
S Direct Spark Ignition
S Up to 15.5 SEER
S Meets Energy Star requirements
S Up to 80.1% AFUE
S Low Sound Levels
S Variable--Speed Blower (Standard)
S Factory Installed TXV
S Stainless Steel Heat Exchanger (Limited Lifetime Warranty)
S Two Stage Cooling and Heating
FEATURES/BENEFITS
One-- piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
Puro n
®
Environmentally -- Sound Refrigerant is Carrier’s unique
refrigerant designed to help protect the environment. Puron
refrigerant is an HFC refrigerant which does not contain chlorine
that can harm the ozone layer. Puron refrigerant is in service in
millions of systems proving highly reliable, environmentally sound
performance.
IdealHumidityt Technology featuring Infinityt control and
Variable--Speed Blower motor and two--stages of cooling and
heating provide greater comfort, humidity control, and energy
efficiency .
Variable--Speed Blower motors provide better comfort and
energy efficiency . You can expect up to 30 times better
dehumidification; economical constant fan for less than $50 a year,
which provides improved indoor air quality and more even
temperatures from room to room; and reduced indoor noise due to
lower air velocity. In addition, you’ll realize improved installation
flexibility with 3 different airflow choices for best overall comfort.
Easy installation
Factory --assembled package is a compact, fully self-- contained,
combination gas heating/electric cooling unit that is pre-- wired,
pre--piped, and pre-- charged for minimum installation expense.
These units are available in a variety of standard and optional
heating/cooling size combinations. Units are lightweight and install
easily on a rooftop or at ground level. The high tech composite unit
base eliminates rust problems associated with ground level
applications.
Convertible duct configuration
Unit is designed for easy use in either downflow or horizontal
applications. Each unit is easily converted from horizontal to
downflow and includes horizontal duct covers. Downflow
operation is easily provided in the field to allow vertical ductwork
connections. The basepan utilizes knockout style seals on the
bottom openings to ensure a positive seal in the horizontal airflow
mode.
Efficient operation
High--efficiency design with SEERs (Seasonal Energy Efficiency
Ratio) o f up to 15.5 and AFUE (Annual Fuel Utilization
Efficiency) ratings as high at 80.1%.
Energy--saving, direct spark ignition saves gas by operating only
when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low--cost field installed kit
for propane conversion is available for all units.
48XLN units are dedicated Low NOx units designed for
California installations. These models meet the California
maximum oxides of nitrogen (NOx) emissions requirement of 40
nanograms/joule or less as shipped from the factory and MUST be
installed in California Air Quality Management Districts or any
other location where a Low NOx rule exists.
Durable, dependable components
Compr essors have two stages of cooling and are designed for high
efficiency . Each compressor is hermetically sealed against
contamination to help promote longer life and dependable
operation. Vibration isolation provides quiet operation.
Compressors have internal high --pressure and overcurrent
protection.
Page view 0
1 2 3 4 5 6 ... 25 26

Summary of Contents

Page 1 - Product Data

148XL/ 48XLNInfinityt 15 SEER Single---P ackagedAir Conditioner and Gas Furnace Systemw/PuronR (R---410A) Refrige rant2---5 Nominal Tons (Sizes 024---

Page 2

10ACCESSORY DIMENSIONSGask et aroundouter edgeInsulateddeck panGask et aroundductS/AR/AHVAC unitbase*Gask etingouter flangeFlashing fieldsuppliedR

Page 3 - MODEL NUMBER NOMENCLATURE

1148XL RIGGING WEIGHTS-in. (914 mm)DETAIL A A06298A06296CABINETMODELRIGGING WEIGHTlb kgSmall 48XL--024 420 191Small 48XL--030 427 194Large48XL--036 51

Page 4 - ARI* CAPACITIES

12PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL024 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F(_C

Page 5 - PHYSICAL DATA

13PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL030 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F(_C

Page 6 - PHYSICAL DATA (CONT)

14PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL036 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F(_C

Page 7 - MANUAL OUTSIDE AIR DAMPER

15PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL042 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F(_C

Page 8

16PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL048 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F(_C

Page 9

17PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table48XL060 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _F(_C

Page 10 - ACCESSORY DIMENSIONS

18PERFORMANCE DATA (CONT)LEGENDBF— Bypass Factoredb— Entering Dry --- BulbEwb — Entering Wet---BulbkW — Total Unit P ower Inputldb— Leaving Dry---Bulb

Page 11 - SELECTION PROCEDURE

19PERFORMANCE DATA (CONT)Wet coil air delivery -- low stage208/230 VOLTUNITSIZESYSTEM SETTINGEXTERNAL STATIC PRESSURE (IN. W.C.)0.1 0.2 0.3 0.4 0.5 0.

Page 12 - 48XL024 Low Cool

2Monoport inshot burners produce precise air--to--gas mixture,which provides for clean and efficient combustion. The largemonoport on the inshot (or i

Page 13 - 48XL030 Low Cool

20TYPICAL PIPING AND WIRINGROOFRETURN-AIRFLEXIBLE DUCTCEILINGCONCENTRIC DIFFUSER BOX(FIELD-SUPPLIED)SUPPLY-AIRFLEXIBLE DUCTROOF-MOUNTINGCURBC00023USER

Page 14 - 48XL036 High Cool

21APPLICATION DATACondensate trap — A 2--in. (51 mm) condensate trap must be fieldsupplied.1” (25 mm) MIN.2” (51 mm) MIN.TRAPOUTLETDuctwork — Secure d

Page 15 - 48XL042 Low Cool

22TYPICAL WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 040, 060, 090 kBtu/hrA0841948XL

Page 16 - 48XL048 Low Cool

23TYPICAL WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 115, 130 kBtu /hrA0842048XL

Page 17 - 48XL060 Low Cool

24CONTROLSSequence of OperationCooling Operation—With a call for first stage cooling, the outdoorfan and low--stage compressor are energized. If low--

Page 18 - PERFORMANCE DATA (CONT)

25GUIDE SPECIFICATIONSSINGLE--PACKAGED GAS HEATING/ELECTRIC COOL-ING UNITS CONSTANT VOLUME APPLICATIONHVAC GUIDE SPECIFICATIONSSIZE RANGE: 2 TO 5 TONS

Page 19

26GUIDE SPECIFICATIONS (CONT)M. Grille1. Louvered Grille:Louvered grille shall be factory--installed to provide hailguard and vandalism protection.N.

Page 20 - TYPICAL PIPING AND WIRING

3TABLE OF CONTENTSFEATURES/BENEFITS 1--2...MODEL NUMBER NOMENCLAT

Page 21 - ELECTRICAL DATA

4ARI* CAPACITIESCooling Capacities, EfficienciesUnit 48XL Nominal TonsStandard CFM(High / Low Stage)Net CoolingCapacities (Btuh)(High / Low Stage)EER

Page 22

5PHYSICAL DATAUNIT SIZE 024040 024060 030040 030060 036060 036090 042060 042090NOMINAL COOLONG CAPACITY (ton) 2 2 2 --- 1 / 2 2 --- 1 / 2 3 3 3 --- 1

Page 23

6PHYSICAL DATA (CONT)UNIT SIZE 048090 048115 048130 060090 060115 060130NOMINAL COOLING CAPACITY (ton) 4 4 4 5 5 5NOMINAL HEATING CAPACITY (Btu) 90,00

Page 24 - CONTROLS

7OPTIONS AND ACCESSORIESFactory--installed optionsCoil options include tin --plated* indoor hairpins, copper/copperand vinyl--coated construction for

Page 25 - GUIDE SPECIFICATIONS

8A06608Fig. 2 -- 48XL024--030 Unit Dimensions48XL

Page 26 - Catalog No: 48XL---06PD

9A07900Fig. 3 -- 48XL036--060 Unit Dimensions48XL

Comments to this Manuals