Product DataGA SeriesPackaged Terminal Air Conditioner / Heat Pump7,000 --- 15,000 Btuh

Page 2 - TABLE OF CONTENTS

10WALL THERMOSTAT INTERFACEThe standard wall thermostat interface provides asimple to install thermostat connection. The unit hasa removable terminal

Page 3 - QUICK SPECIFICATIONS

11POWER CORD PROTECTION FOR230/208V UNITSThe power cord for the 208/230--v unit providespower cord protection by automaticallydisconnecting power duri

Page 4

12SEAMLESS BASEPANSeamlessdrawnbasepanwallsaddprotectionagainstwateraccumulationresulting fromstorm--drivenrainwith heavy wind.Gree’s deep basepan hol

Page 5

13CORROSION PROTECTIONTo protect against the corrosive effects of a seacoastenvironment, this option includes:• A standard chassis with front panel• S

Page 6 - PTAC-GA E 12 AB

14HEAT PUMPS PAY THEIROWN WAYHeat pump models are available at a nominaladditional cost. In many locales, the payback isrealized in just a few months.

Page 7 - PRODUCT OVERVIEW (GA Series)

15HEAT PUMP ENERGYSAVINGSHeat pumps save more on operating costs during theh eating cycle thanheat/cool models. The tablebelowshows that the higher in

Page 8

16FIELD--INSTALLED ACCESSORIESWALL SLEEVESImportant Sleeve Installation Consid erations:• All Gree sleeves are self pitching and mustbe mounted level

Page 9 - Condensate Removal

17FIELD--INSTALLED ACCESSORIES (CONT.)Insulated Metal Wall SleevesPart No.: SLEEVE--STEEL--1PKPart No.: SLEEVE--EXT18--1PKPart No.: SLEEVE--EXT24--1PK

Page 10 - RETROFIT/REPLACEMENT

18FIELD--INSTALLED ACCESSORIES (CONT.)OUTDOOR GRILLESAluminum ArchitecturalOutdoor Grilles (Louvered)Part No.: GRILLE--ALU--CLEAR (anodized aluminum)P

Page 11 - APPLICATION CONSIDERATIONS

19FIELD--INSTALLED ACCESSORIES (CONT.)OUTDOOR GRILLE SELECTIONIMPORTANT: If you wish to use a grille not madefor the Gree GA series contact Gree

Page 12

2GATABLE OF CONTENTSPAGEQUICK SPECIFICATIONS 3...APPLICATIONS 4--5...4noitcurtsnoCweN ...

Page 13 - CORROSION PROTECTION

20FIELD--INSTALLED ACCESSORIES (CONT.)SUBBASEPart No.: SUBBASE--230V--15APart No.: SUBBASE--230V--20APart No.: SUBBASE--230V--30APart No.: SUBBASE--26

Page 14 - HEAT PUMPS PAY THEIR

21FIELD--INSTALLED ACCESSORIES (CONT.)Leveling LegsPart No.: LEVELING--LEGSLeveling legs attach easily to the wall sleeve andoffer accurate le

Page 15 - HEAT PUMP ENERGY

22FIELD--INSTALLED ACCESSORIES (CONT.)THERMOSTATSNon--Programmable ThermostatPartNo.:TT-N-411 (Heat / Cool Models)Part No.: TT-N-421 (Heat Pump Models

Page 16 - FIELD--INSTALLED ACCESSORIES

23FIELD--INSTALLED ACCESSORIES (CONT.)Condensate Drain KitPart No.: DRAIN--KIT--4PKThe drain kit may be attached to the exterior right orleft side of

Page 17 - Amounts in ( ) = mm

24DIMENSIONAL DRAWINGS AND INSTALLATION DATA -- NEWCONSTRUCTIONP roper building practices must b e used whenconstructing a wall opening to support a P

Page 18

25DIMENSIONAL DRAWINGS AND INSTALLATION DATACONTINUEDVOLTAGE CURRENT DIMENSIONS --- Inches (mm) PLUG TYPEVOLTS AMPS XYZNEMA PLUGNEMARECEPTACLESUPPLIER

Page 19 - OUTDOOR GRILLE SELECTION

26DIMENSIONAL DRAWINGS AND INSTALLATION DATA --NEW CONSTRUCTION (CONT.)WALL SLEEVE MOUNTING DIMENSIONS FOR STANDARD AND ACCESSORY GRILLES42”(1067 mm)1

Page 20

27TYPICAL WALL INSTALLATION5/8”(15.9 mm)A07384Typical Wall Sleeve InstallationNOTES:1. Sleeve may be flush mounted to floor, but frontpanel may have t

Page 21

A0738652M Indoor and Outdoor Discharge AirCirculation36" (914.4 mm) MINIMUM DISTANCE FROMSLEEVE TO BUILDING WALLS,SHRUBS, etc.15” (381.0 mm) MIN

Page 22

29DIMENSIONAL DRAWINGS AND INSTALLATION DATA --NEW CONSTRUCTION (CONT.)TYPICAL SUBBASE INSTALLATION0’-0 7/8”(22)SUBBASE ACCESS COVERS0’-3 1/4” MIN. (8

Page 23

Always look for these symbols, the air conditioning industry seals of certified performance, efficiencyp y3QUICK SPECIFICATIONSCOOLING & ELECTRIC

Page 24 - CONSTRUCTION

30WALL THERMOSTAT CONNECTIONSR Y GH GL C W O CommonEnergy Management (24VAC in)TYPICAL WALL THERMOSTATTERMINAL BLOCKSee Note 1See Note 2NOTES:1. Use

Page 25 - CONTINUED

31PERFORMANCE AND ELECTRICAL DATALEGENDEER — Energy Efficiency Ratio* Rated in accordance with ARI Standard 380-93.† See power cord selection guide be

Page 26 - NEW CONSTRUCTION (CONT.)

32PERFORMANCE AND ELECTRICAL DATA (CONT.)LEGENDEER — Energy Efficiency Ratio* Rated in accordance with ARI Standard 380-93.† See power cord selection

Page 27 - TYPICAL WALL INSTALLATION

33PERFORMANCE AND ELECTRICAL DATA (CONT.)LEGENDEER — Energy Efficiency Ratio* Rated in accordance with ARI Standard 380-93.† See power cord selection

Page 28

34PERFORMANCE AND ELECTRICAL DATA (CONT.)LEGENDEER — Energy Efficiency Ratio* Rated in accordance with ARI Standard 380-93.† See power cord selection

Page 29

35INDOOR FAN PERFORMANCE DATAModel VoltageDry CFM* Wet CFM*Low Medium High Low Medium High208 235 250 270 220 235 250230 260 280 300 240 260 280265 26

Page 30 - R W Y O Gh Gl C

36INDOOR SOUND POWER DATAIndoor Sound Estimating Table (dBA and BELS)OperatingModeVoltsNOMINAL SIZES (dBA) NOMINAL SIZES ( BELS)GAA GAEGAAGAE7000 9000

Page 31

37OUTDOOR SOUND POWER DATAOutdoor Sound Estimating Table (dBA and BELS)OperatingModeVoltsNOMINAL SIZES (dBA) NOMINAL SIZES ( BELS)GAA GAE GAA GAE7000

Page 32

38WIRING SCHEMATICGAA08389GA Series -- Typical Wiring Schematic for Standard Units*NOTE: Dashed area above shows REVERSING VALVE. It is found only in

Page 33 - MODEL PTAC-GAA (208/230-1-60)

39TYPICAL WIRING SCHEMATIC FOR ENERGYMANAGEMENT INTERFACEFRONT DESK SWITCH PANEL24-VTRANSFORMER(SEE NOTE 1)PTAC #1PTAC #2PTAC #NN MOOR101 MOOR001 MOOR

Page 34 - MODEL PTAC-GAA (265-1-60)

APPLICATIONS• Hotels and motels• Nursing homes and assisted living carecenters• Offices• Apartments• Single--family dwellings• Home conversions and re

Page 35 - INDOOR FAN PERFORMANCE DATA

40TYPICAL WIRING SCHEMATIC FOR MULTIPLE P TAC UNITSCONNECTED TO A SINGLE WALL THERMOSTATRYWGOCRYWGOCRYWGOCRYWGOCRYWGOCT’STATMASTERPTACUNIT 1UNIT 2UNIT

Page 36 - INDOOR SOUND POWER DATA

41PACKAGED TERMINAL COOLING UNITWITH HEAT PUMP OR ELECTRIC HEATINGHVAC Guide SpecificationsSize Range:Cooling: 7,600 to 15,000 Btuh (2051 to 4396 WH)E

Page 37 - OUTDOOR SOUND POWER DATA

42E. Air Flow S ys tem:For superior sound and comfort, the airflowsystem shall consist of two, direct--drivepermanently lubricated fan motors. The out

Page 38 - ADVANTAGES FOR NEW

Hardwire kit (PN: HARDWIRE-KIT-xxA) shall be required if an accessory power cord is not used. The hardwire kit provides a permanent connection to the

Page 39

443.0 DELIVERY, ST ORAGE, ANDHANDLINGThe packaging of the chassis shall be sufficie nt top rotect the chassis from dam ageduring shipment viaan enclos

Page 40

5APPLICATION CONSIDERATIONSInstallation instructions are shipped with all PTACunits. It is important that air conditioning systems beproperly sized an

Page 41 - Part 2—Chassis D escription

6PRODUCT CATALOG NUMBER-NOMENCLATURECooling Capacity (nominal)07 – 7,000 Btuh09 – 9,000 Btuh12 – 12,000 Btuh15 – 15,000 BtuhPTAC-GA E 12 ABDS

Page 42

7PRODUCT OVERVIEW (GA Series)This section summarizes product features covered in detail in later sections of this manual.FRONTPANELINDOORCOILBASEPANDI

Page 43

8NO--RUST WALL SLEEVEAND FRONT PANELThe indoor front panel and polymer wall sleeve usenonmetallic compounds that never rust or corrode, donot support

Page 44

9OUTDOOR AIR VENTILATIONThe vent will provide up to 65 cfm of fresh air.A07550Outdoor Air VentilationBI--DIRECTIONAL DISCHARGEGRILLEThe discharge gril