Carrier G Series Heating Service Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
1-6
T -310
1.3 System Operating Controls And
Components
There are five controls on the driver’s station which
affect the operation of the Carrier supplied equipment
covered by this manual. These controls include two
rocker switches, two slide switches, and the Micromate
Control Panel. (Figure 1-6)
The first rocker switch (1 Figure 1-6) is the drivers
On/Off/Defrost switch which controls the power to the
control circuit for the entire system. The first slide
switch (2) is labeled the Defrost Switch. This switch
controls the driver evaporator blower motor speed. The
second slide switch (3) is labeled the Heat Switch. This
switchcontrolsthedriverevaporatorcoolantvalve. The
second rocker switch (4) is labeled the Parcel Rack.
This switch will activate the parcel rack evaporators if
the passenger evaporator is in operation.
The fifth control is the Micromate Control Panel
(Figure 1-7 or Figure 1-8) which operates the Carrier
Transicold Micromax microprocessor controller, logic
board (Figure 1-10), relay board (Figure 1-9), circuit
breakers and relays (Figure 1-11). The logic board
regulates the operational cycles of the system by
energizing or de--energizing components in response to
deviations in interior temperature. Modes of operation
include Auto, Cool, Heat and Vent.
The Micromate Control Panel (supplied in one of two
configurations) is installed in the upper l eft hand switch
panel. One configuration (Figure 1-7) will allow the
driver to turn the system on and off, access outside and
interior return air temperatures, and adjust interior
temperature setpoint. With this configuration, system
diagnostics will need to be performed with the
Micromate Diagnostic Service Tool (P/N
76-62124--01). The other configuration (Figure 1-8)
will perform the same functions and also allow the
driver to control all the system functions manually. In
addition this configuration will allow the service
technician to view system parameters and alarms.
With the Micromatein the AUTO mode, the logic board
will cycle the system between the operating modes as
required to maintain desired set point temperature.
In the VENT mode the evaporator fans are operated to
circulate air in the bus interior.
In the HEAT mode the heat valve(EHV), the OEM
supplied boost pump and auxiliary heater are energized.
The evaporator fans operate to circulate air over the
evaporator coil in the same manner as the vent mode.
In the COOL mode the compressor is energized while
the evaporator and condenser fans are operated to
provide refrigeration as required. The compressor is
fitted with cylinder unloaders to match compressor
capacity to the bus requirements. Once interior
temperature reaches the desired set point, the system
mayoperateineither the clutch cycleor reheat mode(set
at the factory, choosen as part of the purchase
agreement). A controller programmed for reheat will
maintain compressor operation and open the heat
valve(EHV) to allow reheating of the return air. In the
reheat mode interior temperature i s m aintained at the
desired set point while additional dehumidification
takes place. A controller programmed for clutch cycle
will de--energize the compressor clutch and allow t he
system to operate in the vent mode until further cooling
is required.
1.3.1 Other Carrier Supplied Items
Other Carrier supplied items include driver and
passenger interior return air temperaturesensors, andan
ambient temperature sensor. The temperature sensors
provide input to the controller on temperature
conditions in the applicable zone.
1. System On/Off/Defrost
2. Defrost(Driver’s Evap. Blower)
3. Heat(Driver’s Evap. Coolant Valve)
4. Parcel Rack On/Off
5. Micromate Control Panel
5
1
2
3
4
Figure 1-6. System Operating Controls
(upper left hand switch panel)