Carrier 58MTB User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
16
58MTB
MAXIMUM ALLOWABLE PIPE LENGTH (FT) (Continued)
ALTITUDE (FT)
UNIT SIZE
(BTUH)
DIRECT VENT (2-PIPE) ONLY
NON-DIRECT VENT
(1-PIPE) ONLY
NUMBER OF 90° ELBOWS
TERMINATION
TYPE
PIPE DIA
(IN.)*
PIPE DIA
(IN.)*
12 3 4 5 6
7001 to 8000‡
60,000
2 Pipe or 2-in
Concentric
1-1/2 1-1/2 12 7 NA NA NA NA
2253 48 46 41 40 38
80,000
2 Pipe or 2-in
Concentric
2236 31191412NA
2-1/2 2-1/2 66 65 63 62 60 59
100,000
2 Pipe or 3-in
Concentric
2-1/2 2-1/2 25 17 8 7NANA
3363 58 53 48 4338
120,000
2Pipeor3-in.
Concentric
3†nodiskNA2013 7NANANA
NA 3†464443 41 40 38
4† no disk4nodisk615651464136
ALTITUDE (FT)
UNIT SIZE
(BTUH)
DIRECT VENT (2-PIPE) ONLY
NON-DIRECT VENT
(1-PIPE) ONLY
NUMBER OF 90° ELBOWS
TERMINATION
TYPE
PIPE DIA
(IN.)*
PIPE DIA
(IN.)*
12 3 4 5 6
8001 to 9000‡
60,000
2 Pipe or 2-in
Concentric
1-1/2 1-1/2 11 6 NA NA NA NA
224944423
7 35 34
80,000
2Pipeor2-in
Concentric
2233 28 17 12 10 NA
2-1/2 2-1/2 62 60 58 56 55 53
100,000
2Pipeor3-in
Concentric
2-1/2 2-1/2 23 15 7 5 NA NA
3359 54 49 44 39 34
120,000
2Pipeor3-in.
Concentric
3†nodisk NA 10NANANANANA
NA 3†43 41 39 37 35 34
4† no disk4nodisk 35 3025201510
ALTITUDE (FT)
UNIT SIZE
(BTUH)
DIRECT VENT (2-PIPE) ONLY
NON-DIRECT VENT
(1-PIPE) ONLY
NUMBER OF 90° ELBOWS
TERMINATION
TYPE
PIPE DIA
(IN.)*
PIPE DIA
(IN.)*
12 3 4 5 6
9001 to 10,000‡
60,000
2Pipeor2-in
Concentric
22454038 33 3129
80,000
2Pipeor2-in
Concentric
223025 14 9 7 NA
2-1/2 2-1/2 57 55 53 51 49 47
100,000
2Pipeor3-in
Concentric
2-1/2 2-1/2 21 13
5 NANANA
3354 49 44 39 3429
120,000
2Pipeor3-in.
Concentric
NA 3 39 37 35 33 3129
4† no disk4nodisk 10 5 NA NA NA NA
*Disk usage-Unless otherwise specified, use perforated disk assembly (factory-supplied in loosepartsbag).Ifonediskisstated, separate 2 halves of perforated dis
k
assembly and use shouldered diskhalf. When using shouldered diskhalf, install screen side toward inlet box.
†Wide radius elbow.
‡Vent sizing for Canadianinstallations over 4500 ft (1370 m) above sea level are subject to acceptance bythelocal authorities having jurisdiction.
NA-Not Allowed; pressure switch will not make.
NOTES:
1. Do not us
e pipe size greater thanthose specified in table or incomplete combustion, flame disturbance, or flame senselockoutmay occur.
2. Size both the combustion-air and vent pipe independently, then usethelarger diameter for both pipes.
3.Assume two 45° elbows equal one 90° elbow.Wideradius elbowsare desirable and may berequired in some cases.
4. Elbowsand pipe section
s within the furnace casing and at the vent termination should not beincluded in vent length or elbow count.
5. The minimum pipe length is 5ftforall applications.
6. Use 3-in. diameter vent termination kit for installations requiring 4-in diameter pipe.
Combustion-air and vent piping for Direct Vent (2-Pipe)
and Non-Direct Vent (1-Pipe) Applications
Page view 15
1 ... 15 16 17 18 19 20 21 22

Comments to this Manuals

No comments