Carrier Packaged Terminal s & Heat Pumps 52P User Manual

Browse online or download User Manual for Conditioners Carrier Packaged Terminal s & Heat Pumps 52P. Carrier Packaged Terminal s & Heat Pumps 52P User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ARCHITECTS AND ENGINEERS’ MANUAL
April 2006 Copyright Carrier Corporation Cat. No. 592-085
CONTENTS
Page
APPLICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,4
New Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Retrofit/Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Carrier Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Application Considerations . . . . . . . . . . . . . . . . . . . . . . 4
PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . 5
PRODUCT FEATURES AND BENEFITS . . . . 6-13
Quiet Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Most Efficient Performance . . . . . . . . . . . . . . . . . . . . . . 6
Efficient Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
No-Rust Weather Last™ Wall Sleeve and
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Removable Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . 7
Anti-Theft Knobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Two-Piece Lifetime Indoor Filter. . . . . . . . . . . . . . . . . . 8
Washable Vent Air Filter . . . . . . . . . . . . . . . . . . . . . . . . 8
Bi-Directional Discharge Grille . . . . . . . . . . . . . . . . . . . 8
Power Cord for 265-V Units . . . . . . . . . . . . . . . . . . . . . 9
Power Cord Protection for 230/208-V Units . . . . . . . . . 9
Bi-Molded Condenser Shroud . . . . . . . . . . . . . . . . . . . . 9
Snow Baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Easy Access to Chassis. . . . . . . . . . . . . . . . . . . . . . . . . 10
Hidden Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Enhanced Copper Tubing . . . . . . . . . . . . . . . . . . . . . . . 11
Page
Seamless Basepan . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Condensate Drain Valve. . . . . . . . . . . . . . . . . . . . . . . . 11
Condensate Removal System. . . . . . . . . . . . . . . . . . . . 11
Heat Pumps Pay Their Own Way. . . . . . . . . . . . . . . . . 12
Heat Pump Energy Savings . . . . . . . . . . . . . . . . . . . . . 13
ORDERING DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Product Catalog Number . . . . . . . . . . . . . . . . . . . . . . . 14
FACTORY-INSTALLED OPTIONS . . . . . . . . . . . 15
FIELD-INSTALLED ACCESSORIES . . . . . . 16-26
DIMENSION DRAWINGS AND
INSTALLATION DATA — NEW
CONSTRUCTION. . . . . . . . . . . . . . . . . . . . . . . . . 27-33
PRODUCT DATA . . . . . . . . . . . . . . . . . . . . . . . . . 34-41
EXPANDED RATINGS DATA. . . . . . . . . . . . . . .42,43
SOUND DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . 45-50
52PQ and 52CQ . . . . . . . . . . . . . . . . . . . . . . . . . . . .45,46
52PE and 52CE . . . . . . . . . . . . . . . . . . . . . . . . . . . .47,48
Energy Management/Front Desk Control . . . . . . . . . . 49
Single Thermostat/Multiple PTAC Units . . . . . . . . . . . 50
GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . 51-53
TYPICAL WARRANTY . . . . . . . . . . . . . . . . . . . .54,55
ACCESSORY LIST . . . . . . . . . . . . . . . . . . . . . . . . . . 56
For more information available on the internet, see the www.carrier.com or www.lodgingAC.com web sites.
PREMIER SERIES 52P
COMFORT SERIES 52C
PACKAGED TERMINAL
AIR CONDITIONERS
AND HEAT PUMPS
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - COMFORT SERIES 52C

ARCHITECTS AND ENGINEERS’ MANUALApril 2006 Copyright  Carrier Corporation Cat. No. 592-085CONTENTSPageAPPLICATIONS . . . . . . . . . . . . . . . . .

Page 2

10EASY ACCESS TO CHASSISAccess to the chassis simply requires removing fourscrews and then sliding the chassis out of the sleevefor service. HIDDEN CO

Page 3 - APPLICATIONS

11ENHANCED COPPER TUBINGEnhanced copper tubing is more efficient and durableand can be repaired in the field, if required.Because copper is a very sta

Page 4 - APPLICATIONS (cont)

12HEAT PUMPS PAY THEIR OWN WAYHeat pump models are available at a nominal addi-tional cost. In many locales, the payback is realized injust a few mont

Page 5

13HEAT PUMP ENERGY SAVINGSCARRIER HEAT PUMP INITIAL COST VERSUS SAVINGS OVER HEAT/COOL MODELS LEGEND*Computer projections based on full coolin

Page 6 - (52P AND 52C)

14For immediate assistance, call 1-800-827-7435 or contactyour local Carrier dealer.Standard Unit• Chassis with front panel• Electro-mechanical contro

Page 7 - ANTI-THEFT KNOBS

15WALL THERMOSTAT CONTROL (RC,RP)Carrier’s wall thermostat control option includes:• a standard chassis with front panel• factory-installed low voltag

Page 8 - DISCHARGE GRILLE

16WALL SLEEVESWeather Last™ Wall SleeveFor the best performance and longest life, Carrierrecommends genuine Carrier wall sleeves for allinstallations.

Page 9 - CONDENSER

17Insulated Metal Wall SleevesPart No.: SLEEVE-STEEL-1PK Part No.: SLEEVE-EXT18-1PK Part No.: SLEEVE-EXT24-1PK Part No.: SLEEVE-EXT26-1PK Part No.: SL

Page 10 - Easy Service Access

18OUTDOOR GRILLESCarrier recommends only the use of Carrier-suppliedgrilles for use on the 52P and 52C series units. How-ever, the architectural desig

Page 11 - CONDENSATE REMOVAL

19Outdoor Grille SelectionThe following guidelines must be followed in the ini-tial selection of any alternate exterior grille or louver:1. The louver

Page 12 - HEAT PUMPS PAY THEIR

2Valued Carrier Customer,Carrier’s Architects and Engineer’s manual has been specifically developed to make yourproduct and accessory selection easier

Page 13 - HEAT PUMP ENERGY

20SUBBASEThis decorative subbase supports the unit and is avail-able in three basic models: non-electrical, electrical,and hardwired.A subbase (or lev

Page 14 - ORDERING DATA (52P AND 52C)

21Leveling LegsPart No.: LEVELING-LEGSLeveling legs attach easily to Carrier’s wall sleeve andoffer accurate leveling and support for units without as

Page 15 - CORROSION PROTECTION

22THERMOSTATSCarrier’s full line of wall thermostats are designed toenhance every PTAC application. Wall thermostats aresimple and easy to use. Wall t

Page 16

23Wall Thermostat Interface Retrofit KitPart No.: RC-FIELDKIT230HCPart No.: RC-FIELDKIT230HPPart No.: RC-FIELDKIT265HCPart No.: RC-FIELDKIT265HPThe wa

Page 17 - Wall Sleeve Molding Kit

24Condensate Drain KitPart No.: DRAIN-KIT-4PKThis universal drain kit may be used internally orexternally to route condensate to a drainage system. It

Page 18 - (52P AND 52C) (cont)

25Power Vent with Power Door Kit Part No.: PWR-VENT-DOOR230Part No.: PWR-VENT-DOOR265Carrier's power vent kit, utilizing a specially designedfan,

Page 19 - Conduit Interface Kit

26Replacement FiltersPart No.: AIR-FILTER-10PKThe Carrier 52P and 52C model replacement air filterscome in packages of 10. The filters save energy by

Page 20

27TYPICAL WALL INSTALLATIONProper building practices must be used when con-structing a wall opening to support a PTAC wall sleeveand chassis.If practi

Page 21 - Subbase Power Disconnect

28WALL SLEEVE MOUNTING DIMENSIONS FOR STANDARD AND ACCESSORY GRILLESMAIN STUDJACK STUDCRIPPLEFLOORSUB-FLOOR42 1/8”16 1/4”JACK STUDSHEADER- 4’ x 4’ OR(

Page 22

29TYPICAL WALL INSTALLATIONNOTES:1. Sleeve may be flush mounted to floor, but front panel may haveto be notched to accommodate service cord.2. If more

Page 23 - Thermostat Locking Cover

3Whether you are designing a new structure or replac-ing packaged terminal air conditioning units in anexisting building, Carrier will meet your needs

Page 24

30MINIMUM CLEARANCE FOR INDOOR ANDOUTDOOR DISCHARGE AIR 36" MINIMUM DISTANCE FROMSLEEVE TO BUILDING WALLS,SHRUBS, etc.15” MINIMUM DISTANCE FROMFR

Page 25 - Security Door Kit

31TYPICAL LATERAL DUCT INSTALLATION3’-11 1/2”(1206.5)MAX.3’-11 1/2”(1206.5)MAX.3’-8”(117.6)WALLMOLDINGWALLREGISTERLATERAL DUCTEXTENSIONREVERSIBLEAIR G

Page 26

3252P AND 52C WITH SUBBASE0’-0 7/8”(22)SUBBASE ACCESS COVERS0’-3 1/4” MIN. (83)0’-5 1/2” MAX. (140)OUTSIDEWALLSIDESUBBASE LEVELING BOLTSACCESSORY DRAI

Page 27 - DATA — NEW CONSTRUCTION

33WALL THERMOSTAT CONNECTIONSPOWERCORDACCESSCOVERPOWER CORDFAN SPEEDCONTROLKNOBTHERMOSTAT WIRE (FIELD-SUPPLIED)RGYWOCTHERMOSTATRGYWOCTHERMOSTAT WIRE R

Page 28 - AND ACCESSORY GRILLES

34PERFORMANCE AND ELECTRICAL DATAMODEL 52PQ (230/208-1-60) LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standar

Page 29 - TYPICAL WALL INSTALLATION

35PERFORMANCE AND ELECTRICAL DATAMODEL 52PQ (265-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 380-93.†Coefficient of

Page 30 - OUTDOOR DISCHARGE AIR

36PERFORMANCE AND ELECTRICAL DATAMODEL 52PC AND PE (230/208-1-60)52PC performance and electrical data is the same as 52PE without electric heat.LEGEND

Page 31 - 52P and 52C Lateral Duct

37PERFORMANCE AND ELECTRICAL DATAMODEL 52PC AND PE (265-1-60)52PC performance and electrical data is the same as 52PE without electric heat.LEGENDEER

Page 32 - 52P AND 52C WITH SUBBASE

38PERFORMANCE AND ELECTRICAL DATAMODEL 52CQ (230/208-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 380-93.†Coefficien

Page 33 - WALL THERMOSTAT CONNECTIONS

39PERFORMANCE AND ELECTRICAL DATAMODEL 52CQ (265-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 380-93.†Coefficient of

Page 34 - PRODUCT DATA (52P)

4APPLICATIONCONSIDERATIONSInstallation instructions are shipped with all PTACunits. It is important that air conditioning systems beproperly sized and

Page 35 - RECEPTACLES AND FUSE TYPES

40PERFORMANCE AND ELECTRICAL DATAMODEL 52CE (230/208-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310-93.†Electric r

Page 36 - PRODUCT DATA (52P) (cont)

41PERFORMANCE AND ELECTRICAL DATAMODEL 52CE (265-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310-93.†Electric resis

Page 37

42COOLING PERFORMANCEALL 7000 NOMINAL BTUH MODELSEvaporator entering air temp. — 80 F Evap. air — 260 CFMLEGENDNOTES:1. Total current (I) based on 230

Page 38 - PRODUCT DATA (52C)

43COOLING PERFORMANCE (cont)52PQ 12,000 NOMINAL BTUH MODELSEvaporator entering air temp. — 80 F Evap. air — 350 CFMLEGENDNOTES:1. Total current (I) ba

Page 39

44INDOOR SOUND DATA (52P AND 52C)The tables below indicate the approximate indoor andoutdoor sound levels. Tests were conducted in theCarrier Sound Te

Page 40 - PRODUCT DATA (52C) (cont)

45WIRING DIAGRAMS (52P AND 52C)52PQ and 52CQ — Typical Wiring Schematic for Standard Heat Pump UnitsCOMPONENT LEGENDComponent Connection (Marked)Compo

Page 41

46WIRING DIAGRAMS (52P AND 52C) (cont)TYPICAL THERMOSTAT INTERFACE1. If ‘W’ is ON, then ‘FR’ is forced ON (regardless of ‘G’) and ‘CR’ is forced OFF.2

Page 42 - COOLING PERFORMANCE

4752PE and 52CE — Typical Wiring Schematic for Standard Heat/Cool UnitsCOMPONENT LEGENDComponent Connection (Marked) FM — Fan MotorComponent Connectio

Page 43 - COOLING PERFORMANCE (cont)

48WIRING DIAGRAMS (52P AND 52C) (cont)52PE and 52CE — Typical Wiring Schematic for Wall Thermostat Control Heat/Cool UnitsNOTES:1. Recommended for use

Page 44 - SOUND DATA (52P AND 52C)

49FRONT DESK SWITCH PANEL24-VTRANSFORMER(SEE NOTE 1)PTAC #1PTAC #2PTAC #NROOM 100 ROOM 101 ROOM NBWBWBWFIELD-SUPPLIEDLEGENDNOTES:1. To size transforme

Page 45 - WIRING DIAGRAMS (52P AND 52C)

5This section summarizes product features covered indetail in later sections of this manual: PRODUCT OVERVIEW (52P AND 52C)COPPER TUBEALUMINUMFIN COIL

Page 46

50WIRING DIAGRAMS (52P AND 52C) (cont)RYWGOCRYWGOCRYWGOCRYWGOCRYWGOCT’STATMASTERPTACUNIT 1UNIT 2UNIT 3Typical Wiring for Multiple PTAC Units Connected

Page 47

51PACKAGED TERMINALCOOLING UNIT WITHHEAT PUMP OR ELECTRIC HEATINGHVAC Guide SpecificationsSize Range: Cooling: 6,900 to 15,100 BtuhHeating: 6,000 to 1

Page 48

52axial flow design, with integrated slinger ring. Theindoor fan shall be a dynamically balanced, poly-mer, reverse curve blower wheel, to assure unif

Page 49

53P. Lateral Duct System (optional):The lateral duct system shall allow one system toheat or cool two adjacent rooms, with up to amaximum of 30% of th

Page 50

54TYPICAL WARRANTYCarrierPackaged TerminalAir Conditioner WarrantyFULL ONE-YEAR WARRANTY — During the first year after purchase, CARRIERwill, through

Page 51 - GUIDE SPECIFICATIONS

55Carrier CorporationIF YOUR AIR CONDITIONER DOES NOT WORK, FOLLOW THESE STEPS IN ORDER:1. CHECK THE THINGS YOU CAN DO YOURSELF. These include bei

Page 52 - GUIDE SPECIFICATIONS (cont)

56*Custom colors are also available.ACCESSORY FORM NUMBER PART NUMBER DESCRIPTIONWall Sleeves 52S-48SI WALL-SLEEVE-1PK Non-Insulated Polymer Wall Slee

Page 53

6The 52P and 52C models are a single-package,through-the-wall unit for heating and cooling hotelrooms, offices, apartments, condominiums, and resi-den

Page 54 - TYPICAL WARRANTY

7NO-RUST WEATHER LAST™WALL SLEEVE AND FRONTPANELThe indoor front panel and polymer wall sleeve usenonmetallic compounds that never rust or corrode, do

Page 55 - Carrier Corporation

8TWO-PIECE LIFETIME INDOOR FILTERNew two-piece removable filters easily slide in andout from the front of the PTAC unit and are inter-changeable. The

Page 56 - ACCESSORY LIST

9POWER CORD FOR 265-V UNITSA power cord is included for 265-v units. The powercord is 18 in. long (cord extends 15 in. from bottom offront panel) and,

Comments to this Manuals