Load spacers
Load on pallets
• Leave a free space of about :
- 6 to 8 cm between load and frontwall,
- 20 cm between the top of the load and the roof,
- between the floor and the load (gratings, pallets).
• Do not forget to close the doors.
OPTIONS FOR INSULATED BODIES
• Mobile partition
The mobile partition must be placed at a minimum distance from the evaporator of:
- 1300 mm for Supra 450
- 1600 mm for Supra 550 and 750
- 1700 mm for Supra 850 and 950
- 1000 mm from the auxiliary evaporator
• Ducting of evaporator air outlet
Ventilation ducts must never be covered.
• Before closing the doors, check your load once more and see that nobody is shut inside the box.
NOTE :
For stationary utilization, we recommend to place the
body in the shade.
I
MPORTANT
Never leave your unit more than a month without
running.
11