Load spacers
Load on pallets
Leave a free space of about :
- 6 to 8 cm between load and frontwall,
- 20 cm between the top of the load and the roof,
- between the floor and the load (gratings, pallets).
Do not forget to close the doors.
OPTIONS FOR INSULATED BODIES
Mobile partition
The mobile partition must be placed at a minimum distance from the evaporator of:
- 1300 mm for Supra 450
- 1600 mm for Supra 550 and 750
- 1700 mm for Supra 850 and 950
- 1000 mm from the auxiliary evaporator
Ducting of evaporator air outlet
Ventilation ducts must never be covered.
Before closing the doors, check your load once more and see that nobody is shut inside the box.
NOTE :
For stationary utilization, we recommend to place the
body in the shade.
I
MPORTANT
Never leave your unit more than a month without
running.