Physical data
* Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to
National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft above sea level.
Capacity in accordance with U.S. Government DOE test procedures.
Airflow shown is for bottom only return-air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each
return-air supply.
ICS Isolated Combustion System
Blower performance data
PSC-Permanent Split Capacitor
UNIT SIZE
045 070 090 110 135 155
08 12 08 12 14 16 12 16 22 16 22 20
OUTPUT CAPACITY BTUH*
(Nonweatherized ICS) †
all 58DLA; 58DLX
Upflow
35,000 36,000 53,000 54,000 71,000 71,000 89,000 89,000 89,000 107,000 107,000 125,000
58DLX Downflow/
Horizontal
34,000 34,000 51,000 51,000 68,000 68,000 85,000 85,000 85,000 102,000 102,000 119,000
INPUT BTUH*
all 58DLA; 58DLX
Upflow
44,000 44,000 56,000 66,000 88,000 88,000 110,000 110,000 110,000 132,000 132,000 154,000
58DLX Downflow/
Horizontal
42,000 42,000 63,000 63,000 84,000 84,000 105,000 105,000 105,000 126,000 126,000 147,000
SHIPPING WEIGHT (Lb)
104 107 111 115 127 140 135 146 152 149 163 170
CERTIFIED TEMP RISE RANGE (°F)
3060 2050 4070 3060 4070 3060 5080 4070 3060 5080 4070 4575
CERTIFIED EXT STATIC
PRESSURE
Heating
0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20 0.20 0.20 0.20 0.20
Cooling
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8 0.5 0.5 0.5
AIRFLOW CFM‡
Heating
920 1250 830 1195 1375 1505 1335 1515 1900 1525 1850 1790
Cooling
845 1160 900 1200 1385 1720 1355 1680 2220 1710 2110 2230
AFUE%*
Nonweatherized
ICS
80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
LIMIT CONTROL
SPST
HEATING BLOWER CONTROL
Solid-State Time Operation
BURNERS (Monoport)
223344555667
GAS CONNECTION SIZE
1/2-in. NPT
GAS VALVE (Redundant) Manufacturer
White-Rodgers
Minimum Inlet Pressure (In. wc)
4.5 (Natural Gas)
Maximum Inlet Pressure (In. wc)
13.6 (Natural Gas)
IGNITION DEVICE
Hot Surface
UNIT SIZE
045 070 090 110 135 155
08 12 08 12 14 16 12 16 20 16 20 20
DIRECT-DRIVE MOTOR Hp (PSC)
1/5 1/3 1/5 1/3 1/3 1/2 1/3 1/2 3/4 1/2 3/4 3/4
MOTOR FULL LOAD AMPS
2.9 5.2 2.9 5.2 5.2 7.9 5.2 7.9 11.1 7.9 11.1 11.1
RPM (Nominal) – Speeds
1075-3 1075-4 1075-3 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4
BLOWER WHEEL DIAMETER
WIDTHS (In.)
10 x 6 10 x 6 10 x 6 10 x 6 10 x 8 10 x 10 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11