Copyright 1998 Carrier Corporation Form No. 58PAV-8PD
Product
Data
58PAV
Energy-Efficient
Induced-Combustion
Upflow Furnace
Input Capacities:
45,000 thru 155,000 Btuh
80% AFUE At Budget Price
Carrier provides an 80 percent
Annual Fuel Utilization Efficiency
(AFUE) gas furnace for the budget
conscious consumer and builder. The
58PAV offers the same high quality
you demand and receive from Carrier.
The cabinet is constructed from a
specially selected galvanized steel.
There is also double protection for the
cabinet. First, a galvanized steel
substrate provides resistance to rusting.
Then the cabinet is constructed of
prepainted steel — the same high-
quality finish found on refrigerators
and dishwashers.
The 58PAV offers a hot surface
ignition system which provides a
superior and more reliable ignition
system than older spark relight systems.
The heat exchangers are
constructed of aluminized steel and
covered by a 20-year Limited
Warranty. They are Carrier’s patented
Super-S heat exchangers that improve
heat transfer and enable downsizing
of this furnace to only 40-in. tall.
A patented draft safeguard will stop
furnace operation if the vent system is
not operating properly.
To improve the sound level, we
have incorporated a soft mount
inducer assembly and a slow opening
gas valve.
The control board is the brain of
this induced-combustion gas furnace.
It offers a unique self-test feature
that checks all the major functions of
the furnace within 1 minute. The
control board also features a 3-amp
fuse that protects the transformer
and control board. Another feature
on the control board is an LED status
indicator light to ensure top furnace
performance.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Upflow Furnace

Copyright 1998 Carrier Corporation Form No. 58PAV-8PD ProductData 58PAVEnergy-EfficientInduced-CombustionUpflow Furnace Input Capacities:45,000 thru

Page 2 - Model number nomenclature

10Typical installationCONDENSINGUNITGAS-FIREDWATER HEATERELECTRONICAIR CLEANERAIRFLOWHUMIDIFIERA89242

Page 4 - Carrier accessories

Carrier Corporation • Indianapolis, IN 46231 1-98Manufacturer reserves the right to discontinue, or change at any time, specifications or designs with

Page 5 - Performance data

2 Model number nomenclature 58PAV 045Induced-CombustionUpflow FurnaceInput Capacity 045 — 44,000 Btuh 111 — 110,000 Btuh070 — 66,000 Btuh 135 — 132,0

Page 6

3 NOTE: The 58PAV Furnaces are for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed

Page 7 - Dimensions

4 Carrier accessories * * Factory-authorized and field installed. Gas conversion kits are A.G.A./C.G.A. recognized.† 16 and 20 sizes only. UNIT SIZE

Page 8 - TOP / PLENUM

5 Physical data * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft

Page 9 - Electrical data

6 AIR DELIVERY—CFM (With Filter)* * Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of th

Page 10 - Typical installation

7 Dimensions * A98025 DIMENSIONS (In.) UNIT SIZE A D E VENT CONN * (Dia)045-08 14-3/16 12-9/16 11-11/16 4 045-12 14-3/16 12-9/16 11-11/16 4 070-08

Page 11

8 A97621320325-101 REV. G (LIT)MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTIONThis forced air furnace isequipped for use withnatural gas at alti

Page 12 - SERVICE TRAINING

9 Typical wiring schematicElectrical data * Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent vo

Comments to this Manuals

No comments