Copyright 1998 Carrier Corporation Form No. 58YAV-2PD
Product
Data
58YAV
Energy-Efficient
Upflow Furnace
Sizes:
070 thru 155
Advanced Technology
for Energy-Efficient
Gas Furnaces
Carrier leads the industry with its
new 58YAV Induced-Draft Gas
Furnace. This furnace is built for
venting into many exterior tile-lined
masonry chimneys. It has the most
advanced manufacturing equipment,
processes, and technology available in
order to ensure top quality. Packed into
the cabinet are the industry’s foremost
dealer and homeowner features. The
58YAV Upflow Furnace is the newest
addition to Carrier’s list of product
leadership in the gas furnace industry.
These induced-combustion, gas-
fired furnaces offer not only low
installation costs, but fuel economy as
well — delivering an Annual Fuel
Utilization Efficiency (AFUE) rating
of 78.0 percent. The Carrier 58YAV
utilizes a hot surface, silicon carbide
ignition system to save energy and
increase reliability.
Our design uses the patented
S-shaped 4-pass heat exchanger, our
soft mount inducer assembly, and a
slow opening gas valve to improve
sound level. The heat exchanger is
constructed of aluminized steel and is
backed by a 20-year Limited Warranty.
The Carrier 58YAV Gas Furnace
will meet your home heating
requirements.
The superior attention to cabinet
detail is obvious. This Carrier furnace
features 1-piece, seamless, wrap-
around construction. There are no spot
welds on the exterior surfaces of the
furnace. There is also double
protection for the cabinet. First, a
galvanized steel substrate provides
resistance to rusting. Then the cabinet
is constructed of prepainted steel—the
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Upflow Furnace

Copyright 1998 Carrier Corporation Form No. 58YAV-2PD ProductData 58YAVEnergy-EfficientUpflow Furnace Sizes:070 thru 155 Advanced Technology for Ener

Page 2 - Model number nomenclature

2 Model number nomenclature 58YAV 070High-EfficiencyInduced-CombustionUpflow FurnaceInput Capacity 070 — 66,000 Btuh 136 — 132,000 Btuh091 — 88,000 B

Page 3

3 NOTES: 1. The 58YAV Furnaces are for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and A.G

Page 4 - Carrier accessories

4 Carrier accessories * * Factory-authorized and field installed. Gas conversion kits are A.G.A. and C.G.A. approved. UNIT SIZE 070-08 & 12 091-1

Page 5 - Performance data

5 Physical data * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft

Page 6 - 323653-101 REV. D (lit)

6 AIR DELIVERY—CFM (With Filter)* * Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of th

Page 7 - Dimensions

7 A98025 DIMENSIONS (In.) UNIT SIZE A D E VENT CONN * (Dia) 070-08 14-3/16 12-9/16 11-11/16 4 070-12 14-3/16 12-9/16 11-11/16 4 091-14 17-1/2 15-7/8

Page 8 - Electrical data

Electrical data * Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.† Permissible l