1
50TCQD
Single Package Rooftop
Heat Pump
with Puronr (R---410A) Refrigerant
Sizes 17 & 24
Installation Instructions
NOTE: Read the entire instruction manual before starting
the installation
TABLE OF CONTENTS
SAFETY CONSIDERATIONS 1....................
INSTALLATION 6...............................
Step 1 -- Plan for Unit Location 6..................
Step 2 -- Plan for Sequence of Unit Installation 7......
Step 3 -- Inspect Unit 7...........................
Step 4 -- Provide Unit Support 7...................
Step 5 -- Field Fabricate Ductwork 10...............
Step 6 -- Rig and Place Unit 10....................
Step 7 -- Duct Connection 11......................
Step 8 -- Install Outside Air Hood 12...............
Step 9 -- Install External Condensate Trap and Line 13.
Step 10 -- Make Electrical Connections 13...........
Step 11 -- Adjust Factory--Installed Options 42........
Step 12 -- Install Accessories 42...................
APPENDIX TYPICAL WIRING DIAGRAMS 43...
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical
shock or other conditions which may cause personal
injury or property damage. Consult a qualified installer,
service agency, or your distributor or branch for
information or assistance. The qualified installer or
agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual
instructions packaged with the kits or accessories when
installing.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloths for brazing operations and
have a fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions attached to
the unit. Consult local building codes and appropriate
national electrical codes (in USA, ANSI/NFPA70,
National Electrical Code (NEC); in Canada, CSA C22.1)
for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the
unit and in instructions or manuals, be alert to the
potential for personal injury.
Understand the signal words DANGER, WARNING,
CAUTION, and NOTE. These words are used with the
safety--alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or
death. WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify
unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to
highlight suggestions which will result in enhanced
installation, reliability, or operation.
Page view 0
1 2 ... 44

Summary of Contents

Page 1 - Installation Instructions

150TCQDSingle Package RooftopHeat Pumpwith Puronr (R---410A) RefrigerantSizes 17 & 24Installation InstructionsNOTE: Read the entire instruction ma

Page 2

50TCQD10A-B0.25” (6)B-C0.5” (12)A-C0.5” (12)MAXIMUM ALLOWABLEDIFFERENCE IN. (MM)ABCC09132Fig. 6 -- Unit Leveling TolerancesControl BoxAccess PanelFilt

Page 3

50TCQD11"B""C""A""914-1371"(36"-54")DETAIL ASEE DETAIL APLACE ALL SEAL STRIP IN PLACE BEFORE PLACING

Page 4

50TCQD12Step 8 — Install Outside Air HoodEconomizer and Two Position Hood Removal --Factory Option4. The hood is shipped in knock--down form and isloc

Page 5

50TCQD13Step 9 — Install External Condensate Trap andLineThe unit has one3/4-in. condensate drain connection onthe end of the condensate pan (see Fig.

Page 6 - INSTALLATION

50TCQD14!WARNINGFIRE HAZARDFailure to follow this warning could result inintermittent operation or performance satisfaction.Do not connect aluminum wi

Page 7 - Step 4 — Provide Unit Support

50TCQD15ConvenienceOutletElectricDisconnectSwitchControl BoxAccess PanelC09119Fig. 18 -- Convenience Outlet LocationInstalling Weatherproof Cover –A w

Page 8

50TCQD16if the GFCI receptacle does not trip as required. Press theRESET button to clear the tripped condition.Fuse on power type: The factory fuse is

Page 9

50TCQD17and then route the wire behind the corner post utilizing thefactory provided wire ties secured to the control box. Thiswill insure separation

Page 10 - Step 6 — Rig and Place Unit

50TCQD18Table 2 – Heater Model NumberBare Heater Model Number C R H E A T E R 2 7 9 A 0 0Heater Sales Package PNOIncludes:Bare HeaterCarton and packin

Page 11 - Step 7 — Duct Connection

50TCQD19PremierLinkt (Factory--Option) —C08199Fig. 27 -- PremierLink ControllerThe PremierLink controller (see Fig. 27) is compatiblewith Carrier Comf

Page 12 - Position

50TCQD2ELECTRICAL SHOCK HAZARDFailure to follow this warning could cause personalinjury or death.Before performing service or maintenance operationson

Page 13 - SIDE DRAIN

50TCQD20C10180Fig. 29 -- PremierLink Wiring Schematic

Page 14 - Units With Disconnect Option

50TCQD21Outdoor Air Temperature (OAT) Sensor — The OAT isfactory--mounted in the EconoMi$er2 (FIOP oraccessory). It is a nominal 10k ohm thermistor at

Page 15

50TCQD22Table 4 – Space Sensor ModeTB1 TERMINAL FIELD CONNECTION INPUT SIGNAL1 T 5 5 --- S E N / T 5 6 --- S E N Analog (10k thermistor)2 RMTOCC Discr

Page 16 - Corrections

50TCQD23Connect T--56 -- See Fig. 32 for T--56 internalconnections. Install a jumper between SEN and SETterminals as illustrated. Connect T--56 termin

Page 17 - Electric Heaters

50TCQD24Economizer controls —Outdoor Air Enthalpy Control (PNO 33CSENTHSW) --The enthalpy control (33CSENTHSW) is available as afield--installed acces

Page 18 - Table 2 – Heater Model Number

50TCQD25the supply air is blown directly onto the sensor or if thesupply air does not have a chance to mix with the room airbefore it is drawn into th

Page 19

50TCQD26input signal to PremierLink causes the filter status point toread “DIRTY”.Using Filter Timer Hours: Refer to Form 33CS--58SI forinstructions o

Page 20

50TCQD27enters another building, the shields must be connected tothe grounds at a lightning suppressor in each building (onepoint only).Connecting CCN

Page 21

50TCQD28RTU--MP control systemThe RTU--MP controller, see Fig. 46, provides expandedstand--alone operation of the HVAC system plusconnection and contr

Page 22 - Table 5 – Thermostat Mode

50TCQD29C10182Fig. 48 -- RTU--MP System Control Wiring Diagram

Page 23 - Cool Warm

50TCQD3C10135Fig. 1 -- Unit Dimensional Drawing – Size 17 Units

Page 24

50TCQD30Table 8 – RTU--MP Controller Inputs and OutputsPOINT NAMEBACnet OBJECTNAMETYPE OF I/OCONNECTION PINNUMBERSINPUTSSpace Temperature Sensor sptse

Page 25 - COVER REMOVED SIDE VIEW

50TCQD31The raceway provides the UL required clearance betweenhigh-- and low--voltage wiring. Pass the control wiresthrough the hole provided in the c

Page 26

50TCQD32in the space or in return duct, with and without LCDdisplay, and in combination with space temperaturesensors. Sensors use infrared technology

Page 27

50TCQD33Remote OccupancyThe remote occupancy accessory is a field--installedaccessory. This accessory overrides the unoccupied modeand puts the unit i

Page 28 - RTU--MP control system

50TCQD34Local AccessBACview6HandheldThe BACview6is a keypad/display interface used toconnect to the RTU--MP to access the control information,read sen

Page 29

50TCQD35Smoke DetectorsSmoke detectors are available as factory--installed optionson 50TCQD models. Smoke detectors may be specifiedfor Supply Air onl

Page 30

50TCQD36The sensor uses a process called differential sensing toprevent gradual environmental changes from triggeringfalse alarms. A rapid change in e

Page 31

50TCQD37Table 9 – Unit Wire/Fuse or HACR Breaker Sizing DataUNITN O M . V --- P h --- H zIFM TYPEELEC. HTR PE NO C.O. or UNPWR C.O.CRHEATER***A0 0Nom(

Page 32 - Fan Status

50TCQD38Table 9 — Unit Wire/Fuse or HACR Breaker Sizing Data (cont)UNITN O M . V --- P h --- H zIFM TYPEELEC. HTR PE w/ PWRD C.O.CRHEATER***A0 0Nom(kW

Page 33 - Power Exhaust (output)

50TCQD39Table 9 — Unit Wire/Fuse or HACR Breaker Sizing Data (cont)UNITN O M . V --- P h --- H zIFM TYPEELEC. HTR PE NO C.O. or UNPWR C.O.CRHEATER***A

Page 34 - Local Access

50TCQD4C10136Fig. 1 -- Unit Dimensional Drawing – Size 17 Unit (cont.)

Page 35 - Controller

50TCQD40Table 9 — Unit Wire/Fuse or HACR Breaker Sizing Data (cont)UNITN O M . V --- P h --- H zIFM TYPEELEC. HTR PE w/ PWRD C.O.CRHEATER***A00Nom(kW)

Page 36 - Sampling Tube

50TCQD41Legend and Notes for Table 9LEGEND:BRKR --- Circuit breakerCO --- Convenient outletDD --- Direct driveindoor fan motorDISC --- DisconnectFLA -

Page 37 - CRHEATER

50TCQD42Economizer 2 Position DamperUnit Without Economizer or2 Position DamperC10183Fig. 62 -- EconoMi$ert IV WiringStep 11 — Adjust Factory--Install

Page 38

50TCQD43APPENDIX — TYPICAL WIRING DIAGRAMSC10187Fig. 63 -- 50TCQ Typical Unit Wiring Diagram -- HP Control 460V, 575V 3 Phase

Page 39

50TCQD44C10186Fig. 64 -- 50TCQ Typical Unit Wiring Diagram -- Power 460V, 575V 3 PhaseCopyright 2011 Carrier Co rp. D 7310 W. Morris St. D Indianapoli

Page 40

50TCQD5C10137Fig. 2 -- Unit Dimensional Drawing – Size 24 Unit

Page 41 - AC = 226 v

50TCQD6C10138Fig. 2 -- Unit Dimensional Drawing – Size 24 Unit (cont.)INSTALLATIONJobsite SurveyComplete the following checks before installation.1. C

Page 42 - 2 Position Damper

50TCQD7Table 1 – Operating Weights50TCQD UNITS LB (KG) UNITS LB (KG)Component 17 24Base Unit 2035 923) 2200 (998)Economizer 245 (111) 245 (111)Powered

Page 43

50TCQD8C10139Fig. 4 -- Roof Curb Details – Size 17 Units

Page 44 - Catalog No: 50TCQ---08SI

50TCQD9C10140Fig. 5 -- Roof Curb Details – Size 24 Units