Single-package horizontally and verti-
cally mounted water source heat
pumps with electronic controls offer:
Two-stage unloading scroll
compressor
Variable speed blower motor
Exclusive double compressor
isolation for ultra-quiet operation
Available mute package for quieter
operation
Performance certified to AHRI/ISO
13256-1
Flexible and reliable multiple
protocol WSHP Open controller can
use BACnet
*
, Modbus
, N2, and
LonWorks** (with a separate card)
protocols for integrating energy
efficiency and precise unit control
Hot gas reheat (HGR) available for
dehumidification capability
Optional tin-plated copper tubing
and polymer coated aluminum fin
air coil available
Non-ozone depleting Puron
refrigerant (R-410A)
Features/Benefits
Carrier’s Aquazone two-stage
water source heat pump
(WSHP) with Puron
refrigerant (R-410A) is a high
quality, ultra-efficient solution
for all boiler/tower and
geothermal design
applications.
Operating efficiency
Carrier WSHPs are designed for quali-
ty and high performance over a life-
time of operation. Two-stage WSHP
models with Puron refrigerant offer
cooling EERs (Energy Efficiency Ra-
tios) to 37.0 and heating COPs (Coeffi-
ciency of Performance) to 6.5.
Aquazone™
50PTH, PTV024-070
Two-Stage Water Source Heat Pumps
with Puron
®
Refrigerant (R-410A)
2 to 6 Nominal Tons
Product
Data
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Features/Benefits

© Carrier Corporation 2015 Form 50PT-10PDSingle-package horizontally and verti-cally mounted water source heat pumps with electronic controls offer:•

Page 2 - Features/Benefits (cont)

10WSHP Open - ZS sensorsCarrier's ZS sensors are the preferred method of monitor-ing space temperature, humidity and CO2 levels when us-ing the W

Page 3

11Edge® Pro 7-day programmable thermostat is avail-able for connecting a unit directly to a wall mounted ther-mostat. The Edge Pro thermostat offers

Page 4

12AJWATER OUTWATER INLMNELECTRICALKNOCKOUT†BCHGERIGHT HAND RETURNEND DISCHARGE(5) HANGINGBRACKETSCONDENSATE DRAIN**ELECTRICALHEATKNOCKOUT(4) RETURNAIR

Page 5 - Model number nomenclature

13ELECTRICALKNOCKOUTS†ELECTRICHEATKNOCKOUT†SP'QR'EGBHCWATEROUTAJLWATERINFWATEROUTWATERINDKK'NMELECTRICHEAT KNOCKOUT†OCONDENSATEDRAIN**(

Page 6 - AHRI/ISO capacity ratings

14AAALEFT HAND RETURN - TOP VIEWEARIGHT HAND RETURN - TOP VIEWBBCCCADDDDCEØ 7/8A1:150PTH024-070 UNITS HANGING BRACKET SPECIFICATIONSNOTES:1. All dimen

Page 7 - Physical data

15SUPPLY AIRDUCT FLANGESRETURN AIR DUCT FLANGESWATER OUTSUPPLY AIRDUCT FLANGESRETURN AIRDUCT FLANGESCONDENSATE DRAIN**WATER INRIGHT HAND RETURNJKLAALE

Page 8 - Options and accessories

1650PTH 024-070 CORNER WEIGHTS* Front is control box end.LEGEND AND NOTES FOR PAGES 17-26LEGEND NOTES:1. Interpolation is permissible; extrapolation i

Page 9 - Field-installed accessories

1750PTH,PTV024650 CFM AT 0.34-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/wb)

Page 10 - ELECTRIC DUCT HEATERS

1850PTH,PTV024825 CFM AT 0.23-in. ESP — FULL LOADSee Legend and Notes on page 16.COOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PS

Page 11 - EDGE PRO THERMOSTAT

1950PTH,PTV036800 CFM AT 0.58-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/wb)

Page 12 - Dimensions

2All efficiencies stated are in accordance with standard conditions under ISO (In-ternational Organization for Standard-ization) Standard 13256-1:1998

Page 13 - Service Access to:

2050PTH,PTV0361,100 CFM AT 0.25-in. ESP — FULL LOADSee Legend and Notes on page 16.COOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop

Page 14 - Dimensions (cont)

2150PTH,PTV0481,300 CFM AT 0.27-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 15 - 50PTV024-070 UNITS

2250PTH,PTV0481,600 CFM AT 0.60-in. ESP — FULL LOADSee Legend and Notes on page 16.COOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop

Page 16

2350PTH,PTV0601,600 CFM AT 0.60-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 17 - Performance data

2450PTH,PTV0602,000 CFM AT 0.60-in. ESP — FULL LOADSee Legend and Notes on page 16.COOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop

Page 18 - Performance data (cont)

2550PTH,PTV0701,850 CFM AT 0.60-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 19 - Operation Not Recommended

2650PTH,PTV0702,350 CFM AT 0.60-in. ESP — FULL LOADSee Legend and Notes on page 16.COOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop

Page 20

27ANTIFREEZE CORRECTION TABLELEGENDCONSTANT TORQUE ECM MOTOR BLOWER PERFORMANCE DATALEGEND— — Operation Not RecommendedANTIFREEZETYPEANTIFREEZE %COOLI

Page 21

28ECM CONSTANT CFM MOTOR BLOWER PERFORMANCE DATALEGEND— — Operation Not Recommended50PTH, PTV UNITRATEDAIRFLOW(Cfm)FANSPEEDADJUSTMENTAIRFLOW (Cfm)Exte

Page 22

2950PTH,PTV SOUND DATAUNIT SIZE LOADOCTAVE BAND SOUND POWER LEVELS dB, re 10-12 WATTSCENTER FREQUENCY - HzA WEIGHTED OVERALL (dBA)63 125 250 500 1000

Page 23

3Hanging brackets — All horizontal units come standard with hanging bracket kits for suspending the unit from field-supplied hanger rods. These kits i

Page 24

3050PTH,PTV BLOWER MOTOR ELECTRICAL DATALEGEND50PTH,PTV UNITS WITH EH OPTION — CONSTANT TORQUE ECM MOTOR ELECTRICAL DATALEGEND50PTUNIT SIZERATED VOLT

Page 25

3150PTH,PTV UNITS WITH ELECTRIC HEAT OPTION — CONSTANT AIRFLOW ECM MOTOR ELECTRICAL DATALEGEND50PTUNIT SIZEEH RATED kW STAGEHEATER WATTS HEATER AMPSM

Page 26

32Aquazone™ water source heat pump products are availablein a flexible, efficient array of models, which can be used inall types of water loop, ground

Page 27 - ANTIFREEZE CORRECTION TABLE

33loop of pipe inserted into a hole. The hole is back-filled andgrouted after the pipe is inserted. The completed loop isconcealed below ground. The n

Page 28

34WATER QUALITY GUIDELINESLEGEND*Heat exchanger materials considered are copper, cupronickel, 304 SS(stainless steel), 316 SS, titanium.†Closed recirc

Page 29 - 50PTH,PTV SOUND DATA

35Acoustical designSound power levels represent the sound as it is producedby the source, the WSHP unit, with no regard to attenua-tion between the so

Page 30 - Electrical data

36Vertical unitsAll guidelines established for horizontal units also apply forvertical units. In addition, since vertical units tend to be in-stalled

Page 31

37The WSHP Open multi-protocol controller will control me-chanical cooling, heating, hot gas reheat and watersideeconomizer outputs based on its own s

Page 32 - Application data

38operate after heating or cooling is started while the fan offdelay defines the delay time (0 to 180 seconds; default 45)the fan will continue to ope

Page 33 - Water conditioning

39(proportional-integral) loop and heating stages capacity al-gorithm. They will be used to calculate the desired numberof stages needed to satisfy th

Page 34 - Application data (cont)

4unit is automatically deactivated and placed in a lockout condition. Thirty continuous seconds of overflow is rec-ognized as a fault by the sensor.Hi

Page 35 - Horizontal units

40Dehumidification with hot gas reheat (HGR)The WSHP Open controller will provide occupied and un-occupied dehumidification only on units that are equ

Page 36

41compressor output and if the compressor output is ener-gized, the compressor status input must detect the com-pressor operation.Filter status alarmT

Page 37 - Indoor fan

42Two-Stage Water Source Heat Pumps withPuron® Refrigerant (R-410A)HVAC Guide SpecificationsSize Range: 18,500 to 78,700 BtuhCooling Capacity14,400 to

Page 38 - Reverse cycle heating

43C. Access Panels:All units (horizontal and vertical) must have a mini-mum of three access panels for serviceability ofcompressor compartment. Units

Page 39 - Auxiliary heat

44Air-Conditioning, and Refrigeration) circuitbreakers. Unit controls shall be 24 volts.2. Solid-State Safety Circuit:All units shall have a solid-sta

Page 40

45b. Additional WSHP Open multiple protocolcontrol features shall include:1) Three-speed fan control. Controller shallautomatically, based upon space

Page 41

46cutouts. These devices must function inde-pendently of one another and are not accept-able if series connected in the control circuitwiring. A dis

Page 43

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 4

Page 44 - Guide specifications (cont)

5Aquazone™ Two-Stage Water Source HeatPump with Puron Refrigerant (R-410A)®024 – 2036 – 3048 – 4060 – 5070 – 6B – Right End Constant Torque E

Page 45

650PTH, 50PTV FULL LOAD APPLICATIONSLEGEND NOTES:1. A brine-to-air heat pump using a brine solution circulating through a subsurfacepiping loop functi

Page 46

7PHYSICAL DATA — 50PTH, PTV 024-070 UNITSLEGENDUNIT 50PTH, PTV 024 036 048 060 070COMPRESSOR ScrollREFRIGERANT CHARGE 50PTV (oz) 58 98 88 110 114REFRI

Page 47

8Factory-installed optionsCupronickel heat exchangers are available for highercorrosion protection for applications such as open tower,geothermal, etc

Page 48 - Replaces: 50PT-1APD

9COMPLETE C AND DELUXE D BOARD CAPABILITIES* WSHP Open installed with Complete C board.WSHP Open multi-protocol controller — Carrier'sWSHP Open c

Comments to this Manuals

No comments