38ESG, 38ETG, 38EZG
14, 13, 12 SEER Split-System
Air Conditioners, Sizes 018–060
Wiring Diagrams
Fig. 1—38ETG; 38EZG 018-048; 38ESG 024-048
208/230v, 1 Phase, 60 Hertz
A99329
CONNECTION DIAGRAM
SCHEMATIC DIAGRAM (LADDER FORM)
-NOTES-
-LEGEND-
(NOTE #9)
BLK
or
RED
BLK
BLK
or RED
*CHS
*CH
208/230 1Ø
POWER
SUPPLY
L1
L2
EQUIP
GND
(NOTE #14)
BLU
11 21
23 23
CONT
BLK
BLK
BLK
BLU
BLU
BLU
YEL
YEL
YEL
YEL
YEL
BRN
BRN
BRN
BLK
OFM
(NOTE #8)
COMP
CAP
C
S
R
C
H
F
*SC
*ST
*SR
1
2
5
BLU/PNK
BLU/PNK YEL/PNK
YEL/PNK
BLK
BLK
*HPS
*DTS *LPS
*CTD
LOGIC
VIO
T2
T1
T3
BRN
BLK
BLKBLU
BLU
*LLS
EXTERNAL
POWER
SUPPLY
24V
(NOTE #3)
INDOOR THERMOSTAT (NOTE #6) INDOOR BLOWER MOTOR
C
R
Y
R
G
*CH
*CHS
COMP
C
S
R
L1
L2
EQUIP
GND
11 21
1
2
5
*SR
CONT
*SC
*ST
CONT
23 23
CAP
C
H
F
OFM
(NOTE #14)
CONT
LOGIC
T2
T1
T3
*HPS
*DTS *LPS
*CTD
*LLS
INDOOR
THERMOSTAT)
EXTERNAL POWER SUPPLY 24V
Y
R
G
RC
IFR
CONT
CAP
*CH
*CHS
COMP
*CTD
*DTS
*HPS
IFR
*LLS
*LPS
OFM
*SC
*SR
*ST
FACTORY POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
COMPONENT CONNECTION
FIELD SPLICE
JUNCTION
CONTACTOR
CAPACITOR (DUAL RUN)
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
COMPRESSOR
COMPRESSOR TIME DELAY
DISCHARGE TEMP. SWITCH
HIGH PRESSURE SWITCH
INDOOR FAN RELAY
LIQ. LINE SOLENOID VALVE
LOW PRESSURE SWITCH
OUTDOOR FAN MOTOR
START CAPACITOR
START RELAY
START THERMISTOR
*MAY BE FACTORY OR FIELD INSTALLED.
1. Symbols are electrical representation only.
2. Compressor and fan motor furnished with
inherent thermal protection.
3. To be wired in accordance with National
Electric N.E.C. and local codes.
4. N.E.C. class 2, 24 V circuit, min. 40 VA
required, 60 VA on units installed with LLS.
5. Use copper conductors only. Use conductors
suitable for at least 75°C (167°F).
6. Connection for typical cooling only thermostat.
For other arrangements see installation
instructions.
7. If indoor section has a transformer with a
grounded secondary, connect the grounded
side to the BRN lead.
8. When start relay and start capacitor are
installed, start thermistor is not used.
9. CH not used on all units.
10. If any of the original wire, as supplied, must
be replaced, use the same or equivalent wire.
11. Check all electrical connections inside control
box for tightness.
12. Do not attempt to operate unit until service
valves have been opened.
13. Do not rapid cycle compressor. Compressor
must be off 3 minutes to allow pressures to
equalize between high and low side before
starting.
14. Wire not present if HPS, LPS, DTS or CTD
are used.
1.Compressor damage may
occur if system is over
charged.
2.This unit is factory charged
with R-410A in accordance
with the amount shown on the
rating plate. The charge is
adequate for most systems
using matched coils and tubing
not over 15 feet long. Check
refrigerant charge for
maximum efficiency. See
Product Data Literature for
required Indoor Air Flow Rates
and for use of line lengths over
15 feet.
3.Relieve pressure and recover
all refrigerant before system
repair or final unit disposal.
Use all service ports and open
all flow-control devices,
including solenoid valves.
4.Never vent refrigerant to
atmosphere. Use approved
recovery equipment.
CAUTION
!
325655-101 REV. A
Visit www.carrier.com
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 2a 3a
PC 101 Catalog No. 533-80091 Printed in U.S.A. Form 38ESG-1W Pg 1 1-03 Replaces: New