58UVB PERFOR MANCEt
t
96
95% AFUE UPFLOW ONLY V A RI ABLE---SPEED
CONDENSING GAS FURNACE
Series 120, Input R at es 60,000 t hr u 120,000 Bt uh
Product Data
A05097
Comfort Heatt
t
TECHNOLOGY,
THE ULTIMATE IN HEATING
COMFORT...
The Carrier Performancet 96 with Comfort Heatt technology
achieves the optimum combination of comfort and efficiency.
The Performancet 96 achieves up to 95 percent Annual Fuel
Utilization Efficiency (AFUE). Ef ficient performance is enhanced
through the variable-- speed design. To maintain ideal comfort,
Comfort Heat technology automatically adjusts the heating level,
maximizing the use of low heating levels that produce near silent
furnace operation while meeting the exact heating needs. This
unit is designed to keep the indoor temperature within 1 degree of
the thermostat set point. Because it operates in low heat most of
the time, the Performance 96 uses up to 80% less power than
single--capacity furnaces.
In addition to providing ultimate comfort, the Performance 96 has
a sealed combustion system. This system brings combustion air to
the furnace and vents flue gases outside the furnace in a safe
manner . Because it is sealed, operational noise is minimal. A
sealed combustion system also means fewer cold drafts and less
air infiltration.
The Performance 96 is available in 5 heat/airflow combinations.
The unit has an upflow only design. The Performance 96 can be
installed as a Direct vent/2-- pipe only. The Performance 96 is not
approved for installation in mobile homes, recreational vehicles,
or outdoor use.
The variable speed makes the Performance 96 ideal for use with
split--system cooling, including 2 -- stage units. A Carrier
electronic air cleaner, humidifier, Thermidistatt, comfort
ventilator, and Comfort Zonet II will provide year--round
comfort and efficiency.
Designed for durability, comfort, and reliability, the Performance
96 is the ultimate in versatile, ef ficient comfort.
PERFORMANCE 96 FEATURES/
BENEFITS
IdealHumidity Technology
The IdealHumidity system actively controls both temperature and
humidity in your home to provide the best comfort all year long.
Other systems depend on heating or cooling to manage the
moisture in the air. But IdealHumidity gives you the right amount
of humidity, day and night, even in mild weather. No other
manufacturer can do this! IdealHumidity saves energy, too. By
keeping humidity under control, you can set your thermostat to
stay comfortable and save energy—up to 20% off your cooling
costs!
Comfort Heat Technology
On the coldest days of the year, the Performance 96 Furnace has
the capacity to heat your home. On moderate days when less heat
is required, this furnace will regulate itself to a lower
capacity—providing a comfortable home and minimizing
operating costs.
The patented algorithm adjusts the low--heat operating time to
match the indoor conditions.
Reliable Heat E xchanger Design
The primary heat exchanger is made of aluminized steel for
corrosion resistance. The patented Serpentufft condensing heat
exchanger cells are laminated with polypropylene for greater
resistance to corrosion and epoxy coated externally to prevent
oxidation. This breakthrough in heating technology helps extend
the life of the furnace for years of dependable performance. The
heat exchanger is positioned in the furnace to extract additional
heat.
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Product Data

158UVB PERFOR MANCEtt9695% AFUE UPFLOW ONLY V A RI ABLE---SPEEDCONDENSING GAS FURNACESeries 120, Input R at es 60,000 t hr u 120,000 Bt uhProduct Data

Page 2

10AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)*Unit Size Operating ModeCFM AirflowSettingExternal StaticPressure Range*External Static Pressure (ES

Page 3

11CONCENTRIC VENT (DIRECT VENT/2--PIPE ONLY) (ALL MODEL SIZES)C IN. DIAB IN. DIA PVCVENT/EXHAUST13/16B IN. DIA PVCINTAKE/COMBUSTION AIRDEFA11/2A97110D

Page 4 - CARRIER ACCESSORIES

12DIMENSIONSNOTES:1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,see flex duct manufacturerís recommendations fo

Page 5 - CARRIER ACCESSORIES CONTINUED

13TYPICAL WIRING SCHEMATIC115-VOLT FIELD-SUPPLIEDFUSEDDISCONNECT JUNCTIONBOX CONTROLBOX24-VOLTTERMINALBLOCK THREE-WIREHEATING-ONLY FIVEWIRE N

Page 6

14MAXIMUM ALLOWABLE PIPE LENGTH (FT / M)D i r e c t V e n t ( 2 --- P i p e O n l y )NUMBER OF 90_ELBOWSUNIT SIZE(BTUH)ALTITUDETerminationTypePipe Dia

Page 7 - Inducer Assembly

15MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) (CONTINUED)ALTITUDEUNIT SIZE(BTUH)Direct Vent (2--Pipe Only)NUMBER OF 90_ELBOWSTerminationTypePipe Dia(IN.)*1

Page 8 - Always Ask For

16MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH -- FT (M)WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*UNIT SIZEWINTER DESIGNMAXIMUM PIPEDIAMETERI

Page 9 - PERFORMANCE DATA

17TYPICAL INSTALLATIONSCOMBUSTION AIR PIPEA/C COILOUTDOOR UNITVENT PIPEHUMIDIFIERGAS-FIREDWATER HEATERELECTRONICAIR CLEANERAIRFLOWFRONT OFFURNACEA0651

Page 10

18GUIDE SPECIFICATIONSGENERALSystem DescriptionFurnish a ______________________ (upflow) gas--firedcondensing furnace for use with natural gas or prop

Page 11 - CONDENSATE TRAP

2Power HeattIgniterCarrier’s unique SiN igniter is not only physically robust but it isalso electrically robust. It is capable of running at line volt

Page 12 - ELECTRICAL DATA

3126161517810651131424379111819A02287NOTES:1. The 58UVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a

Page 13 - TYPICAL WIRING SCHEMATIC

4MODEL NUMBER NOMENCLATURE58UVB14--- --- ---100Deluxe Upflow onlyV a r i a b l e --- S p e e d D i r e c t --- V e n t ( 2 --- P i p e ) a n dCondensi

Page 14 - *See notes on next page

5CARRIER ACCESSORIES CONTINUEDDESCRIPTION PART NO.UNIT SIZE060---14 080--- 14 080--- 20 100---20 120--- 20N a t u r a l --- To --- P r o p a n e G a s

Page 15 - Direct Vent (2--Pipe Only)

6THERMOSTAT AND ZONI NG CONTROL OPTIONSNON---PROGRAMMABLE THERMOSTAT SELECTIONT C --- N A C o r T P --- N A CFor use with 1 speed Air Conditioner ---

Page 16 - CLEARANCE TO COMBUSTIBLES

7XA92505Heat ExchangersControl CenterA02286Inducer AssemblyACRDJ AIR CONDITIONING RELAY DISABLE JUMPERHUMIDIFIER TERMINAL (24-VAC 0.5 AMP MAX. CONTIN

Page 17 - TYPICAL INSTALLATIONS

8®A97152Electronic or MechanicalAir CleanerCleans the air of smoke,dirt, and many pollenscommonly found. Savesdecorating and cleaningexpenses by keepi

Page 18 - GUIDE SPECIFICATIONS

9PHYSI CAL DATADESCRIPTIONUNIT SIZE060---14 080---14 080---20 100---20 120---20Direct--- Drive Motor Hp (ECM) 1/2 1/2 1 1 1Motor Full Load Amps 7.7 7.

Comments to this Manuals