Wiring Diagrams
Units Produced After December 1998
DIAGRAM INDEX
38AQS Field Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fig. 1-4
Motormaster® Control Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fig. 5-12
LEGEND (Fig. 1 through 12)
NOTES
1. Compressor and fan motor(s) thermally protected. Three-phase
motors are protected against primary single-phasing conditions.
2. If any of the original wire furnished must be replaced, it must be
replaced with type 90 C wire or its equivalent.
3. Terminal block 2 (TB2) is for field external control connections,
Class 2 wiring. Supply voltage at TB2 is 24 vac. Maximum
power available at TB2 is 31.5 va.
4. Field-supplied component ratings: IFC sealed coil rating
(24 vac) 12 va max.
5. Use thermostat HH07AT172 with subbase HH93AZ177.
6. Use copper, copper-clad aluminum, or aluminum conductors for
field power supply only.
7. Insulate unused lead when changing tap for 208 volt use.
8. The CB must-trip amps are equal to or less than 140% FLA.
9. Set thermostat heat anticipator(s) for first stage .79; for second
stage .63.
10. The CLO locks out the compressor to prevent short cycling on
compressor overload and safety devices. Before replacing CLO,
check these devices.
11. Remove jumper between RC and RH.
12. Defrost cycle time is factory set at 30 min.
UNIT LABEL DIAGRAM
Unit
38AQS
V-Ph -Hz
Label Diagram
No.
Schematic
Figure
Component Arrangement
Figure
012,016
208/230-3-60
38AK502714 1 2230-5-50
400-3-50
460-3-60
38AK502724 3 4
575-3-60
38AQS012,016
Air-Cooled Split System Heat Pump
50/60 Hz
AHA —
Adjustable Heat Anticipator
C—
Contactor
CAP —
Capacitor
CB —
Circuit Breaker
CC —
Cooling Compensator
CH —
Crankcase Heater
CLO —
Compressor Lockout
COMP —
Compressor
CR —
Control Relay
CT —
Current Transformer
CTD —
Compressor Time Delay
DB —
Defrost Board
DFB —
Defrost Board
DFR —
Defrost Relay
DFT —
Defrost Thermostat
EQUIP —
Equipment
FCPS —
Fan Cycling Pressurestat
FLA —
Full Load Amps
FU —
Fuse
GND —
Ground
HPS —
High-Pressure Switch
HR —
Heater Relay
IFC —
Indoor-Fan Contactor
IP —
Internal Protector
L—
Light
LCS —
Loss-of-Charge Switch
LLS —
Liquid Line Solenoid
LOR —
Lockout Relay
NDR —
No-Dump Relay
NEC —
National Electrical Code
OFC —
Outdoor-Fan Contactor
OFM —
Outdoor-Fan Motor
OFR —
Outdoor-Fan Relay
OPS —
Oil Pressure Switch
PCB —
Printed Circuit Board
QT —
Quadruple Terminal
R—
Isolation Relay
RC —
Cooling Connection (Thermostat)
RH —
Heating Connection (Thermostat)
RVR —
Reversing Valve Relay
RVS —
Reversing Valve Solenoid
SOL —
Solenoid
TB —
Terminal Block Terminal
TC —
Thermostat — Cooling
TH —
Thermostat — Heating
TRAN —
Transformer
U—
Unloader
UR —
Unloader Relay
Terminal (PCB, Field)
Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice (Factory)
Splice (Field)
Splice (Marked Wire)
Wiring Factory
Wiring Field Control
Wiring Field Power
Option or Accessory
PCB Run