Table 5--Superheat Charging
EVAPORATOR ENTERING AiR TEMPERATURE ('F WB)
50 52 54 56 58 60 62 64 66 68 70 72 74 76
9 12 14 17 20 23 26 29 32 35 37 40 42 45
7 10 t2 16 18 21 24 27 30 35 35 38 40 43
6 10 13 16 19 21 24 27 30 33 36 38 41
-- 7 10 13 16 19 21 24 27 30 33 36 39
-- -- 6 9 12 15 10 21 24 26 31 34 37
-- -- -- 5 8 12 15 16 21 25 26 3! 35
..... 8 11 15 19 22 26 30 33
..... 5 9 13 16 20 24 27 31
...... 6 10 14 18 22 25 29
........ 8 12 15 20 23 27
....... 5 9 13 17 22 26
....... 6 11 15 20 25
......... 6 14 t8 23
be weighedin.
-- Where a dash a )ears, do not attempt to charge system under these conditions or refrigerant slugging may OCCur. Charge must
NOTE: Superheat °F is at low-side sewice port.
Table 6---Required Suction-Line Tube Temperature (°F)
SUPERHEAT SUCTION PRESSURE AT SERVICE PORT (PSlG)
61.5
35
37
39
41
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
64.2
37
39
41
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
67,1
39
41
43
45
47
49
51
63
55
57
59
61
63
65
67
69
71
73
75
77
79
70.0
41
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
73.0
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
76.0
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
86
TEMP
(°F)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
4O
79.2
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
85
87
82.4
49
51
53
55
57
59
6f
63
65
67
69
71
73
75
77
79
81
83
85
87
89
85.7
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
85
87
89
91
10. If outdoor air temperature or pressure at suction valve
changes, charge to new suction line temperature indicated on
chart.
HEATING CHECK CHART PROCEDURE
To check system operation during heating cycle, refer to the
Heating Check Chart on outd(x3r unit. This chart indicates whether
a correct relationship exists between system operating pressure and
air temperature entering indoor and outdoor units. If pressure and
temperature do not match on chart, system refrigerant charge may
not be correct. Do not use chart to adjust refrigerant charge.
NOTE: When charging is necessary during heating season,
charge must be weighed in accordance with unit rating plate + 0.6
oz/ft of 3/8-in. liquid line ab_we or below 15 ft respectively.
EXAMPLE:
To calculate additional charge required I_,r a 25-ft line set:
25 ft - 15 ft = 10 ft X 0.6 oz/ft = 6 oz of additional charge
---)'Step 14_Final Checks
IMPORTANT: Before leaving job, be sure to do the following:
I. Securely fasten all panels and covers.
2. Tighten service valve stem caps to 1/12-turn past finger tight.
3. Leave User's Manual with owner. Explain system operation
and periodic maintenance requirements outlined in manual.
4. Fill out Dealer Installation Checklist and place in customer
file.
CARE AND MAINTENANCE
For continuing high performance and to minimize possible equip-
ment failure, periodic maintenance must be pertbrmed on this
equipment.
Frequency of maintenance may vary depending upon geo_m'aphic
areas, such as coastal applications.
Copyright 1998 CARRIER Corp. - 7310 W. Morris St. Indianapolis, IN 46231 38ykc2si
Manufacturer reserves the dght to discontinue, or change at any time, specifications or designs without notice and without Incurring obligatlorls.
PC 101 Catalog No. 563 718 Printed in U.S.A Form 38YKC_2SI Pg 12 11-96 Replaces: 38YKC-1SI
Page view 11
1 2 ... 7 8 9 10 11 12

Comments to this Manuals

No comments