Single-package horizontally and verti-
cally mounted water source heat
pumps (WSHPs) with electronic con-
trols offer:
High-efficiency design
Operating temperature range of
20 F to 110 F
Thermostatic expansion valve
(TXV) provides efficient and reliable
refrigerant flow
Available mute package for quiet
operation
Three service panels on
compressor section for easy
maintenance
Spring-mounted compressors for
quiet operation
Ease of installation with factory-
mounted flow regulators and control
valves
Features/Benefits
Aquazone high-efficiency
WSHPs are a flexible
alternative for all boiler/tower
and geothermal design
applications.
Operating efficiency
The horizontal and vertical WSHPs are
designed for quality and high perfor-
mance over a lifetime of operation.
Aquazone high efficiency units offer
cooling EERs (Energy Efficiency Ra-
tios) to 13.3 and heating COPs (Coeffi-
cients of Performance) to 4.6. Efficien-
cies stated are in accordance with stan-
dard conditions under ISO
(International Organization for Stan-
dardization) Standard 13256-1 and
provide among the highest ratings in
the industry, exceeding ASHRAE
(American Society of Heating, Refrig-
erant and Air Conditioning Engineers)
90.1 Energy Standards.
AQUAZONE™
50RHR006-060,50RVR009-060
High-Efficiency
Water Source
Heat Pumps
Horizontal —
1
/
2
to 5 Nominal Tons
Vertical
3
/
4
to 5 Nominal Tons
Product
Data
TM
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - Features/Benefits

Copyright 2008 Carrier Corporation Form 50HR,RVR-1PDSingle-package horizontally and verti-cally mounted water source heat pumps (WSHPs) with electroni

Page 2 - Table of contents

10DimensionsNOTES:1. Condensate is 3/4-in. FPT copper.2. Horizontal unit shipped with filter bracket only. This bracket should be removed for return d

Page 3 - Maximum control flexibility

11NOTES:1. Condensate is 3/4-in. FPT and is switchable from side to front.2. Vertical unit shipped with filter bracket only extending from unit 2.5 in

Page 4 - Model number nomenclature

12I Determine the actual cooling and heatingloads at the desired dry bulb (db) and wetbulb (wb) conditions.Assume cooling load at desired dry bulb 80

Page 5 - ARI/ISO capacity ratings

13VII ARI/ISO/ASHRAE 13256-1 ConversionPerformance standard ARI/ISO/ASHRAE 13256-1became effective on January 1, 2000 and replacedthe existing ARI Sta

Page 6 - Physical data

1450RHR006 UNIT PERFORMANCE200 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering ai

Page 7 - Options and accessories

1550RHR,RVR009 UNIT PERFORMANCE300 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enterin

Page 8 - Field-installed accessories

1650RHR,RVR012 UNIT PERFORMANCE375 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enter

Page 9 - CARRIER AQUAZONE™ THERMOSTATS

1750RHR,RVR015 UNIT PERFORMANCE500 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enter

Page 10 - 50RHR006-060 UNITS

1850RHR,RVR019 UNIT PERFORMANCE600 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enter

Page 11 - 50RVR009-060 UNITS

1950RHR,RVR024 UNIT PERFORMANCE800 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enter

Page 12 - (with 50RHR024 example)

2High quality construction and testingAll units are manufactured to meet ex-tensive quality control protocol from start to finish through an automated

Page 13

2050RHR,RVR030 UNIT PERFORMANCE1000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enter

Page 14 - Performance data

2150RHR,RVR036 UNIT PERFORMANCE1200 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enteri

Page 15 - 50RHR,RVR009 UNIT PERFORMANCE

2250RHR,RVR042 UNIT PERFORMANCE1400 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enteri

Page 16 - Performance data (cont)

2350RHR,RVR048 UNIT PERFORMANCE1600 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enter

Page 17 - 50RHR,RVR015 UNIT PERFORMANCE

2450RHR,RVR060 UNIT PERFORMANCE2000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All enterin

Page 18

25CORRECTION FACTORS — NOMINAL CFM — 50RHR,RVR UNITSLEGENDNOTE: Nominal airflow is 400 cfm.CORRECTION FACTORS — ENTERING AIR — 50RHR,RVR UNITSLEGEND *

Page 19 - 50RHR,RVR024 UNIT PERFORMANCE

2650RHR,RVR BLOWER PERFORMANCELEGEND*Size 006 available in 50RHR units only.NOTES:1. Units factory shipped on medium speed. Other speeds requirefield

Page 20

2750RHR,RVR UNITSRADIATED SOUND POWER DATANOTES:1. All sound power level performance is expressed in dB with reference to1 picoWatt.2. Data based on

Page 21 - 50RHR,RVR036 UNIT PERFORMANCE

2850RHR,RVR UNITS WITH MUTE PACKAGE OPTIONRADIATED SOUND POWER DATANOTES:1. All sound power level performance is expressed in dB with refer-ence to 1

Page 22

2950RHR,RVR UNITS WITH MUTE PACKAGE OPTION (cont)RADIATED SOUND POWER DATA (cont)NOTES:1. All sound power level performance is expressed in dB with r

Page 23 - 50RHR,RVR048 UNIT PERFORMANCE

3 All components are carefully de-signed and selected for endurance, durability, and carefree day-to-dayoperation. The Aquazone™ unit is shipped t

Page 24

3050RHR,RVR ELECTRICAL DATALEGEND*Size 006 is available in 50RHR units only.50RHR,RVRUNITVOLTS-PHASE60 HzVOLTAGEMIN/MAXCOMPRESSOR FANMOTORFLATOTALUNIT

Page 25

31Typical piping and wiringThermostatWiringWater InWater OutBall Valve with optional integral P/T plug (typical for supply and return piping)Unit Powe

Page 26

32Typical wiring schematicsAquazoneThermostatPMStg 1/Stg 2See Note 9*Optional wiring.AL — Alarm Relay ContactsBM — Blower MotorBMC — Blower Motor Capa

Page 27 - 50RHR,RVR UNITS

33AquazoneThermostatPMAL — Alarm Relay ContactsBM — Blower MotorBMC — Blower Motor CapacitorCB — Circuit BreakerCC — Compressor ContactorCO — Sensor,

Page 28

34Typical control wiringYWOGRCAL1AL2ACRCMP1FANPWRHS1/EXH/RVSPREMIERLINKCRCOMPLETECCONTROLJ4J6J5J8J1PWRSPSALWCMPSAFETTTY1GRCAL1CMP1FANPWRPREMIERLINKDEL

Page 29

35Aquazone™ water source heat pump products are availablein a flexible, efficient array of models, which can be used inall types of water loop, ground

Page 30 - Electrical data

36Vertical ground loop — This system is used in verticalborehole applications. This design is well suited for retrofitapplications when space is limit

Page 31 - UNIT HANGER ISOLATION DETAIL

37by noise criteria (NC) curves. Noise criteria curve levels rep-resent a peak over a full spectrum of frequencies. A highvalue in a low frequency ban

Page 32 - Typical wiring schematics

38air grilles. Face the elbow or boot away from the near-est adjacent WSHP unit to prevent additive noise.21. Do not hang suspended ceiling from the d

Page 33 - Thermostat

39Packaged High Efficiency Water Source Heat PumpsHVAC Guide SpecificationsSize Range: 5,400 to 59,000 BtuhCooling Capacity7,400 to 68,000 BtuhHeating

Page 34 - Typical control wiring

4PremierLink™ controller adds reliability, efficiency, and simplificationThe PremierLink direct digital control-ler can be ordered as a factory-inst

Page 35 - Application data

404. The fan motor shall be isolated from the fanhousing by torsionally flexible isolation grom-mets. The fan and motor assembly must becapable of ove

Page 36 - Application data (cont)

41b. All water connections and electrical knock-outs must be in the compressor compart-ment corner post as to not interfere with theserviceability of

Page 37 - Horizontal units

426. PremierLink™ Controller:This optional control will function with CCNand ComfortVIEW™ software. It shall also becompatible with ComfortLink™ contr

Page 39 - Guide specifications

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 4

Page 40 - Guide specifications (cont)

550RHR,50RVR UNIT WATER LOOP APPLICATIONSLEGENDNOTES:1. A water-to-air heat pump using water or brine circulating in a common pipingloop functioning a

Page 41

6PHYSICAL DATA — AQUAZONE™ 50RHR,RVR006-060 UNITSLEGENDPSC — Permanent Split Capacitor*Size 006 available in 50RHR unit only.NOTES:1. All units have s

Page 42

7Factory-installed optionsCupronickel heat exchangers are available for highercorrosion protection for applications such as open tower,geothermal, etc

Page 43

8Field-installed accessoriesCarrier’s line of Aquazone™ thermostats are bothattractive and multi-functional, accommodating stand-alone water source h

Page 44 - Ta b 6 a

9COOLHEATAUTOR5-DAY PROGRAMMABLE/NON-PROGRAMMABLEAUTOPmCOOLHEATCarrier®CARRIER AQUAZONE™ THERMOSTATS7-DAY PROGRAMMABLE/LIGHT-ACTIVATEDPROGRAMMABLE7-DA