Copyright 2001 Carrier Corporation Form 50R-1PDCarrier’s Aquazone™ single-packaged horizontal and vertical water source heat pumps are available in st
1050RHS,50RVS WATER LOOP APPLICATIONSLEGENDNOTES:1. A water-to-air heat pump using water or brine circulating in a common pipingloop functioning as a
11DimensionsFrontKMBlowerOutletJLCAP=Control Access PanelCSP=Compressor Service PanelBSP=Blower Service PanelASP=Alternate Service PanelRight ReturnF
12Dimensions (cont)FrontKMBlowerOutletJLCAP=Control Access PanelCSP=Compressor Service PanelBSP=Blower Service PanelASP=Alternate Service PanelRight
13Access PanelsL Configuration - Top View-Left ReturnR Configuration - Top View-Right ReturnROPIsometricViewL Configuration - Left Return Left View- A
14Dimensions (cont)NOTES:1. Condensate is 3/4-in. FPT and is switchable from side to front.2. Vertical unit shipped with filter bracket only extending
15I Determine the actual cooling and heatingloads at the desired dry bulb and wet bulbconditions.Assume cooling load at desired dry bulb 80 F andwet b
16VII ARI/ISO/ASHRAE 13256-1 ConversionPerformance standard ARI/ISO/ASHRAE 13256-1became effective on January 1, 2000 and replacedthe existing ARI Sta
1750RHR006200 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions are 8
1850RHR,RVR009300 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
1950RHR,RVR012375 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
2Operating efficiencyCarrier horizontal and vertical water source heat pumps are designed for quality and high performance over a lifetime of operatio
2050RHR,RVR015500 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
2150RHR,RVR019600 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
2250RHR,RVR024800 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
2350RHR,RVR0301000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
2450RHR,RVR0361200 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
2550RHR,RVS0421400 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
2650RHR,RVS0481600 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
2750RHR,RVS0602000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
2850RHS,RVS015500 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
2950RHS,RVS018600 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
3Simple maintenance andserviceabilityWhen regular maintenance or a service call is scheduled, the WSHP (Water Source Heat Pump) units require little t
3050RHS,RVS024800 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
3150RHS,RVS0301000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
3250RHS,RVS0361150 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions a
3350RHS,RVS0421400 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
3450RHS,RVS0481600 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
3550RHS,RVS0602000 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
3650RHS,RVS0702300 CFM NOMINAL AIRFLOW LEGEND NOTES:1. Interpolation is permissible, extrapolation is not.2. All entering air conditions
37CORRECTION FACTORS — NOMINAL CFM — 50RHR,RVR UNITSNOTE: 400 cfm is nominal airflow.CORRECTION FACTORS — ENTERING AIR — 50RHR,RVR UNITS*Sensible cap
38CORRECTION FACTORS — NOMINAL CFM — 50RHS,RVS UNITSNOTE: 400 cfm is nominal airflow.CORRECTION FACTORS — ENTERING AIR — 50RHS,RVS UNITS*Sensible capa
3950RHR,RVR BLOWER PERFORMANCELEGEND*Size 006 available in 50RHR units only.NOTES:1. Units factory shipped on medium speed. Other speeds requirefield
4Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3Model Number Nomenclature . . . . . . . . .
4050RHS,RVS BLOWER PERFORMANCELEGEND— — Not RecommendedNOTES:1. Includes allowance for wet coil and clean factory-installed filter.2. Factory settings
4150RHR,RVR UNITSRADIATED SOUND POWER DATANOTES:1. Data based on sound measurements made in a reverberant room on represen-tative units from each cabi
4250RHR,RVR UNITS WITH MUTE PACKAGE OPTIONRADIATED SOUND POWER DATANOTES:1. Data based on sound measurements made in a reverberant room onrepresentati
4350RHR,RVR UNITS WITH MUTE PACKAGE OPTION (cont)RADIATED SOUND POWER DATA (cont)NOTES:1. Data based on sound measurements made in a reverberant room
4450RHS,RVS UNITSRADIATED SOUND POWER DATANOTES:1. Data based on sound measurements made in a reverberant room onrepresentative units from each cabine
4550RHS,RVS UNITS WITH MUTE PACKAGE OPTIONRADIATED SOUND POWER DATANOTES:1. Data based on sound measurements made in a reverberant room onrepresentati
4650RHR,RVR ELECTRICAL DATALEGEND*Size 006 is available in 50RHR units only.50RHR,RVRUNITVOLTS-PHASE60 HzVOLTAGEMIN/MAXCOMPRESSOR FANMOTORFLATOTALUNIT
4750RHS,RVS ELECTRICAL DATALEGEND50RHS,RVSUNITVOLTS-PHASE60 HzVOLTAG EMIN/MAXCOMPRESSOR FANMOTORFLATOTALUNITFLAMINCIRCUITAMPMAXFUSE/HACRRLA LRA015208/
48Typical piping and wiringThermostatWiringWater InWater OutBall Valve with optional integral P/T plug (typical for supply and return piping)Unit Powe
49Typical wiring schematicsAquazoneThermostatPMStg 1/Stg 2See Note 9*Optional wiring.AL —Alarm Relay ContactsBM —Blower MotorBMC —Blower Motor Capacit
5Model number nomenclature (cont)Airflow Configuration50RHS UnitsCode Return DischargeS Left RightE Left BackZ Right LeftB Right Back50RVS UnitsCode R
50Typical wiring schematics (cont)AquazoneThermostatPMAL —Alarm Relay ContactsBM —Blower MotorBMC —Blower Motor CapacitorCB —Circuit BreakerCC —Compre
51Aquazone™ water source heat pumps may be used inwater loop, ground water, and ground loop type systems.The units are capable of operating with enter
52Water conditioningIn some applications, maintaining proper water qualitymay require the use of higher corrosion protection forwater-to-refrigerant h
53Solenoid valvesIn applications using variable flow pumping, solenoidvalves can be field installed and operated from the controlboard in the Aquazone
54TYPICAL UNIT OPERATING PRESSURES AND TEMPERATURESLEGEND NOTES:1. Based on nominal 400 cfm per ton airflow, 70 F EAT heating and80/67 F EAT cooling.2
55Acoustical design Sound power levels represent the sound as it is producedby the source (e.g., WSHP unit) with no regard to attenua-tion between the
56WSHP sound controlThe analysis of the projected sound level in the conditionedspace caused by a WSHP unit located in a ceiling plenum isquite involv
57Packaged Water Source Heat PumpsHVAC Guide SpecificationsSize Range:50RHR,RVR:6,200 to 59,000 BtuhCooling Capacity7,400 to 68,000 BtuhHeating Capaci
584. The fan motor shall be isolated from the fanhousing by torsionally flexible isolation grom-mets. The fan and motor assembly must becapable of ov
59b. All water connections and electrical knock-outs must be in the compressor compart-ment corner post as to not interfere with theserviceability of
6Factory-installed optionsCupronickel heat exchangers are available for highercorrosion protection for applications such as open tower,geothermal, etc
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.New
7Filter rack (2 in.) is available in place of the standard1-in. return air filter to enhance the filtration system of thewater source heat pump. The 2
8PHYSICAL DATA — AQUAZONE™ 50RHR,RVR006-060 UNITSLEGENDPSC — Permanent Split Capacitor*Size 006 available in 50RHR unit only.NOTES:1. All units have s
950RHR,50RVR WATER LOOP APPLICATIONSLEGENDNOTES:1. A water-to-air heat pump using water or brine circulating in a common pipingloop functioning as a h