9. PROBLEMS
Everything possible has been done to ensure that your unit is the most reliable, trouble-free equipment
available on the market today. If, however, you run into problems, the following section may be of
assistance.
If you do not find the trouble that you have experienced listed below, please call your Carrier
Transicold dealer for assistance.
General problems
Unit won't crank, by the starter
Check battery condition
Check battery connection
Check all fuses
Unit won't start
Check fuel level
Check all fuses
Unit won't run
Check fuel level
Check engine oil level
Check all fuses
Unit dies
Check belts
Check engine oil level
Check coolant level
Check fuel level
Check all fuses
Unit not cooling properly
Defrost unit
Check evaporator for airflow restriction
Check condenser for airflow restriction
Check body for damage or air leaks
9.1. Fuses location
Refer to the electrical schematic provided with the unit.
If a fuse has blown, AL15 FUSE BAD will be displayed. Please contact your Carrier Service Center.
9.2. Fault alarm display and safety features
Display will alternate between an alarm message and the normal display whenever any of the failures
listed below occur.
NOTE : Whenever the fault light is on, check display for fault message.
1. - Reset the micro to start the unit by moving the RUN/STOP switch (4.) to STOP (O) then to RUN
(I).
2. - Press FUNCTION CHANGE key (3.).
3. - Press the UP/DOWN ARROW keys (2.) until ALARM RST is displayed.
4. - Press the ENTER key (17.) to clear alarm. Alarm CLR will now be displayed and unit will restart.