Carrier BW9 Owner's Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
—6—
18 19 20
BW9-50 Through 100 BW9-125 Through 200
8. Replace the front jacket panel.
9. Turn on all electric power to the appliance. (See Fig. 20)
10. Set thermostat to desired setting.
11. If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service technician or gas
supplier.
SHUTTING DOWN YOUR BOILER
Once the heating season has ended, or should you ever suspect a malfunction in your boiler, you will want to turn the boiler off. The following
procedures must be followed:
1. Set the thermostat to lowest setting. (See Fig. 21)
2. Turn off all electric power to the appliance. (See Fig. 22)
3. Remove the front jacket panel.
21 22 23 24
BW9-50 Through 100 BW9-125 Through 200
4. Turn the gas control knob clockwise to “OFF”. Do not force. (See Fig. 23 or 24)
5. Replace the front jacket panel.
PERFORMING ROUTINE MAINTENANCE
With only routine maintenance and care, you can rely on your new boiler to operate economically for many years. Some of the maintenance
you may want to do yourself. However, before performing any service on your boiler, please carefully consider the following:
1. Turn off electrical power supply to your boiler before removing access door to service or perform maintenance.
2. Although special care has been taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into boiler.
COMBUSTION AREA AND VENT SYSTEM
Visually inspect the combustion area and vent system before each heating season. When dirt, soot, scale, or rust builds up, your boiler can lose
efficiency and perform improperly. Accumulations on the main burners can result in the burners firing out of normal sequence. This delayed
ignition will create an alarmingly loud sound.
WARNING: ELECTRICAL SHOCK HAZARD. A failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your boiler before removing the access doors to service or perform maintenance.
CAUTION: UNIT DAMAGE HAZARD. Failure to follow this caution may result in unit component damage. If your
boiler makes an especially loud noise when the main burners light, shut down your boiler and call your dealer.
GAS CONTROL
KNOB SHOWN
IN "ON" POSITION
GAS
INLET
OFF
ON
GAS CONTROL
KNOB SHOWN
IN "ON" POSITION
GAS
INLET
OFF
ON
!
!
Page view 5