36RH,RM,RP,RV COOLING COIL CAPACITIES
PRIMARY AIR NOZZLE ARRANGEMENT
cfm
Capacity
20 F T
(Btuh)
FGHJK
Unit Size
12341234123412341234
15 324
1537
(0.89)
20 432
2022
(1.59)
2080
(0.94)
2098
(0.81)
25 540
2501
(2.48)
2573
(1.47)
2620
(0.97)
2443
(1.26)
2669
(0.74)
30 648
2976
(3.57)
3062
(2.11)
3118
(1.39)
2767
(1.82)
3022
(1.07)
3227
(0.71)
2639
(0.89)
35 756
3546
(2.88)
3611
(1.90)
3592
(1.10)
3074
(2.48)
3357
(1.46)
3585
(0.97)
2902
(1.21)
3204
(0.71)
40 864
4028
(3.76)
4101
(2.48)
4080
(1.44)
3367
(3.24)
3678
(1.91)
3927
(1.26)
4163
(0.73)
3152
(1.58)
3479
(0.94)
2940
(0.92)
45 972
4588
(3.14)
4564
(1.82)
3986
(2.42)
4256
(1.60)
4511
(0.93)
3389
(2.01)
3742
(1.19)
4030
(0.78)
3137
(1.17)
3555
(0.72
)
50 1080
5073
(3.88)
5046
(2.25)
4283
(2.99)
4573
(1.97)
4847
(1.14)
3617
(2.48)
3993
(1.46)
4300
(0.96)
4612
(0.56)
3324
(1.45)
3767
(0.89)
3169
(0.95)
55 1188
5526
(2.72)
4570
(3.62)
4880
(2.39)
5173
(1.39)
3836
(3.00)
4235
(1.77)
4561
(1.17)
4892
(0.68)
3503
(1.75)
3970
(1.07)
4289
(0.68)
3328
(1.15)
60 1296
6004
(3.24)
5179
(2.85)
5489
(1.65)
4048
(3.57)
4469
(2.11)
4812
(1.39)
5162
(0.81)
3674
(2.09)
4164
(1.28)
4499
(0.81)
3479
(1.36)
3939
(0.81)
65 1405
5470
(3.34)
5797
(1.94)
4695
(2.48)
5056
(1.63)
5423
(0.95)
3839
(2.45)
4352
(1.50)
4072
(0.95)
3625
(1.60)
4104
(0.95)
70 1512
6098
(2.25
)
4915
(2.87)
5293
(1.90)
5677
(1.10)
3999
(2.84)
4533
(1.74)
4897
(1.11)
3765
(1.86)
4263
(1.10)
4683
(0.72)
75 1620
6392
(2.58)
5128
(3.30)
5523
(2.18)
5924
(1.26)
4154
(3.26)
4708
(2.00)
5086
(1.27)
5586
(0.75)
3901
(2.13)
4416
(1.26)
4852
(0.83)
80 1730
6680
(2.94)
5337
(3.76)
5747
(2.48)
6164
(1.44)
4304
(3.71)
4878
(2.27)
5270
(1.45)
5788
(0.86)
4032
(2.43)
4564
(1.44)
5015
(0.95)
85 1838
6962
(3.32)
5966
(2.80)
6399
(1.62)
5043
(2.57)
5449
(1.63)
5984
(0.97)
4159
(2.74)
4709
(1.62)
5173
(1.07)
90 1942
6181
(3.14)
6629
(1.82)
5204
(2.88)
5622
(1.83)
6175
(1.09)
4283
(3.06)
4849
(1.82)
5327
(1.20)
5866
(0.69)
95
2055
6390
(3.50)
6854
(2.03)
5361
(3.21)
5792
(2.04)
6361
(1.21)
4403
(3.43)
4985
(2.03)
5746
(1.34)
6030
(0.77)
100 2160
7074
(2.25)
5514
(3.56)
5958
(2.26)
6543
(1.34)
4521
(3.80)
5118
(2.25)
5622
(1.48)
6191
(0.86)
105 2265
7290
(2.48)
5664
(3.92)
6120
(2.50)
6721
(1.48)
5247
(2.48)
5765
(1.63)
6348
(0.95)
110 2375
7503
(2.72)
6278
(2.74)
6895
(1.63)
5374
(2.72)
5904
(1.79)
6501
(1.04)
115 2482
7711
(2.97)
6433
(2.99)
7065
(1.78)
5498
(2.97)
6040
(1.96)
6651
(1.14)
120 2590
7917
(3.24)
6586
(3.26)
7332
(1.94)
5619
(3.24)
6173
(2.13)
6797
(1.24)
125 2700
8119
(3.51)
6735
(3.54)
7396
(2.10)
5378
(3.51)
6303
(2
.32)
6941
(1.34)
130 2810
7558
(2.27)
5854
(3.80)
6431
(2.51)
7082
(1.45)
135 2918
NOTES:
1. Numbers in parenthesis () indicate nozzle pressure (in. wg).
2. Ratings are based on t = 25°F, 1.50 gpm, 8 ft water coil pressure drop.
3. t = t
rm
– t
ew
where t
rm
= room temperature and t
ew
= entering water tempera-
ture.
4. All ratings include allowance for lint screen.
5. For coil capacity at t not equal to 25°F, then use the formula:
( t
rm
– t
ew
)/25 x rating at 25°F t.
6. For primary air capacity at other than 20 F t use the formula:
Btuh = cfm x 1.08 x ( t
rm
– t
pa
) where t
pa
= primary air temperature.
7. For capacities other than 1.50 gpm, see Coil Capacity Multipliers for Flow
Rates table on page 13.
8. To facilitate balanced water systems, all units regardless of size have the
same pressure drop.
7716
(2.45)
6557
(2.70)
7220
(1.57)
140 3022
7872
(2.64)
6680
(2.91)
7356
(1.69)
145 3130
8025
(2.83)
6802
(3.12)
7490
(1.81)
150 3240
8176
(3.03)
6921
(3.34)
7621
(1.94)
155 3350
8325
(3.23)
7038
(3.56)
7750
(2.07)
160 3460
8471
(3.44)
7154
(3.80)
7877
(2.20)
165 3565
8002
(2.34)
170 3675
8126
(2.49)
Performance data (cont)