Carrier 59SP2A User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
SPECIFICATIONS
Heating Capacity and Efficiency 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Input
High
Heat
(BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000
Output
High
Heat
(BTUH) 37,000 37,000 56,000 56,000 75,000 75,000 93,000 111,000
Certified Temperature
Rise Range ºF (ºC)
High Heat
35 - 65
(19 - 36)
35 - 65
(19 - 36)
35 - 65
(19 - 36)
35 - 65
(19 - 36)
40 - 70
(22 - 39)
35 - 65
(19 - 36)
40 - 70
(22 - 39)
45 - 75
(25 - 42)
Airflow Capacity and Blower Data 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Rated External Static
Pressure (in. w.c.)
Heating 0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20
Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Airflow Delivery
@RatedESP(CFM)
High Heat 770 785 1100 1000 1355 1460 1675 1875
Cooling 880 1025 1035 1190 1370 1815 1855 1800
Cooling Capacity (tons)
@ 400, 350 CFM/ton
400 CFM/ton 2 2.5 2.5 3 3.5 4.5 4.5 4.5
350 CFM/ton 2.5 3 3 3.5 4 5 5 5
Direct-Drive Motor Type Electronically Commutated Motor (ECM)
Direct-Drive Motor HP 1/2 1/2 1/2 1/2 1/2 /4 3/4 3/4
Motor Full Load Amps 6.4 6.4 6.4 6.4 6.4 8.8 8.8 8.8
RPM Range 600 - 1200
Speed Selections 5
Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11
Air Filtration System
Factory Supplied Media Cabinet
FieldSuppliedFilter
Filter Used for Certified Watt Data KGAWF1506UFR
Electrical Data 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Input Voltage Volts-Hertz-Phase 115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Input Amps Amps 7 7 7.1 7.1 7.1 9.5 9.6 9.6
Unit Ampacity Amps 9.8 9.8 9.9 9.9 9.9 12.9 12.9 12.9
Minimum Wire Size AWG 14 14 14 14 14 14 14 14
Maximum Wire Length
@ Minimum Wire Size
Feet 38 38 37 37 37 28 28 28
(M) (11.6) (11.6) (11.3) (11.3) (11.3) (8.5) (8.5) (8.5)
Maximum Fuse/Ckt Bkr
(Time-Del ay Type Recommend-
ed)
Amps 15 15 15 15 15 15 15 15
Transfomer Cap acity (24vac output) 40 VA
External C ontrol Power
Available
Heating 27.9 VA
Cooling 34.6 VA
Controls 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Gas Connection Size 1/2” - NPT
Burners (Monoport) 2 2 3 3 4 4 5 6
Gas Valve (Redundant) Manufacturer White Rodgers
Minimum Inlet Gas pressure (in. w.c.) 4.5
Maximum Inlet Gas pressure (in. w.c.) 13.6
Gas Conversion Kit - Natural to Propane KGANP50011SP
Gas Conversion Kit - Propan e to Natural KGAPN42011SP
Manufactured (Mobile) Home Kit KGAMH0601KIT
Ignition Device Silicon Nitride
Limit Control 175 175 205 205 230 185 220 165
Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time D el ay Relay) 90 seconds
Communication System none
Thermostat C onnections Com24V,R,W,G,Y/Y2,DHUM,Y1
Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
* See Accessory List for part numbers available.
59SP2A
Page view 2
1 2 3 4 ... 16

Comments to this Manuals