Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC 111 Catalog No. 535-00091 Printed in U.S.A. Form 50-9SI Pg 1 11-02 Replaces: New
Book 1 4
Ta b 5 a 5 a
Installation, Start-Up and
Configuration Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
PremierLink Controller Hardware. . . . . . . . . . . . . . . . . 1
Field-Supplied Hardware . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPACE TEMPERATURE (SPT) SENSOR
INDOOR AIR QUALITY CO
2
SENSOR
PremierLink Controller Inputs and Outputs . . . . . . 3
Control Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Install Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SPACE TEMPERATURE (SPT) SENSOR
INSTALLATION
INDOOR AIR QUALITY CO
2
SENSOR
INSTALLATION
Connect to CCN Communication Bus . . . . . . . . . . . . 8
COMMUNICATIONS BUS WIRE
SPECIFICATIONS
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8,9
Perform System Check-Out . . . . . . . . . . . . . . . . . . . . . . 8
Initial Operation and Test. . . . . . . . . . . . . . . . . . . . . . . . . 8
Install Navigator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Password Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Forcing Values and Configuring Items . . . . . . . . . . . 9
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-24
Points Display Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Thermostat Control Input Screen. . . . . . . . . . . . . . . . 12
Alarm Service Configuration Screen . . . . . . . . . . . . 12
Controller Identification Screen . . . . . . . . . . . . . . . . . 13
Holiday Configuration Screen . . . . . . . . . . . . . . . . . . . 13
Occupancy Configuration Screen . . . . . . . . . . . . . . . 13
Set Point Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service Configuration Selection Screen. . . . . . . . . 15
PremierLink Configuration Screen . . . . . . . . . . . . . . 18
Occupancy Maintenance Screen . . . . . . . . . . . . . . . . 20
Maintenance Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
SAFETY CONSIDERATIONS
GENERAL
The PremierLink Controller is a factory-installed control
compatible with the Carrier Comfort Network (CCN). This
control is designed to allow users the access and ability to
change factory-defined settings thus expanding the function of
the standard unit control board. The complete PremierLink
package consists of a factory-installed control circuit board
with the Complete C unit controls, leaving water temperature
sensor, and discharge air sensor.
Carriers diagnostic standard tier display tools such as
Navigator or Scrolling Marquee can be used with the Premier-
Link controller. Access is available via an RJ-11 connection or
a 3-wire connection to the communication bus. User interfaces
available for use with the CCN system are PCs equipped with
Carrier user interface software such as Service Tool, Comfort-
VIEW™, or ComfortWORKS®. When used as part of the
CCN, other devices such as the CCN data transfer, Linkage
Thermostat, or Comfort Controller can read data from or write
data to the PremierLink controller.
INSTALLATION
Inspection —
Inspect unit contents for visual defects that
may have occurred during shipping. If there is any damage,
contact your local representative before proceeding.
PremierLink Controller Hardware —
When a CCN
system is installed, a factory-mounted PremierLink controller
is provided with the water source heat pump (WSHP) units.
The package from the factory includes:
PremierLink controller.
Supply air temperature sensor.
Leaving water temperature sensor.
PREMIERLINK CONTROLLER — PremierLink controllers
can be provided with any Aquazone™ water source heat pump
product by selecting this option in the model number nomen-
clature. The PremierLink controller is provided with, and in-
cludes all the features of, the Complete C unit controller. The
specific functionality of PremierLink is described in detail in
dedicated Carrier literature. Factory-supplied wiring (except
space temperature sensor [SPT]) is illustrated in Fig. 1.
SAFETY NOTE
Air-handling equipment will provide safe and reliable service
when operated within design specifications. The equipment
should be operated and serviced only by authorized person-
nel who have a thorough knowledge of system operation,
safety devices and emergency procedures.
Use good judgement when applying any manufacturers
instructions to avoid injury to personnel or damage to equip-
ment and property.
Disconnect all power to the unit before performing mainte-
nance or service. Unit may automatically start if power is
not disconnected. Electrical shock and personal injury
could result.
IMPORTANT: Verify that configurations for AC-HP and
Auxout are correct for proper equipment operation. See
page 18.
PremierLink™
Water Source Heat Pump
Controller
Page view 0
1 2 ... 24

Summary of Contents

Page 1 - Configuration Instructions

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Page 2 - Field-Supplied Hardware —

10CONFIGURATIONThe following sections describe the computer configurationscreens which are used to configure the PremierLink™ con-troller. The screens

Page 3 - Control Wiring —

11ECONOMIZER ACTIVE (NOT USED) — The EconomizerActive point displays the status of the economizer for free cool-ing. When the outdoor conditions matc

Page 4

12INDOOR AIR QUALITY SET POINT — This point dis-plays the current Indoor Air Quality set point. The set point isdetermined by the configured Indoor

Page 5 - FIELD WIRING

13SUPPLY AIR TEMPERATURE — HIGH LIMIT — TheSupply Air Temperature High Limit alarm is used to monitorthe value of the supply air temperature within a

Page 6 - Field Wiring

14OCCUPANCY SCHEDULE — For scheduling flexibility, theoccupancy programming is broken into eight separate periods.For each period the schedule contain

Page 7

15LOW TEMPERATURE MINIMUM POSITION (NOTUSED) — The Low Temperature Minimum Position describesthe low temperature limit for Low Outdoor Air Temperature

Page 8 - Columbia 02525

16STAGED COOLING — The staging function is used for DX(direct expansion) cooling (1 or 2 stages). The staging functionuses the cooling submaster refer

Page 9 - Password Protection —

17SUBMASTER GAIN LIMIT — The Submaster Gain Limitis used to define the submaster gain limit that is multiplied bythe Submaster Error and added to the

Page 10 - Points Display Screen —

18CONTINUOUS POWER EXHAUST (NOT USED) — TheContinuous Power Exhaust function defines the operation ofthe Power Exhaust Fan. If disabled, the Power Ex

Page 11

19Staging occurs as follows for heat pump (AC = 1) units and(AUXOUT = 3) configured for reversing valve:If Heating PID STAGES = 2(HCAP = 50% capacity)

Page 12

2SUPPLY AIR TEMPERATURE SENSOR — A factory-installed supply air temperature sensor is provided withPremierLink™ controller for the water source heat

Page 13

20INDOOR AIR QUALITY PRIORITY LEVEL — The IndoorAir Quality Priority Level, when set to Low, ensures that com-fort is not being compromised by bringin

Page 14 - Set Point Screen —

21MODE — The Mode point displays the current occupiedmode for the controller. If the controller is following its ownlocal schedule this is the result

Page 15 - 2.0 ^F LIMT

22Maintenance Screen — The Maintenance Screen isused to service the PremierLink™ controller. See Table 15.THERMOSTAT CONTROL — Indicates the result

Page 16

23ECONOMIZER SUBMASTER REFERENCE (NOTUSED) — This point displays the supply air temperature deter-mined by the Economizer PID calculation. EconomizerS

Page 17

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Page 18

3PremierLink™ Controller Inputs and Outputs —The PremierLink controller inputs and outputs are shown inTable 1. Control Wiring — The PremierLink contr

Page 19

4Install Sensors (See Fig. 2-6) — The PremierLink™controller can be used with either the T58 Communicating sen-sor or any combination of CO2 and space

Page 20

5INDOOR AIR QUALITY CO2 SENSOR INSTALLATION(IAQ) — The indoor air quality sensor accessory monitorscarbon dioxide (CO2) levels. This information is u

Page 21

6J667REDBLKREDREDBLKBLKBLKREDBLKREDSENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4J667REDBLKREDBLKSENSOR 2SENSOR 1REDREDBLKSENSOR 3SENSOR 4BLKBLKREDREDREDBLKBLKSE

Page 22 - Maintenance Screen —

7Fig. 6 — PremierLink™ Controller and Sensor Wiring — 33ZCT55SPT, 33ZCT56SPT, 33ZCT58SPT Space Temperature Sensors;33ZCSENCO2 (Outdoor), and 33ZCT55CO

Page 23

8Connect to CCN Communication Bus — ThePremierLink™ controller connects to the bus in a daisy chainarrangement. Negative pins on each component must b

Page 24 - Table 15 — Maintenance

9To enter LEN (local equipment network) mode:1. Remove power by removing the connection to J1.2. Remove the connection to J2 (to avoid communicationpr